Method statement · UK
Kitchen fitting method statement
If gas isolation is not a step, it will be skipped.
Typical scope
- Isolation
- Stone controls
- Handling
- Tests
- Relight competence
- Waste
Quick answer
A kitchen fitting method statement is the sequence from isolation through strip, units, worktops and tests. Services and silica should appear as steps, not footnotes.
Primary topic: kitchen fitting method statement. UK contractors — review every document before you issue it. SafeForJob does not replace competent judgement or HSE guidance.
What usually goes wrong
These are the operational gaps that make generic Word RAMS fail on the next site.
No isolation step
Live services.
Indoor dry stone cut
Silica.
No relight
Occupier unsafe.
Example
Domestic refit
Built from one job description. You review and adjust every item before issuing it.
Job description
Occupied house, quartz wet-cut outdoors, family upstairs.
Activities identified
- General site work
- Power tools
- Occupied premises or public areas
- Outdoor or exposed work
Method (6 steps)
- 1.Arrive and sign in. Arrive at Occupied kitchen, report to the Homeowner site contact, sign in and complete any site induction.
- 2.Brief the team. Brief all operatives on this RAMS, the COSHH assessments and the emergency arrangements. Record attendance.
- 3.Set up the work area. Set up barriers and signage around the work area and keep it clear of other people.
- 4.Drill and fix. Mark out, then drill and fix using on-tool dust extraction. Check for hidden cables and pipes before drilling.
- 5.Clear up and remove waste. Clear the work area, remove waste from site (including recovered refrigerant and hazardous waste) and leave the area safe.
- 6.Hand over and sign out. Hand over to the Homeowner site contact, report anything outstanding and sign out.
Main risks (4 in total)
Hand and power tools
Residual LowWho: Operatives
- Battery or 110V tools used; no 230V tools on site without RCD protection
- Tools inspected before use and PAT tested where applicable
- Guards fitted and used as designed
- Eye protection and gloves suitable for the task
Noise and hand-arm vibration
Residual MediumWho: Operatives, people nearby
- Low-vibration, low-noise tools selected
- Trigger times limited and rotated between operatives
- Noisy work scheduled to reduce disruption to occupants
- Hearing protection worn where noise is high
Members of the public and building occupants
Residual LowWho: Public, customers, staff, residents
- Work area segregated with barriers and clear signage
- Work timed for quieter periods where possible, agreed with the site
- Tools and materials never left unattended in public areas
- Site contact informed of work areas and any disruption
Adverse weather
Residual LowWho: Operatives
- Forecast checked before work; work at height stopped in high winds
- Breaks, water and shade in hot weather; warm clothing in cold
- Sun protection on exposed work in summer
What to get right on this document
Prove dead / isolate gas
Named competence.
Cut outdoors or wet
Silica.
Tests
Water, electric, gas.
What this document has to cover
If gas isolation is not a step, it will be skipped.
A kitchen fitting method statement only holds up if it names the site, the people at risk, the critical control, and the order of work. Principal contractors reject paragraphs that could apply to any job of this type.
Typical hazards to assess on this job
- Services
- Silica
- Stairs
- Occupier
- Leaks
Likelihood and severity change with occupancy, access, weather and other trades. Copying last month’s scores without looking at this site is how people get hurt.
A method sequence that actually protects people
Write the sequence so the critical control cannot be skipped. If isolation, edge protection or service location is the difference between safe and unsafe, it belongs before the work step — not in a general ‘PPE will be worn’ line.
- Isolate/prove
- Protect home
- Strip
- First fix
- Units
- Worktops with cutting controls
- Test/relight
- Handover
Occupancy and other people
Family in the house: keep a route, no live tails over lunch.
Substances and COSHH
An SDS is an input, not a COSHH assessment. If these substances appear on the job, attach assessments that describe quantity, duration, who is exposed and the controls you will actually use:
- Silica
- Silicone
- Foam
How SafeForJob helps
- Describe this job in plain English and get suggested activities, risks and method steps
- Edit every line before you download or issue
- Reuse a previous RAMS and catch old client or site names
- Attach or create COSHH assessments where hazardous substances appear
What this page is not
This page is not HSE approval, legal advice or a substitute for competent judgement. It helps you draft a clearer kitchen fitting method statement document for a named job. You remain responsible for reviewing and issuing it.
Related reading
See what a RAMS is, the free RAMS generator, and HSE guidance on managing risks.
Related pages
- RAMS by tradeKitchen fitter RAMSRAMS for kitchen fitting: services isolation, stone silica, stairs and residents.
- RAMS by jobKitchen fitting RAMSCreate a kitchen fitting rams for a named UK site. Unique hazards, method sequence and occupancy notes you review before issue.
- GuidesRAMS vs method statementHow the risk assessment and method statement fit together, and when clients ask for a combined RAMS. Practical UK guidance for contractors — with links to free tools.
- Method statementsMethod statement for electrical worksWrite a method statement for electrical works for a named UK site. Clear sequence, interfaces and controls — review before issue.
- Method statementsHVAC installation method statementWrite a hvac installation method statement for a named UK site. Clear sequence, interfaces and controls — review before issue.
- Method statementsPlumbing method statementWrite a plumbing method statement for a named UK site. Clear sequence, interfaces and controls — review before issue.
- Method statementsRoofing method statementWrite a roofing method statement for a named UK site. Clear sequence, interfaces and controls — review before issue.
- Method statementsExcavation method statementWrite a excavation method statement for a named UK site. Clear sequence, interfaces and controls — review before issue.
- Method statementsFit-out method statementWrite a fit out method statement for a named UK site. Clear sequence, interfaces and controls — review before issue.
Questions
- Commercial?
- Add nights and grease.
- Who isolates gas?
- Gas Safe.
- Appliances via stairs?
- Write the route.
- Waste?
- Same day.