RAMS by trade · UK
Electrical RAMS
Create a site-specific electrical RAMS online. Describe the job, review suggested risks and method steps, and download a professional PDF.
Typical scope
- Consumer unit replacement
- Rewires and alterations
- Lighting upgrades
- EV charger installation
- EICRs and testing
- Containment and cabling
Most electrical RAMS cover the same core: safe isolation, access, dust and working around other people. What changes is the site, the circuits and how you get to them.
Quick answer
An electrical RAMS is a site-specific risk assessment and method statement for electrical work. It should cover safe isolation, the people at risk, access, and how the system is tested and restored — written for this job, not a generic trade template.
Primary topic: electrical rams template. UK contractors — review every document before you issue it. SafeForJob does not replace competent judgement or HSE guidance.
What usually goes wrong
These are the operational gaps that make generic Word RAMS fail on the next site.
Old client names left in
A reused Word RAMS still names yesterday's site while the method looks plausible.
Isolation buried in the method
Safe isolation and proving dead are the critical controls — they need to be explicit.
Live testing treated as afterthought
EICR and fault-finding risks differ from installation and need their own controls.
Example
Consumer unit replacement in an occupied office
Built from one job description. You review and adjust every item before issuing it.
Job description
Replace the consumer unit and add two new circuits at Ashdown Offices, first floor. Isolate the supply, work from a podium for the ceiling cabling, drill through blockwork for new containment and test before re-energising. Offices stay occupied during the work.
Activities identified
- General site work
- Ladders or stepladders
- Electrical isolation
- Electrical testing
- Manual handling
- Power tools
- Dust-generating work
- Occupied premises or public areas
Method (13 steps)
- 1.Arrive and sign in. Arrive at Ashdown Offices, first floor, report to the Ashdown Property Management site contact, sign in and complete any site induction.
- 2.Brief the team. Brief all operatives on this RAMS, the COSHH assessments and the emergency arrangements. Record attendance.
- 3.Set up the work area. Set up barriers and signage around the work area and keep it clear of other people.
- 4.Isolate the electrical supply. Identify the relevant circuit, isolate, lock off and tag. Prove dead with an approved voltage indicator, proved before and after use.
- 5.Set up access equipment. Inspect and set up the podium or stepladder on firm, level ground in the work area.
- 6.Disconnect and remove existing equipment. Disconnect and remove the existing equipment. Lower or carry it using mechanical aids or team lifts as planned.
- 7.Drill and fix. Mark out, then drill and fix using on-tool dust extraction. Check for hidden cables and pipes before drilling.
- 8.Install new equipment. Position and fix the new equipment to the manufacturer's instructions.
- 9.Carry out electrical work. Carry out the electrical work on the isolated circuit to BS 7671.
- 10.Test and commission. Test and commission the installation. Record results.
- 11.Remove isolation and re-energise. Confirm the work is complete and everyone is clear, remove locks and re-energise.
- 12.Clear up and remove waste. Clear the work area, remove waste from site (including recovered refrigerant and hazardous waste) and leave the area safe.
- 13.Hand over and sign out. Hand over to the Ashdown Property Management site contact, report anything outstanding and sign out.
Main risks (8 in total)
Fall from ladders or stepladders
Residual MediumWho: Operatives
- Use a podium or mobile tower instead of a ladder where the task allows
- Ladders only for short-duration (under 30 minutes), light work with three points of contact
- Ladder inspected before use; industrial-grade (EN 131 professional) only
- Ladder set on firm, level ground and footed or secured
- No overreaching — move the ladder instead
Electric shock or burns
Residual MediumWho: Operatives, building occupants
- Work carried out dead — no live working
- Safe isolation: isolate, lock off, tag, and prove dead with an approved voltage indicator (GS38) proved before and after
- Only competent, qualified electricians carry out electrical work
- Permit to work obtained where the site requires one
- Personal locks and keys retained by the person working
Electric shock during testing
Residual HighWho: Operatives
- Test dead wherever possible; live testing only where essential
- GS38-compliant test leads and probes, inspected before use
- Barriers or screens to prevent others approaching exposed live parts
- Testing carried out by competent persons only
- Insulated gloves and eye protection where there is an arc-flash risk
Manual handling
Residual MediumWho: Operatives
- Use mechanical aids (trolleys, sack trucks, hoists) for heavy items
- Team lifts for items too heavy or awkward for one person
- Route planned and cleared before moving items
- Operatives trained in safe lifting techniques
- Gloves with good grip and safety footwear
+ 4 more risks in the full RAMS.
