RAMS by job · UK
Scissor-dock service RAMS
This is not a dock leveller RAMS. This job covers servicing a scissor dock leveller on a live bay, and the control that keeps people safe is lock-off of the ram and a closed-bay plan before anyone is under the plate. If the RAMS never names unexpected motion, HGVs and who holds the key, a principal contractor will send it back.
Typical scope
- Lock-off of the ram and a closed-bay plan before anyone is under the plate as a hold point
- Unexpected motion, HGVs and who holds the key named
- Exclusion that actually holds
- Sequence that cannot skip the critical control
- Handover of residual hazards
- Review before issue — not a stamp
Quick answer
A scissor-dock service rams covers servicing a scissor dock leveller on a live bay on a named UK site. The critical control is lock-off of the ram and a closed-bay plan before anyone is under the plate. Write unexpected motion, HGVs and who holds the key into the sequence — a pack that could describe any dock leveller RAMS will not survive a competent review.
Primary topic: scissor-dock service rams. UK contractors — review every document before you issue it. SafeForJob does not replace competent judgement or HSE guidance.
What usually goes wrong
These are the operational gaps that make generic Word RAMS fail on the next site.
dock leveller RAMS reused
No lock-off of the ram and a closed-bay plan before anyone is under the plate.
Critical control buried
Unexpected motion, HGVs and who holds the key belongs in the sequence.
Occupancy ignored
Unexpected motion, HGVs and who holds the key and that someone who did not read the pack will walk the exclusion.
Example
Scissor-dock service on a named site
Built from one job description. You review and adjust every item before issuing it.
Job description
Servicing a scissor dock leveller on a live bay at Block C, Ripon Close, Ripon. Holiday week, staff return Friday. Lock-off of the ram and a closed-bay plan before anyone is under the plate; unexpected motion, HGVs and who holds the key; unexpected motion, HGVs and who holds the key and that someone who did not read the pack will walk the exclusion.
Activities identified
- General site work
- Electrical isolation
Method (7 steps)
- 1.Arrive and sign in. Arrive at Block C, Ripon Close, Ripon, report to the Ripon Close Housing site contact, sign in and complete any site induction.
- 2.Brief the team. Brief all operatives on this RAMS, the COSHH assessments and the emergency arrangements. Record attendance.
- 3.Isolate the electrical supply. Identify the relevant circuit, isolate, lock off and tag. Prove dead with an approved voltage indicator, proved before and after use.
- 4.Carry out electrical work. Carry out the electrical work on the isolated circuit to BS 7671.
- 5.Remove isolation and re-energise. Confirm the work is complete and everyone is clear, remove locks and re-energise.
- 6.Clear up and remove waste. Clear the work area, remove waste from site (including recovered refrigerant and hazardous waste) and leave the area safe.
- 7.Hand over and sign out. Hand over to the Ripon Close Housing site contact, report anything outstanding and sign out.
Main risks (1 in total)
Electric shock or burns
Residual MediumWho: Operatives, building occupants
- Work carried out dead — no live working
- Safe isolation: isolate, lock off, tag, and prove dead with an approved voltage indicator (GS38) proved before and after
- Only competent, qualified electricians carry out electrical work
- Permit to work obtained where the site requires one
- Personal locks and keys retained by the person working
What to get right on this document
Critical control first
Put this hold point first: lock-off of the ram and a closed-bay plan before anyone is under the plate.
Name the site facts
Unexpected motion, HGVs and who holds the key
People who did not read the pack
The named site stays in use around this scissor-dock service job
What this document has to cover
This is not a dock leveller RAMS. This job covers servicing a scissor dock leveller on a live bay, and the control that keeps people safe is lock-off of the ram and a closed-bay plan before anyone is under the plate. If the RAMS never names unexpected motion, HGVs and who holds the key, a principal contractor will send it back.
A scissor-dock service rams only holds up if it names the site, the people at risk, the critical control, and the order of work. Principal contractors reject paragraphs that could apply to any job of this type.
