Skip to content
SafeForJob

Method statement · UK

Tracker-row lockout method statement

A ground-mount solar method never names unexpected motion and which row is live on DC. Put this hold point first: lock-out of tracker motion before anyone is under the table — occupancy is part of the method, not a footnote.

Typical scope

  • Lock-out of tracker motion before anyone is under the table as a hold point
  • Unexpected motion and which row is live on DC written
  • Exclusion that holds
  • Restore in the dutyholder’s order
  • Named abort
  • Review before issue

Quick answer

A tracker-row lockout method statement is the sequence for working under a solar tracker row on a named UK site. The hold point is lock-out of tracker motion before anyone is under the table. If someone new cannot brief unexpected motion and which row is live on DC from this method, it is not finished.

Primary topic: tracker-row lockout method statement. UK contractors — review every document before you issue it. SafeForJob does not replace competent judgement or HSE guidance.

What usually goes wrong

These are the operational gaps that make generic Word RAMS fail on the next site.

  • ground-mount solar method reused

    No lock-out of tracker motion before anyone is under the table.

  • Hold point buried

    Unexpected motion and which row is live on DC is a step.

  • Occupancy ignored

    The closed row and that a walker will cut the fence.

Example

Tracker-row lockout sequence on a named site

Built from one job description. You review and adjust every item before issuing it.

Job description

Working under a solar tracker row. Hold point: lock-out of tracker motion before anyone is under the table. unexpected motion and which row is live on DC. the closed row and that a walker will cut the fence.

Activities identified

  • General site work
  • Power tools
  • Solar PV and batteries

Method (8 steps)

  1. 1.Arrive and sign in. Arrive at Named UK site on the pack, report to the Dutyholder on the pack site contact, sign in and complete any site induction.
  2. 2.Brief the team. Brief all operatives on this RAMS, the COSHH assessments and the emergency arrangements. Record attendance.
  3. 3.Drill and fix. Mark out, then drill and fix using on-tool dust extraction. Check for hidden cables and pipes before drilling.
  4. 4.Install mounting system and modules. Fix the mounting system to the roof structure, then install modules. Keep DC isolators open.
  5. 5.Connect inverter and DC strings. Install the inverter and AC connection, then connect DC strings last with isolators open.
  6. 6.Test and commission. Test and commission the installation. Record results.
  7. 7.Clear up and remove waste. Clear the work area, remove waste from site (including recovered refrigerant and hazardous waste) and leave the area safe.
  8. 8.Hand over and sign out. Hand over to the Dutyholder on the pack site contact, report anything outstanding and sign out.

Main risks (3 in total)

Hand and power tools

Residual Low

Who: Operatives

  • Battery or 110V tools used; no 230V tools on site without RCD protection
  • Tools inspected before use and PAT tested where applicable
  • Guards fitted and used as designed
  • Eye protection and gloves suitable for the task

Noise and hand-arm vibration

Residual Medium

Who: Operatives, people nearby

  • Low-vibration, low-noise tools selected
  • Trigger times limited and rotated between operatives
  • Noisy work scheduled to reduce disruption to occupants
  • Hearing protection worn where noise is high

DC electric shock and arc (solar PV / batteries)

Residual High

Who: Installers

  • DC strings connected last; isolators open during installation
  • Never make or break DC connectors under load
  • Modules covered where practical when working on DC wiring
  • Installers competent in PV/battery installation (e.g. MCS-aligned training)
  • Insulated tools and gloves

What to get right on this document

Hold point first

Put this hold point first: lock-out of tracker motion before anyone is under the table.

Name the site facts

Unexpected motion and which row is live on DC

People who did not read it

Farms stay open

What this document has to cover

A ground-mount solar method never names unexpected motion and which row is live on DC. Put this hold point first: lock-out of tracker motion before anyone is under the table — occupancy is part of the method, not a footnote.

A tracker-row lockout method statement only holds up if it names the site, the people at risk, the critical control, and the order of work. Principal contractors reject paragraphs that could apply to any job of this type.

Typical hazards to assess on this job

  • Unexpected tracker motion
  • DC shock on a live string
  • Crush under a moving table
  • Other trades walking the row
  • Energising while someone is still under
  • Weather exceeding the lock method

Likelihood and severity change with occupancy, access, weather and other trades. Copying last month’s scores without looking at this site is how people get hurt.

A method sequence that actually protects people

Write the sequence so the critical control cannot be skipped. If isolation, edge protection or service location is the difference between safe and unsafe, it belongs before the work step — not in a general ‘PPE will be worn’ line.

  • Lock tracker motion; prove it cannot move
  • Isolate named DC strings if the task requires it
  • Set the row exclusion
  • Do the work
  • Clear the row before restore
  • Named person energises

Occupancy and other people

Farms stay open. Write the closed row and that a walker will cut the fence as a method step.

Substances and COSHH

An SDS is an input, not a COSHH assessment. If these substances appear on the job, attach assessments that describe quantity, duration, who is exposed and the controls you will actually use:

  • Substances actually used on this sequence
  • Cleaning agents of the protocol
  • Residues you open

How SafeForJob helps

  • Describe this job in plain English and get suggested activities, risks and method steps
  • Edit every line before you download or issue
  • Reuse a previous RAMS and catch old client or site names
  • Attach or create COSHH assessments where hazardous substances appear

What this page is not

This page is not HSE approval, legal advice or a substitute for competent judgement. It helps you draft a clearer tracker-row lockout method statement document for a named job. You remain responsible for reviewing and issuing it.

Related reading

See what a RAMS is, the free RAMS generator, and HSE guidance on managing risks.

Related pages

All method statements · RAMS by trade · Free RAMS generator

Questions

Is this instead of the tracker-row lockout RAMS?
No — it is the occupancy and sequence layer the job RAMS must include or attach.
Can we skip lock-out of tracker motion before anyone is under the table?
No. Lock-out of tracker motion before anyone is under the table is why this method exists.
Who owns unexpected motion and which row is live on DC?
The dutyholder named on the method. A poster is not a brief.
Can AI issue this method?
A tool can draft a tracker-row lockout method. A competent person reviews it for this site.