RAMS by job · UK
Kitchen canopy installation RAMS
A canopy is a large greasy load over ignition sources. A ductwork RAMS that never mentions the lift over a range, ANSUL interfaces or the chef’s service time will not pass.
Typical scope
- Kitchen closed and ranges isolated
- Canopy lift plan
- Immediate multiple fixings
- Suppression specialist if broken into
- Fire-resisting duct as specified
- Chef briefing
Quick answer
A kitchen canopy installation RAMS covers lifting and connecting a commercial extract canopy: the lift, grease duct interface, fire suppression knock-ons and a kitchen that may still be trading. Height over ranges and grease are the core.
Primary topic: kitchen canopy installation rams. UK contractors — review every document before you issue it. SafeForJob does not replace competent judgement or HSE guidance.
What usually goes wrong
These are the operational gaps that make generic Word RAMS fail on the next site.
Duct RAMS reused
No lift over a range.
Cook-on during the hang
Fire and grease.
ANSUL pipes used as a handle
Suppression broken.
Example
New canopy in a trading hotel kitchen
Built from one job description. You review and adjust every item before issuing it.
Job description
Hang a new extract canopy at Harbourview Hotel, Scarborough, Monday 00:30–07:00. Kitchen closed, ranges isolated, two-person lift from a genie, drop-rods as drawn, suppression contractor on the same permit, chef briefed, no breakfast until signed.
Activities identified
- General site work
- Occupied premises or public areas
Method (5 steps)
- 1.Arrive and sign in. Arrive at Harbourview Hotel, Scarborough, report to the Harbourview Hotel site contact, sign in and complete any site induction.
- 2.Brief the team. Brief all operatives on this RAMS, the COSHH assessments and the emergency arrangements. Record attendance.
- 3.Set up the work area. Set up barriers and signage around the work area and keep it clear of other people.
- 4.Clear up and remove waste. Clear the work area, remove waste from site (including recovered refrigerant and hazardous waste) and leave the area safe.
- 5.Hand over and sign out. Hand over to the Harbourview Hotel site contact, report anything outstanding and sign out.
Main risks (1 in total)
Members of the public and building occupants
Residual LowWho: Public, customers, staff, residents
- Work area segregated with barriers and clear signage
- Work timed for quieter periods where possible, agreed with the site
- Tools and materials never left unattended in public areas
- Site contact informed of work areas and any disruption
What to get right on this document
The canopy is a lift
Plan and isolation of the range.
Suppression is specialist
Do not improvise.
Service waits
Interlocks before cooking.
What this document has to cover
A canopy is a large greasy load over ignition sources. A ductwork RAMS that never mentions the lift over a range, ANSUL interfaces or the chef’s service time will not pass.
A kitchen canopy installation rams only holds up if it names the site, the people at risk, the critical control, and the order of work. Principal contractors reject paragraphs that could apply to any job of this type.
Typical hazards to assess on this job
- Dropped canopy onto people or a live range
- Falls from podiums over a slippery kitchen floor
- Fire if you work over a range that was not isolated
- Breaking into a suppression system without the specialist
- Manual handling through a tight scullery
- Staff still plating under a half-hung canopy
Likelihood and severity change with occupancy, access, weather and other trades. Copying last month’s scores without looking at this site is how people get hurt.
A method sequence that actually protects people
Write the sequence so the critical control cannot be skipped. If isolation, edge protection or service location is the difference between safe and unsafe, it belongs before the work step — not in a general ‘PPE will be worn’ line.
- Agree the kitchen closedown, isolate gas/electric to the ranges, and a lift plan for the canopy
- Protect the floor; set exclusion at the pass
- Lift, hang and level to the design; do not leave it on a single unsecured drop-rod
- Connect duct and make the fire-resisting enclosure as specified
- Coordinate suppression and interlocks — specialist if you break the system
- Degrease the work area; brief the chef on isolation and filters
Occupancy and other people
Restaurants want the pass open at noon. Write the closed hours and that nobody cooks under a canopy that is not yet fixed and interlocked.
Substances and COSHH
An SDS is an input, not a COSHH assessment. If these substances appear on the job, attach assessments that describe quantity, duration, who is exposed and the controls you will actually use:
- Grease and degreasers
- Sealants on duct joints
- Insulation on the fire-resisting wrap
How SafeForJob helps
- Describe this job in plain English and get suggested activities, risks and method steps
- Edit every line before you download or issue
- Reuse a previous RAMS and catch old client or site names
- Attach or create COSHH assessments where hazardous substances appear
What this page is not
This page is not HSE approval, legal advice or a substitute for competent judgement. It helps you draft a clearer kitchen canopy installation rams document for a named job. You remain responsible for reviewing and issuing it.
Related reading
See what a RAMS is, the free RAMS generator, and HSE guidance on managing risks.
Related pages
- RAMS by tradeHVAC RAMSCreate HVAC and refrigeration RAMS online: rooftop units, split systems, refrigerant recovery and brazing. Suggested risks and method steps you review before issue.
- GuidesWhat is a RAMS?RAMS means risk assessment and method statement — usually one site-specific pack for a construction or maintenance job. Practical UK guidance for contractors — with links to free tools.
- Method statementsKitchen fitting method statementSequence for kitchen fitting: services, stone cutting, handling and occupier.
- RAMS by jobConsumer unit replacement RAMSCreate a consumer unit replacement rams for a named UK site. Suggested risks and method steps you review before download or issue.
- RAMS by jobEV charger installation RAMSCreate a ev charger installation rams for a named UK site. Suggested risks and method steps you review before download or issue.
- RAMS by jobLighting rewire RAMSCreate a lighting rewire rams for a named UK site. Suggested risks and method steps you review before download or issue.
- RAMS by jobEICR testing RAMSCreate a eicr method statement for a named UK site. Suggested risks and method steps you review before download or issue.
- RAMS by jobRooftop condenser replacement RAMSCreate a rooftop ac unit replacement rams for a named UK site. Suggested risks and method steps you review before download or issue.
- RAMS by jobSplit system installation RAMSCreate a split system installation rams for a named UK site. Suggested risks and method steps you review before download or issue.
Questions
- Is extract cleaning in this RAMS?
- Only if you clean — otherwise attach that method.
- Gas interlock?
- If you are the one wiring it, write it; competence is shared.
- Can the night porter stay?
- Not in the exclusion under the lift.
- Make-up air?
- If you alter it, add balancing — a canopy that only extracts will smoke the servery.