Method statement · UK
HV switching method statement
An LV-switchgear method is the wrong voltage. If the sequence does not attach the switching schedule and name who may operate, it is not an HV method. This page is not a training course.
Typical scope
- AP and schedule attached
- Compound excluded
- Prove dead as the schedule
- Permit to the working party
- Restore only as written
- Life-safety during the outage
Quick answer
An HV-switching method statement is the sequence for planned switching on a named high-voltage network: authorised person, switching schedule, proving dead, and a building or process that must stay safe in the dark.
Primary topic: hv switching method statement. UK contractors — review every document before you issue it. SafeForJob does not replace competent judgement or HSE guidance.
What usually goes wrong
These are the operational gaps that make generic Word RAMS fail on the next site.
LV board method reused
Wrong voltage, no AP schedule.
Closed a switch because ‘the job looked finished’
Not the schedule.
Compound gate left on the latch
Unauthorised entry.
Example
Planned 11 kV outage for a transformer
Built from one job description. You review and adjust every item before issuing it.
Job description
Switch out TX2 at Elmswell Business Park, Ipswich, Sunday 05:00–14:00. AP with the attached schedule, compound excluded, life-safety lighting agreed, working party on permit, restore only as written.
Activities identified
- General site work
- Electrical isolation
Method (7 steps)
- 1.Arrive and sign in. Arrive at HV compound, Elmswell Business Park, Ipswich, report to the Elmswell Park FM site contact, sign in and complete any site induction.
- 2.Brief the team. Brief all operatives on this RAMS, the COSHH assessments and the emergency arrangements. Record attendance.
- 3.Isolate the electrical supply. Identify the relevant circuit, isolate, lock off and tag. Prove dead with an approved voltage indicator, proved before and after use.
- 4.Carry out electrical work. Carry out the electrical work on the isolated circuit to BS 7671.
- 5.Remove isolation and re-energise. Confirm the work is complete and everyone is clear, remove locks and re-energise.
- 6.Clear up and remove waste. Clear the work area, remove waste from site (including recovered refrigerant and hazardous waste) and leave the area safe.
- 7.Hand over and sign out. Hand over to the Elmswell Park FM site contact, report anything outstanding and sign out.
Main risks (1 in total)
Electric shock or burns
Residual MediumWho: Operatives, building occupants
- Work carried out dead — no live working
- Safe isolation: isolate, lock off, tag, and prove dead with an approved voltage indicator (GS38) proved before and after
- Only competent, qualified electricians carry out electrical work
- Permit to work obtained where the site requires one
- Personal locks and keys retained by the person working
What to get right on this document
The schedule is the method
Attach it.
Only the AP switches
Named.
Restore is written
Not memory.
What this document has to cover
An LV-switchgear method is the wrong voltage. If the sequence does not attach the switching schedule and name who may operate, it is not an HV method. This page is not a training course.
A hv switching method statement only holds up if it names the site, the people at risk, the critical control, and the order of work. Principal contractors reject paragraphs that could apply to any job of this type.
Typical hazards to assess on this job
- Electric shock and arc on HV that was not isolated to the schedule
- Wrong circuit opened so a live network is the one you approached
- Building-wide blackout affecting life-safety
- Stored energy in cables and capacitors
- Unauthorised person in the compound during switching
- Incorrect labelling so the next person switches the wrong device
Likelihood and severity change with occupancy, access, weather and other trades. Copying last month’s scores without looking at this site is how people get hurt.
A method sequence that actually protects people
Write the sequence so the critical control cannot be skipped. If isolation, edge protection or service location is the difference between safe and unsafe, it belongs before the work step — not in a general ‘PPE will be worn’ line.
- Authorised person confirms the schedule, limits of work and alternative supplies
- Exclude the compound; life-safety provisions the client has approved
- Switch, lock, earth and prove dead only as the schedule
- Issue the permit to the working party
- On completion, restore only as the schedule; never ‘just close it’
- Hand over records, remaining defects and updated labels
Occupancy and other people
Hospitals, data halls and care homes lose more than lights. Write who walks the building in the dark and that a cleaner is not allowed in the compound.
Substances and COSHH
An SDS is an input, not a COSHH assessment. If these substances appear on the job, attach assessments that describe quantity, duration, who is exposed and the controls you will actually use:
- Cleaning solvents on compound equipment if used
- Grease on mechanisms
- SF6 only if that equipment is in the visit — specialist method
How SafeForJob helps
- Describe this job in plain English and get suggested activities, risks and method steps
- Edit every line before you download or issue
- Reuse a previous RAMS and catch old client or site names
- Attach or create COSHH assessments where hazardous substances appear
What this page is not
This page is not HSE approval, legal advice or a substitute for competent judgement. It helps you draft a clearer hv switching method statement document for a named job. You remain responsible for reviewing and issuing it.
Related reading
See what a RAMS is, the free RAMS generator, and HSE guidance on managing risks.
Related pages
- RAMS by jobSubstation LV board RAMSCreate a substation lv board rams for a named UK site. Unique hazards, method sequence and occupancy notes you review before issue.
- GuidesHow to write a method statementA practical sequence for writing a method statement that a principal contractor will actually read.
- RAMS by tradeElectrical RAMSCreate a site-specific electrical RAMS online. Describe the job, review suggested risks like safe isolation and work at height, and download a professional PDF.
- Method statementsMethod statement for electrical worksWrite a method statement for electrical works for a named UK site. Clear sequence, interfaces and controls — review before issue.
- Method statementsHVAC installation method statementWrite a hvac installation method statement for a named UK site. Clear sequence, interfaces and controls — review before issue.
- Method statementsPlumbing method statementWrite a plumbing method statement for a named UK site. Clear sequence, interfaces and controls — review before issue.
- Method statementsRoofing method statementWrite a roofing method statement for a named UK site. Clear sequence, interfaces and controls — review before issue.
- Method statementsExcavation method statementWrite a excavation method statement for a named UK site. Clear sequence, interfaces and controls — review before issue.
- Method statementsFit-out method statementWrite a fit out method statement for a named UK site. Clear sequence, interfaces and controls — review before issue.
Questions
- Is this LV switchgear replacement?
- Different voltage and competence. Use this for HV switching.
- Who is the authorised person?
- Name them — the method should not assume a card in the van.
- Can we run on the generator?
- Only if the changeover is designed and isolated from the work. Write it.
- Is this legal advice on the Electricity at Work Regulations?
- No. Follow the network’s safety rules.