Skip to content
SafeForJob

Method statement · UK

Rainscreen cladding method statement

A decorating or EWI method that never names bracket rails, cavity barriers or combustible storage on a live elevation will fail the fire engineer and the clerk of works.

Typical scope

  • Specified system
  • Cavity barriers as you go
  • Board store off the escape
  • Public exclusion
  • Wind abort
  • Resident doors kept

Quick answer

A rainscreen-cladding method statement is the sequence for installing a specified rainscreen on a named elevation: system order, fire of stored boards, exclusion below and weather abort on large panels.

Primary topic: rainscreen cladding method statement. UK contractors — review every document before you issue it. SafeForJob does not replace competent judgement or HSE guidance.

What usually goes wrong

These are the operational gaps that make generic Word RAMS fail on the next site.

  • EWI method reused

    No rails, no barriers.

  • PIR in the stair

    Fire load.

  • Barriers 'snagged for later'

    Strategy open.

Example

Street elevation rainscreen on occupied flats

Built from one job description. You review and adjust every item before issuing it.

Job description

Install specified aluminium rainscreen on Block C, Harbour View, Plymouth. Independent scaffold, mineral-wool barriers as drawn, panel store in a fenced bay, pavement management, residents using rear access, wind abort 25 mph.

Activities identified

  • General site work
  • Mobile tower or scaffold
  • Manual handling
  • Occupied premises or public areas

Method (8 steps)

  1. 1.Arrive and sign in. Arrive at Block C, Harbour View, Plymouth, report to the Harbour View HA site contact, sign in and complete any site induction.
  2. 2.Brief the team. Brief all operatives on this RAMS, the COSHH assessments and the emergency arrangements. Record attendance.
  3. 3.Set up the work area. Set up barriers and signage around the work area and keep it clear of other people.
  4. 4.Erect the tower. PASMA-trained operatives erect the mobile tower to the manufacturer's guide and inspect it before use.
  5. 5.Disconnect and remove existing equipment. Disconnect and remove the existing equipment. Lower or carry it using mechanical aids or team lifts as planned.
  6. 6.Install new equipment. Position and fix the new equipment to the manufacturer's instructions.
  7. 7.Clear up and remove waste. Clear the work area, remove waste from site (including recovered refrigerant and hazardous waste) and leave the area safe.
  8. 8.Hand over and sign out. Hand over to the Harbour View HA site contact, report anything outstanding and sign out.

Main risks (4 in total)

Fall from tower or scaffold, or collapse

Residual Medium

Who: Operatives, people nearby

  • Mobile towers erected by PASMA-trained persons to the manufacturer's guide
  • Scaffold erected by a competent scaffolder and tagged/inspected before use and every 7 days
  • Guard rails, toe boards and brick guards in place on working platforms
  • Castors locked and outriggers fitted; never moved while occupied

Falling objects

Residual Low

Who: People below, other trades, public

  • Exclusion zone set up below the work area with barriers and signage
  • Tools tethered when working at height; materials kept away from edges
  • Banksman or second person controls the area during lifts and removals
  • Hard hats worn in the exclusion zone

Manual handling

Residual Medium

Who: Operatives

  • Use mechanical aids (trolleys, sack trucks, hoists) for heavy items
  • Team lifts for items too heavy or awkward for one person
  • Route planned and cleared before moving items
  • Operatives trained in safe lifting techniques
  • Gloves with good grip and safety footwear

Members of the public and building occupants

Residual Low

Who: Public, customers, staff, residents

  • Work area segregated with barriers and clear signage
  • Work timed for quieter periods where possible, agreed with the site
  • Tools and materials never left unattended in public areas
  • Site contact informed of work areas and any disruption

What to get right on this document

Name the system

Brackets, barriers, panels.

Barriers are a step

Photograph them.

Storage is a control

Not the hallway.

What this document has to cover

A decorating or EWI method that never names bracket rails, cavity barriers or combustible storage on a live elevation will fail the fire engineer and the clerk of works.

A rainscreen cladding method statement only holds up if it names the site, the people at risk, the critical control, and the order of work. Principal contractors reject paragraphs that could apply to any job of this type.

Typical hazards to assess on this job

  • Falls from scaffold or MEWP
  • Fire of stored insulation or combustible rainscreen
  • Panels and tools falling onto the public
  • Cavity barriers missed so the fire strategy fails
  • Wind on large cassettes
  • Residents using doors through the working elevation

Likelihood and severity change with occupancy, access, weather and other trades. Copying last month’s scores without looking at this site is how people get hurt.

A method sequence that actually protects people

Write the sequence so the critical control cannot be skipped. If isolation, edge protection or service location is the difference between safe and unsafe, it belongs before the work step — not in a general ‘PPE will be worn’ line.

  • Inspect access; set exclusion and a non-combustible store off the escape
  • Fix rails and brackets to the specified grid; cavity barriers as you go
  • Hang panels to the system; do not stockpile on the lift
  • Weather abort when the wind makes a cassette a sail
  • Keep resident doors and meters accessible
  • Waste daily; photograph barriers before they disappear

Occupancy and other people

Social-housing streets stay lived in. Meter readers, pushchairs and emergency access through the elevation are method issues, not programme notes.

Substances and COSHH

An SDS is an input, not a COSHH assessment. If these substances appear on the job, attach assessments that describe quantity, duration, who is exposed and the controls you will actually use:

  • Insulation specified for the system
  • Sealants and tapes
  • Adhesives if used

How SafeForJob helps

  • Describe this job in plain English and get suggested activities, risks and method steps
  • Edit every line before you download or issue
  • Reuse a previous RAMS and catch old client or site names
  • Attach or create COSHH assessments where hazardous substances appear

What this page is not

This page is not HSE approval, legal advice or a substitute for competent judgement. It helps you draft a clearer rainscreen cladding method statement document for a named job. You remain responsible for reviewing and issuing it.

Related reading

See what a RAMS is, the free RAMS generator, and HSE guidance on managing risks.

Related pages

All method statements · RAMS by trade · Free RAMS generator

Questions

Is this EWI?
Different system. Rainscreen has a ventilated cavity and barriers — write those.
Cladding remediation?
Follow the specified system and the fire strategy; this page does not substitute a different board.
Who photographs barriers?
The installer, before they are covered.
MEWP instead of scaffold?
Name the machine, ground and exclusion.