Skip to content
SafeForJob

RAMS by job · UK

Crash-deck install RAMS

This is not a temporary works propping RAMS. This job covers installing a crash deck or fan to catch falling materials over occupied space, and the control that keeps people safe is a written temporary-works design and a closed-area plan before the first beam is landed. If the RAMS never names what stays occupied below, the design load and who inspects daily, a principal contractor will send it back.

Typical scope

  • A written temporary-works design and a closed-area plan before the first beam is landed as a hold point
  • What stays occupied below, the design load and who inspects daily named
  • Exclusion that actually holds
  • Sequence that cannot skip the critical control
  • Handover of residual hazards
  • Review before issue — not a stamp

Quick answer

A crash-deck install rams covers installing a crash deck or fan to catch falling materials over occupied space on a named UK site. The critical control is a written temporary-works design and a closed-area plan before the first beam is landed. Write what stays occupied below, the design load and who inspects daily into the sequence — a pack that could describe any temporary works propping RAMS will not survive a competent review.

Primary topic: crash-deck install rams. UK contractors — review every document before you issue it. SafeForJob does not replace competent judgement or HSE guidance.

What usually goes wrong

These are the operational gaps that make generic Word RAMS fail on the next site.

  • temporary works propping RAMS reused

    Missing: a written temporary-works design and a closed-area plan before the first beam is landed.

  • Critical control buried

    What stays occupied below, the design load and who inspects daily belongs in the sequence.

  • Occupancy ignored

    The closed floor and that a cleaner will walk under an incomplete fan.

Example

Crash-deck install on a named site

Built from one job description. You review and adjust every item before issuing it.

Job description

Installing a crash deck or fan to catch falling materials over occupied space at Atrium, Civic Annex, Lincoln. Friday 18:00–06:00, atrium closed, offices live above. A written temporary-works design and a closed-area plan before the first beam is landed; what stays occupied below, the design load and who inspects daily; the closed floor and that a cleaner will walk under an incomplete fan.

Activities identified

  • General site work
  • Manual handling
  • Occupied premises or public areas
  • Using chemicals or products

Method (8 steps)

  1. 1.Arrive and sign in. Arrive at Atrium, Civic Annex, Lincoln, report to the Civic Annex FM site contact, sign in and complete any site induction.
  2. 2.Brief the team. Brief all operatives on this RAMS, the COSHH assessments and the emergency arrangements. Record attendance.
  3. 3.Set up the work area. Set up barriers and signage around the work area and keep it clear of other people.
  4. 4.Disconnect and remove existing equipment. Disconnect and remove the existing equipment. Lower or carry it using mechanical aids or team lifts as planned.
  5. 5.Install new equipment. Position and fix the new equipment to the manufacturer's instructions.
  6. 6.Apply products. Apply products as described on the Safety Data Sheet and COSHH assessment, with ventilation and the specified PPE.
  7. 7.Clear up and remove waste. Clear the work area, remove waste from site (including recovered refrigerant and hazardous waste) and leave the area safe.
  8. 8.Hand over and sign out. Hand over to the Civic Annex FM site contact, report anything outstanding and sign out.

Main risks (3 in total)

Manual handling

Residual Medium

Who: Operatives

  • Use mechanical aids (trolleys, sack trucks, hoists) for heavy items
  • Team lifts for items too heavy or awkward for one person
  • Route planned and cleared before moving items
  • Operatives trained in safe lifting techniques
  • Gloves with good grip and safety footwear

Members of the public and building occupants

Residual Low

Who: Public, customers, staff, residents

  • Work area segregated with barriers and clear signage
  • Work timed for quieter periods where possible, agreed with the site
  • Tools and materials never left unattended in public areas
  • Site contact informed of work areas and any disruption

Hazardous substances

Residual Medium

Who: Operatives, people nearby

  • Use the least hazardous product that does the job
  • COSHH assessment in place for each hazardous substance and briefed to operatives
  • Good ventilation during and after use
  • Substances stored and disposed of as the Safety Data Sheet describes
  • Gloves and eye protection as specified on the SDS

What to get right on this document

Critical control first

Put this hold point first: a written temporary-works design and a closed-area plan before the first beam is landed.

Name the site facts

What stays occupied below, the design load and who inspects daily

People who did not read the pack

Atria and shops stay open

What this document has to cover

This is not a temporary works propping RAMS. This job covers installing a crash deck or fan to catch falling materials over occupied space, and the control that keeps people safe is a written temporary-works design and a closed-area plan before the first beam is landed. If the RAMS never names what stays occupied below, the design load and who inspects daily, a principal contractor will send it back.

A crash-deck install rams only holds up if it names the site, the people at risk, the critical control, and the order of work. Principal contractors reject paragraphs that could apply to any job of this type.

Typical hazards to assess on this job

  • People hurt if a written temporary-works design and a closed-area plan before the first beam is landed is skipped on this crash-deck install job
  • Collapse of an underspecified deck
  • Fall while landing beams
  • Public still below an incomplete fan
  • Materials stored beyond the design load
  • The next crew inheriting an open crash-deck install hazard because handover was a text to nobody

Likelihood and severity change with occupancy, access, weather and other trades. Copying last month’s scores without looking at this site is how people get hurt.

A method sequence that actually protects people

Write the sequence so the critical control cannot be skipped. If isolation, edge protection or service location is the difference between safe and unsafe, it belongs before the work step — not in a general ‘PPE will be worn’ line.

  • Hold point: a written temporary-works design and a closed-area plan before the first beam is landed
  • Temporary-works coordinator accepts the design
  • Close the area below
  • Install to the drawing; no extra storage
  • Daily inspect
  • Permit occupancy below only when the design allows

Occupancy and other people

Atria and shops stay open. Write the closed floor and that a cleaner will walk under an incomplete fan as occupancy control, not a hope.

Substances and COSHH

An SDS is an input, not a COSHH assessment. If these substances appear on the job, attach assessments that describe quantity, duration, who is exposed and the controls you will actually use:

  • Paint on steel
  • Dust from drilling
  • Fixings

How SafeForJob helps

  • Describe this job in plain English and get suggested activities, risks and method steps
  • Edit every line before you download or issue
  • Reuse a previous RAMS and catch old client or site names
  • Attach or create COSHH assessments where hazardous substances appear

What this page is not

This page is not HSE approval, legal advice or a substitute for competent judgement. It helps you draft a clearer crash-deck install rams document for a named job. You remain responsible for reviewing and issuing it.

Related reading

See what a RAMS is, the free RAMS generator, and HSE guidance on managing risks.

Related pages

All rams by job · RAMS by trade · Free RAMS generator

Questions

Is this the same as a temporary works propping RAMS?
No. A crash-deck install RAMS has to name what stays occupied below, the design load and who inspects daily. A temporary works propping RAMS will not survive a competent review.
Can we skip a written temporary-works design and a closed-area plan before the first beam is landed?
No. A written temporary-works design and a closed-area plan before the first beam is landed is the hold point. Write it before the work step.
Who writes what stays occupied below, the design load and who inspects daily?
The competent person who issues this crash-deck install rams. A sticky note is not a handover.
Can AI issue this crash-deck install rams?
A tool can draft a crash-deck install pack. A competent person reviews and issues it for this site.