Cladding installer RAMS

Improvised ‘equivalent’ panels and open bays overnight are what clients and building-control reject.

Typical scope

  • Specified system
  • Access inspected
  • Ground exclusion
  • Bay close-out
  • Waste route
  • Weather abort

Quick answer

A cladding installer RAMS is a site-specific pack for rainscreen or similar external wall systems. Height, falling materials and the specified system are the core.

Primary topic: cladding installation rams. UK contractors — review every document before you issue it. SafeForJob does not replace competent judgement or HSE guidance.

What usually goes wrong

These are the operational gaps that make generic Word RAMS fail on the next site.

  • Wrong system on site

    Not as specified.

  • Panels stored on balconies

    Load and fire.

  • No ground exclusion

    Public at risk.

Example

Rainscreen on a new frame

Built from one job description. You review and adjust every item before issuing it.

Job description

Install specified rainscreen on elevation C, Frame X, Leeds Dock. MEWP and scaffold mix, exclusion on the promenade, bays closed daily.

Activities identified

  • General site work
  • Working at height (MEWP)
  • Mobile tower or scaffold
  • Manual handling

Method (9 steps)

  1. 1.Arrive and sign in. Arrive at Leeds Dock, elevation C, report to the Dock Frame JV site contact, sign in and complete any site induction.
  2. 2.Brief the team. Brief all operatives on this RAMS, the COSHH assessments and the emergency arrangements. Record attendance.
  3. 3.Set up exclusion zone below. Establish an exclusion zone below the work area with barriers and signage before any work at height starts.
  4. 4.Set up the MEWP. Check ground conditions, position the MEWP, deploy outriggers on spreader plates and complete pre-use checks.
  5. 5.Erect the tower. PASMA-trained operatives erect the mobile tower to the manufacturer's guide and inspect it before use.
  6. 6.Disconnect and remove existing equipment. Disconnect and remove the existing equipment. Lower or carry it using mechanical aids or team lifts as planned.
  7. 7.Install new equipment. Position and fix the new equipment to the manufacturer's instructions.
  8. 8.Clear up and remove waste. Clear the work area, remove waste from site (including recovered refrigerant and hazardous waste) and leave the area safe.
  9. 9.Hand over and sign out. Hand over to the Dock Frame JV site contact, report anything outstanding and sign out.

Main risks (4 in total)

Fall from height (MEWP)

Residual Medium

Who: Operatives, people below

  • MEWP used instead of ladders for access to the work area
  • Operator holds a valid IPAF (or equivalent) licence for the machine category
  • Pre-use checks completed and recorded; thorough examination (LOLER) in date
  • Ground conditions checked; outriggers on spreader plates where required
  • Ground-level rescue plan in place and a trained person at ground level
  • Full-body harness with short work-restraint lanyard clipped to the basket anchor (boom MEWPs)

Falling objects

Residual Low

Who: People below, other trades, public

  • Exclusion zone set up below the work area with barriers and signage
  • Tools tethered when working at height; materials kept away from edges
  • Banksman or second person controls the area during lifts and removals
  • Hard hats worn in the exclusion zone

Fall from tower or scaffold, or collapse

Residual Medium

Who: Operatives, people nearby

  • Mobile towers erected by PASMA-trained persons to the manufacturer's guide
  • Scaffold erected by a competent scaffolder and tagged/inspected before use and every 7 days
  • Guard rails, toe boards and brick guards in place on working platforms
  • Castors locked and outriggers fitted; never moved while occupied

Manual handling

Residual Medium

Who: Operatives

  • Use mechanical aids (trolleys, sack trucks, hoists) for heavy items
  • Team lifts for items too heavy or awkward for one person
  • Route planned and cleared before moving items
  • Operatives trained in safe lifting techniques
  • Gloves with good grip and safety footwear

What to get right on this document

Specified only

No substitution.

Below is public

Exclusion.

Close the bay

Weather and fire.

What this document has to cover

Improvised ‘equivalent’ panels and open bays overnight are what clients and building-control reject.

A cladding installation rams only holds up if it names the site, the people at risk, the critical control, and the order of work. Principal contractors reject paragraphs that could apply to any job of this type.

Typical hazards to assess on this job

  • Falls
  • Falling panels
  • Fire of stored materials
  • Public below
  • Manual handling / lifting
  • Weather

Likelihood and severity change with occupancy, access, weather and other trades. Copying last month’s scores without looking at this site is how people get hurt.

A method sequence that actually protects people

Write the sequence so the critical control cannot be skipped. If isolation, edge protection or service location is the difference between safe and unsafe, it belongs before the work step — not in a general ‘PPE will be worn’ line.

  • Access handover
  • Exclusion below
  • Install to the specified system
  • Close bays weathertight
  • Waste off the elevation the same shift
  • Inspect

Occupancy and other people

Occupied buildings need resident routes and a sterile waste path.

Substances and COSHH

An SDS is an input, not a COSHH assessment. If these substances appear on the job, attach assessments that describe quantity, duration, who is exposed and the controls you will actually use:

  • Sealants
  • Insulation
  • Coatings

How SafeForJob helps

  • Describe this job in plain English and get suggested activities, risks and method steps
  • Edit every line before you download or issue
  • Reuse a previous RAMS and catch old client or site names
  • Attach or create COSHH assessments where hazardous substances appear

What this page is not

This page is not HSE approval, legal advice or a substitute for competent judgement. It helps you draft a clearer cladding installation rams document for a named job. You remain responsible for reviewing and issuing it.

Related reading

See what a RAMS is, the free RAMS generator, and HSE guidance on managing risks.

Related pages

All rams by trade · RAMS by trade · Free RAMS generator

Questions

Remediation vs new build?
Remediation adds residents and temporary fire strategy — use the remediation job page if that is the work.
ACM surveys?
Do not start strip without them.
Who inspects access?
Named in the RAMS.
Sealant COSHH?