Typical hazards to assess on this job
- People hurt if lock-off of the ram and a closed-bay plan before anyone is under the plate is skipped on this scissor-dock service job
- Scissor-dock service left open so a passer-by reaches the hazard
- Wrong isolation so a sister scissor-dock service stays live
- Manual handling or dropped parts on this scissor-dock service job
- Weather, dust or a substance unique to servicing a scissor dock leveller on a live bay
- The next crew inheriting an open scissor-dock service hazard because handover was a text to nobody
Likelihood and severity change with occupancy, access, weather and other trades. Copying last month’s scores without looking at this site is how people get hurt.
A method sequence that actually protects people
Write the sequence so the critical control cannot be skipped. If isolation, edge protection or service location is the difference between safe and unsafe, it belongs before the work step — not in a general ‘PPE will be worn’ line.
- Hold point: lock-off of the ram and a closed-bay plan before anyone is under the plate
- Brief the dutyholder on unexpected motion, HGVs and who holds the key
- Set an exclusion that matches dock leveller RAMS failing on this site
- Do the work to the sequence that keeps lock-off of the ram and a closed-bay plan before anyone is under the plate first
- Test or prove the critical control still holds
- Handover residual scissor-dock service hazards in writing
Occupancy and other people
The named site stays in use around this scissor-dock service job. Write unexpected motion, HGVs and who holds the key and that someone who did not read the pack will walk the exclusion as occupancy control, not a hope.
Substances and COSHH
An SDS is an input, not a COSHH assessment. If these substances appear on the job, attach assessments that describe quantity, duration, who is exposed and the controls you will actually use:
- Substances used while servicing a scissor dock leveller on a live bay
- Cleaning wipes specified for the finish
- Dust or residue from the opened plant
How SafeForJob helps
- Describe this job in plain English and get suggested activities, risks and method steps
- Edit every line before you download or issue
- Reuse a previous RAMS and catch old client or site names
- Attach or create COSHH assessments where hazardous substances appear
What this page is not
This page is not HSE approval, legal advice or a substitute for competent judgement. It helps you draft a clearer scissor-dock service rams document for a named job. You remain responsible for reviewing and issuing it.
Related reading
See what a RAMS is, the free RAMS generator, and HSE guidance on managing risks.
Related pages
- RAMS by tradeFacilities maintenance RAMSCreate ppm method statement online for UK sites. Suggested risks and method steps matched to the job — you review every item before issue.
- GuidesWhat is a RAMS?RAMS means risk assessment and method statement — usually one site-specific pack for a construction or maintenance job. Practical UK guidance for contractors — with links to free tools.
- Method statementsWarehouse works method statementWrite a warehouse method statement for a named UK site. Clear sequence, interfaces and controls — review before issue.
- RAMS by jobConsumer unit replacement RAMSCreate a consumer unit replacement rams for a named UK site. Suggested risks and method steps you review before download or issue.
- RAMS by jobEV charger installation RAMSCreate a ev charger installation rams for a named UK site. Suggested risks and method steps you review before download or issue.
- RAMS by jobLighting rewire RAMSCreate a lighting rewire rams for a named UK site. Suggested risks and method steps you review before download or issue.
- RAMS by jobEICR testing RAMSCreate a eicr method statement for a named UK site. Suggested risks and method steps you review before download or issue.
- RAMS by jobRooftop condenser replacement RAMSCreate a rooftop ac unit replacement rams for a named UK site. Suggested risks and method steps you review before download or issue.
- RAMS by jobSplit system installation RAMSCreate a split system installation rams for a named UK site. Suggested risks and method steps you review before download or issue.
Questions
- Is this the same as a dock leveller RAMS?
- No. A scissor-dock service RAMS has to name unexpected motion, HGVs and who holds the key. A dock leveller RAMS will not survive a competent review.
- Can we skip lock-off of the ram and a closed-bay plan before anyone is under the plate?
- No. Lock-off of the ram and a closed-bay plan before anyone is under the plate is the hold point. Write it before the work step.
- Who writes unexpected motion, HGVs and who holds the key?
- The competent person who issues this scissor-dock service rams. A sticky note is not a handover.
- Can AI issue this scissor-dock service rams?
- A tool can draft a scissor-dock service pack. A competent person reviews and issues it for this site.