Skip to content
SafeForJob

RAMS by job · UK

Laboratory fume extract RAMS

This is not a hvac installation RAMS. This job covers altering extract that serves fume cupboards in a named laboratory, and the control that keeps people safe is confirming decontamination status and which cupboards must stay running. If the RAMS never names decon status, which adjacent rooms stay live and who owns the chemical list, a principal contractor will send it back.

Typical scope

  • Decon written
  • Permit branches only
  • Ducts capped
  • Lab manager release
  • Flow test
  • Open branches listed

Quick answer

A fume cupboard extract rams covers altering extract that serves fume cupboards in a named laboratory on a named UK site. The critical control is confirming decontamination status and which cupboards must stay running. Write decon status, which adjacent rooms stay live and who owns the chemical list into the sequence — a pack that could describe any hvac installation RAMS will not survive a competent review.

Primary topic: fume cupboard extract rams. UK contractors — review every document before you issue it. SafeForJob does not replace competent judgement or HSE guidance.

What usually goes wrong

These are the operational gaps that make generic Word RAMS fail on the next site.

  • hvac installation RAMS reused

    No confirming decontamination status and which cupboards must stay running.

  • Critical control buried

    Decon status, which adjacent rooms stay live and who owns the chemical list belongs in the sequence.

  • Occupancy ignored

    The sealed door and that a student returns at 09:00.

Example

Laboratory fume extract on a named site

Built from one job description. You review and adjust every item before issuing it.

Job description

Altering extract that serves fume cupboards in a named laboratory at Lab 3 extract, Kingsmead Sixth Form, Bath. Holiday shutdown, technician release before term. Confirming decontamination status and which cupboards must stay running; decon status, which adjacent rooms stay live and who owns the chemical list; the sealed door and that a student returns at 09:00.

Activities identified

  • General site work
  • Using chemicals or products

Method (5 steps)

  1. 1.Arrive and sign in. Arrive at Lab 3 extract, Kingsmead Sixth Form, Bath, report to the Kingsmead Sixth Form site contact, sign in and complete any site induction.
  2. 2.Brief the team. Brief all operatives on this RAMS, the COSHH assessments and the emergency arrangements. Record attendance.
  3. 3.Apply products. Apply products as described on the Safety Data Sheet and COSHH assessment, with ventilation and the specified PPE.
  4. 4.Clear up and remove waste. Clear the work area, remove waste from site (including recovered refrigerant and hazardous waste) and leave the area safe.
  5. 5.Hand over and sign out. Hand over to the Kingsmead Sixth Form site contact, report anything outstanding and sign out.

Main risks (1 in total)

Hazardous substances

Residual Medium

Who: Operatives, people nearby

  • Use the least hazardous product that does the job
  • COSHH assessment in place for each hazardous substance and briefed to operatives
  • Good ventilation during and after use
  • Substances stored and disposed of as the Safety Data Sheet describes
  • Gloves and eye protection as specified on the SDS

What to get right on this document

Critical control first

Put this hold point first: confirming decontamination status and which cupboards must stay running.

Name the site facts

Decon status, which adjacent rooms stay live and who owns the chemical list

People who did not read the pack

Teaching labs stay on a timetable

What this document has to cover

This is not a hvac installation RAMS. This job covers altering extract that serves fume cupboards in a named laboratory, and the control that keeps people safe is confirming decontamination status and which cupboards must stay running. If the RAMS never names decon status, which adjacent rooms stay live and who owns the chemical list, a principal contractor will send it back.

A fume cupboard extract rams only holds up if it names the site, the people at risk, the critical control, and the order of work. Principal contractors reject paragraphs that could apply to any job of this type.

Typical hazards to assess on this job

  • Residual process chemicals in ducts
  • Cupboard extract isolated by mistake so a lesson continues without containment
  • Fall from a roof fan deck
  • Fire strategy of a lab corridor blocked by stillages
  • Gas or vacuum left live on a bench you thought was dead
  • Students returning at 09:00 to an open duct

Likelihood and severity change with occupancy, access, weather and other trades. Copying last month’s scores without looking at this site is how people get hurt.

A method sequence that actually protects people

Write the sequence so the critical control cannot be skipped. If isolation, edge protection or service location is the difference between safe and unsafe, it belongs before the work step — not in a general ‘PPE will be worn’ line.

  • Confirm decon and which cupboards stay on with the lab manager
  • Isolate only the branches on the permit
  • Do the extract work; cap open ducts
  • Reinstate; smoke or flow-test as the lab requires
  • Lab manager opens the room
  • Hand over remaining open branches

Occupancy and other people

Teaching labs stay on a timetable. Write the sealed door and that a student returns at 09:00 as occupancy control, not a hope.

Substances and COSHH

An SDS is an input, not a COSHH assessment. If these substances appear on the job, attach assessments that describe quantity, duration, who is exposed and the controls you will actually use:

  • Residual process chemicals
  • Specified sealants
  • Roof-fan grease

How SafeForJob helps

  • Describe this job in plain English and get suggested activities, risks and method steps
  • Edit every line before you download or issue
  • Reuse a previous RAMS and catch old client or site names
  • Attach or create COSHH assessments where hazardous substances appear

What this page is not

This page is not HSE approval, legal advice or a substitute for competent judgement. It helps you draft a clearer fume cupboard extract rams document for a named job. You remain responsible for reviewing and issuing it.

Related reading

See what a RAMS is, the free RAMS generator, and HSE guidance on managing risks.

Related pages

All rams by job · RAMS by trade · Free RAMS generator

Questions

Is this a cleanroom method?
Related discipline, different class. Use this for lab extract that is not a classified room.
Mercury in old ducts?
Stop and get advice — do not knock a duct to a skip.
Who owns the chemical list?
The lab. You do not guess residues.
Can a cupboard stay on?
If the dutyholder requires it — write which ones.