Skip to content
SafeForJob

Method statement · UK

Laboratory works method statement

An office fit-out method never mentions a fume cupboard you must not switch off, a mercury trap in an old sink, or a live adjacent suite. If the sequence does not start with decontamination status, it is not a lab method.

Typical scope

  • Decon status written
  • Services on the permit only
  • Extract status named
  • Protocol waste
  • Door locked after clean
  • Lab manager release

Quick answer

A laboratory method statement is the sequence for altering benches, services or finishes in a named lab: residual chemicals, extract left running or isolated on purpose, and a quality or safety officer who can abort.

Primary topic: laboratory method statement. UK contractors — review every document before you issue it. SafeForJob does not replace competent judgement or HSE guidance.

What usually goes wrong

These are the operational gaps that make generic Word RAMS fail on the next site.

  • Office method reused

    No decon, no extract.

  • Cupboard switched off to 'stop the noise'

    Containment lost.

  • Street boots after wipe-down

    Failed room.

Example

Bench swap in a teaching lab

Built from one job description. You review and adjust every item before issuing it.

Job description

Replace two benches in Lab 3, Kingsmead Sixth Form, Bath. Holiday shutdown, decon certificate on the pack, gas and DI isolated, extract left running, protocol clean, lab technician release before term.

Activities identified

  • General site work
  • Manual handling

Method (6 steps)

  1. 1.Arrive and sign in. Arrive at Lab 3, Kingsmead Sixth Form, Bath, report to the Kingsmead Sixth Form site contact, sign in and complete any site induction.
  2. 2.Brief the team. Brief all operatives on this RAMS, the COSHH assessments and the emergency arrangements. Record attendance.
  3. 3.Disconnect and remove existing equipment. Disconnect and remove the existing equipment. Lower or carry it using mechanical aids or team lifts as planned.
  4. 4.Install new equipment. Position and fix the new equipment to the manufacturer's instructions.
  5. 5.Clear up and remove waste. Clear the work area, remove waste from site (including recovered refrigerant and hazardous waste) and leave the area safe.
  6. 6.Hand over and sign out. Hand over to the Kingsmead Sixth Form site contact, report anything outstanding and sign out.

Main risks (1 in total)

Manual handling

Residual Medium

Who: Operatives

  • Use mechanical aids (trolleys, sack trucks, hoists) for heavy items
  • Team lifts for items too heavy or awkward for one person
  • Route planned and cleared before moving items
  • Operatives trained in safe lifting techniques
  • Gloves with good grip and safety footwear

What to get right on this document

Decon first

Do not strip a live bench.

Extract is a control

On or off as the dutyholder wrote.

The lab manager opens the door

Not the carpenter.

What this document has to cover

An office fit-out method never mentions a fume cupboard you must not switch off, a mercury trap in an old sink, or a live adjacent suite. If the sequence does not start with decontamination status, it is not a lab method.

A laboratory method statement only holds up if it names the site, the people at risk, the critical control, and the order of work. Principal contractors reject paragraphs that could apply to any job of this type.

Typical hazards to assess on this job

  • Residual process chemicals or biologicals in sinks, ducts and benches
  • Fume-cupboard extract isolated by mistake
  • Gas, vacuum or DI water left live
  • Glass and sharps in a 'clean' void
  • Fire strategy of a lab corridor blocked by stillages
  • People re-entering in street clothes after a controlled clean

Likelihood and severity change with occupancy, access, weather and other trades. Copying last month’s scores without looking at this site is how people get hurt.

A method sequence that actually protects people

Write the sequence so the critical control cannot be skipped. If isolation, edge protection or service location is the difference between safe and unsafe, it belongs before the work step — not in a general ‘PPE will be worn’ line.

  • Confirm decontamination status and which adjacent rooms stay live
  • Isolate only the services on the permit; keep extract if the dutyholder requires it
  • Strip or install with the specified materials; bag contaminated waste as directed
  • Do not use the room AHU as a dryer
  • Clean-down to the protocol; lock the door
  • Safety officer or lab manager opens the room

Occupancy and other people

Teaching labs and hospital pathology stay in timetable. Write the sealed door and that a student will return at 09:00 whether the silicone is cured or not.

Substances and COSHH

An SDS is an input, not a COSHH assessment. If these substances appear on the job, attach assessments that describe quantity, duration, who is exposed and the controls you will actually use:

  • Residual process chemicals (treat as unknown until the lab list says otherwise)
  • Specified sealants and adhesives
  • Cleaning agents of the protocol

How SafeForJob helps

  • Describe this job in plain English and get suggested activities, risks and method steps
  • Edit every line before you download or issue
  • Reuse a previous RAMS and catch old client or site names
  • Attach or create COSHH assessments where hazardous substances appear

What this page is not

This page is not HSE approval, legal advice or a substitute for competent judgement. It helps you draft a clearer laboratory method statement document for a named job. You remain responsible for reviewing and issuing it.

Related reading

See what a RAMS is, the free RAMS generator, and HSE guidance on managing risks.

Related pages

All method statements · RAMS by trade · Free RAMS generator

Questions

Is this a cleanroom method?
Related discipline, different air class and validation. Use this for labs that are not classified rooms.
Mercury in old traps?
Stop and get advice — do not pour a trap to a drain.
Who owns the chemical list?
The lab — you do not guess residues.
Can AI issue this method?
A tool can draft. A competent person reviews it for this room.