Lift engineer RAMS

Generic M&E RAMS miss the shaft. Landing control and lock-off have to be written.

Typical scope

  • Out of service
  • Lock-off
  • Landing barrier
  • Communication
  • Manufacturer procedure
  • Return test

Quick answer

A lift engineer RAMS is a site-specific pack for work in shafts, pits and machine spaces. Stored energy, falls and public landings are the point of the document.

Primary topic: lift engineer rams. UK contractors — review every document before you issue it. SafeForJob does not replace competent judgement or HSE guidance.

What usually goes wrong

These are the operational gaps that make generic Word RAMS fail on the next site.

  • Tape on a landing

    Not a control.

  • No lock-off

    Car moves.

  • Lone with no check-in

    No help.

Example

Breakdown in a shopping centre

Built from one job description. You review and adjust every item before issuing it.

Job description

Passenger lift 3 at Westgate Centre, Oxford. Out of service, landing barriers, lock-off, communication to a second person, return to service after test.

Activities identified

  • General site work
  • Electrical isolation

Method (7 steps)

  1. 1.Arrive and sign in. Arrive at Westgate Centre, Oxford, report to the Westgate FM site contact, sign in and complete any site induction.
  2. 2.Brief the team. Brief all operatives on this RAMS, the COSHH assessments and the emergency arrangements. Record attendance.
  3. 3.Isolate the electrical supply. Identify the relevant circuit, isolate, lock off and tag. Prove dead with an approved voltage indicator, proved before and after use.
  4. 4.Carry out electrical work. Carry out the electrical work on the isolated circuit to BS 7671.
  5. 5.Remove isolation and re-energise. Confirm the work is complete and everyone is clear, remove locks and re-energise.
  6. 6.Clear up and remove waste. Clear the work area, remove waste from site (including recovered refrigerant and hazardous waste) and leave the area safe.
  7. 7.Hand over and sign out. Hand over to the Westgate FM site contact, report anything outstanding and sign out.

Main risks (1 in total)

Electric shock or burns

Residual Medium

Who: Operatives, building occupants

  • Work carried out dead — no live working
  • Safe isolation: isolate, lock off, tag, and prove dead with an approved voltage indicator (GS38) proved before and after
  • Only competent, qualified electricians carry out electrical work
  • Permit to work obtained where the site requires one
  • Personal locks and keys retained by the person working

What to get right on this document

Car cannot move

Lock-off named.

Physical landing control

Person or barrier.

Communication

Works in a shaft.

What this document has to cover

Generic M&E RAMS miss the shaft. Landing control and lock-off have to be written.

A lift engineer rams only holds up if it names the site, the people at risk, the critical control, and the order of work. Principal contractors reject paragraphs that could apply to any job of this type.

Typical hazards to assess on this job

  • Fall into shaft
  • Crushing
  • Electric shock
  • Lone work
  • Pit restricted space
  • Public at landings

Likelihood and severity change with occupancy, access, weather and other trades. Copying last month’s scores without looking at this site is how people get hurt.

A method sequence that actually protects people

Write the sequence so the critical control cannot be skipped. If isolation, edge protection or service location is the difference between safe and unsafe, it belongs before the work step — not in a general ‘PPE will be worn’ line.

  • Take out of service
  • Isolate/lock off
  • Access car top or pit to procedure
  • Task
  • Test from safety
  • Return to service

Occupancy and other people

Lobbies stay public. Tape is not a landing door.

Substances and COSHH

An SDS is an input, not a COSHH assessment. If these substances appear on the job, attach assessments that describe quantity, duration, who is exposed and the controls you will actually use:

  • Oils
  • Hydraulic fluid
  • Cleaners

How SafeForJob helps

  • Describe this job in plain English and get suggested activities, risks and method steps
  • Edit every line before you download or issue
  • Reuse a previous RAMS and catch old client or site names
  • Attach or create COSHH assessments where hazardous substances appear

What this page is not

This page is not HSE approval, legal advice or a substitute for competent judgement. It helps you draft a clearer lift engineer rams document for a named job. You remain responsible for reviewing and issuing it.

Related reading

See what a RAMS is, the free RAMS generator, and HSE guidance on managing risks.

Related pages

All rams by trade · RAMS by trade · Free RAMS generator

Questions

Install vs service?
Install adds cranage and building interfaces — expand the RAMS.
MRL lifts?
Still isolation and crushing.
Firefighting lifts?
Client procedure may add steps — follow it.
Trapped passenger on arrival?
Rescue procedure first; maintenance RAMS starts after the car is safe.