What to get right on this document
Safe isolation, written down properly
Isolate, lock off, tag and prove dead with an approved voltage indicator (GS38) proved before and after use.
Testing without guesswork
If the job includes EICRs or live testing, suggest the testing risk separately.
Older buildings
Mention a refurb or ceiling void and check the asbestos register before you drill.
Quick answer
An electrical RAMS is a site-specific risk assessment and method statement for electrical work. It should cover safe isolation, the people at risk, access, and how the system is tested and restored — written for this job, not a generic trade template.
What good looks like on a UK site
Most electrical RAMS cover the same core: safe isolation, access, dust and working around other people. What changes is the site, the circuits and how you get to them. Name the site, the people at risk, and the sequence that keeps them safe. Generic paragraphs that could apply anywhere are the first thing a principal contractor rejects.
How SafeForJob helps
- Describe the job in plain English and get suggested activities, risks and method steps
- Edit every line before you download or issue
- Reuse a previous RAMS and catch old client or site names
- Attach or create COSHH assessments where hazardous substances appear
What this page is not
This page is not HSE approval, legal advice or a substitute for competent judgement. It helps you draft a clearer electrical rams template document for a named job. You remain responsible for reviewing and issuing it.
Related reading
See what a RAMS is, the free RAMS generator, and HSE guidance on managing risks.
Related pages
- RAMS by jobConsumer unit replacement RAMSCreate a consumer unit replacement rams for a named UK site. Suggested risks and method steps you review before download or issue.
- Method statementsMethod statement for electrical worksWrite a method statement for electrical works for a named UK site. Clear sequence, interfaces and controls — review before issue.
- GuidesWhat is a RAMS?RAMS means risk assessment and method statement — usually one site-specific pack for a construction or maintenance job. Practical UK guidance for contractors — with links to free tools.
- RAMS by tradeHVAC RAMSCreate HVAC and refrigeration RAMS online: rooftop units, split systems, refrigerant recovery and brazing. Suggested risks and method steps you review before issue.
- RAMS by tradePlumbing RAMSCreate plumbing and heating RAMS online: boiler swaps, pipework, unvented cylinders and drain-downs. Suggested risks and method steps, reviewed by you.
- RAMS by tradeRoofing RAMSCreate a roofing RAMS online covering edge protection, fragile roofs, falling objects and weather. Suggested controls and method you review before issue.
- RAMS by tradeGroundworks RAMSCreate a groundworks or excavation RAMS online: buried services, trench collapse, plant movement and public interface. Review every suggestion before issue.
- RAMS by tradeFit-out RAMSCreate a fit-out or shopfitting RAMS online: partitions, ceilings, dust, occupied premises and out-of-hours work. Reviewed by you before issue.
- RAMS by tradeFire & security RAMSCreate RAMS for fire alarm, CCTV and access control installation: system isolations, ceiling work, occupied buildings. Review every suggestion before issue.
Questions
- What should an electrical RAMS include?
- The job, site and people; hazards (shock, height, dust, other people); controls; step-by-step method including safe isolation; emergency arrangements.
- Can I reuse an electrical RAMS for the next job?
- Yes — before you send it again, check old client and site names and whether the method still matches.
- Is this RAMS approved by the HSE?
- No software can make a RAMS ‘HSE approved’. You review it before you issue it.