Skip to content
SafeForJob

RAMS by job · UK

Tower scaffold use RAMS

Towers tip, are used incomplete, or are moved with people on them. The RAMS should make those failure modes impossible to skip.

Typical scope

  • Manufacturer sequence
  • Ground and wind limits
  • Tag/inspect
  • No moving occupied
  • Base exclusion
  • Competence (PASMA or equivalent)

Quick answer

A mobile tower RAMS covers erecting, using, moving and dismantling a tower. Stability, guardrails before use, and ground conditions are the controls — not ‘operatives are trained’ as the only line.

Primary topic: mobile tower scaffold rams. UK contractors — review every document before you issue it. SafeForJob does not replace competent judgement or HSE guidance.

What usually goes wrong

These are the operational gaps that make generic Word RAMS fail on the next site.

  • Erected incomplete

    No guardrails to ‘save time’.

  • Moved with a person on it

    Classic overturn.

  • Soft ground ignored

    Base plates missing.

Example

Atrium lighting from a tower

Built from one job description. You review and adjust every item before issuing it.

Job description

Erect a 6 m mobile tower in the atrium at County Hall, Aylesbury, to replace luminaires. PASMA erector, advanced guardrail, exclusion at base during public opening hours, never moved occupied.

Activities identified

  • General site work
  • Mobile tower or scaffold
  • Manual handling
  • Occupied premises or public areas

Method (8 steps)

  1. 1.Arrive and sign in. Arrive at County Hall, Aylesbury, report to the Buckinghamshire FM site contact, sign in and complete any site induction.
  2. 2.Brief the team. Brief all operatives on this RAMS, the COSHH assessments and the emergency arrangements. Record attendance.
  3. 3.Set up the work area. Set up barriers and signage around the work area and keep it clear of other people.
  4. 4.Erect the tower. PASMA-trained operatives erect the mobile tower to the manufacturer's guide and inspect it before use.
  5. 5.Disconnect and remove existing equipment. Disconnect and remove the existing equipment. Lower or carry it using mechanical aids or team lifts as planned.
  6. 6.Install new equipment. Position and fix the new equipment to the manufacturer's instructions.
  7. 7.Clear up and remove waste. Clear the work area, remove waste from site (including recovered refrigerant and hazardous waste) and leave the area safe.
  8. 8.Hand over and sign out. Hand over to the Buckinghamshire FM site contact, report anything outstanding and sign out.

Main risks (4 in total)

Fall from tower or scaffold, or collapse

Residual Medium

Who: Operatives, people nearby

  • Mobile towers erected by PASMA-trained persons to the manufacturer's guide
  • Scaffold erected by a competent scaffolder and tagged/inspected before use and every 7 days
  • Guard rails, toe boards and brick guards in place on working platforms
  • Castors locked and outriggers fitted; never moved while occupied

Falling objects

Residual Low

Who: People below, other trades, public

  • Exclusion zone set up below the work area with barriers and signage
  • Tools tethered when working at height; materials kept away from edges
  • Banksman or second person controls the area during lifts and removals
  • Hard hats worn in the exclusion zone

Manual handling

Residual Medium

Who: Operatives

  • Use mechanical aids (trolleys, sack trucks, hoists) for heavy items
  • Team lifts for items too heavy or awkward for one person
  • Route planned and cleared before moving items
  • Operatives trained in safe lifting techniques
  • Gloves with good grip and safety footwear

Members of the public and building occupants

Residual Low

Who: Public, customers, staff, residents

  • Work area segregated with barriers and clear signage
  • Work timed for quieter periods where possible, agreed with the site
  • Tools and materials never left unattended in public areas
  • Site contact informed of work areas and any disruption

What to get right on this document

Sequence is the control

Manufacturer’s method, not improvisation.

Inspect every shift

Tag visible.

Competence named

Who is allowed to erect.

What this document has to cover

Towers tip, are used incomplete, or are moved with people on them. The RAMS should make those failure modes impossible to skip.

A mobile tower scaffold rams only holds up if it names the site, the people at risk, the critical control, and the order of work. Principal contractors reject paragraphs that could apply to any job of this type.

Typical hazards to assess on this job

  • Collapse or overturn
  • Falls during erection
  • Moving a tower with people or materials on it
  • Overhead services and weak ground
  • Dropped tools
  • Public walking into the base

Likelihood and severity change with occupancy, access, weather and other trades. Copying last month’s scores without looking at this site is how people get hurt.

A method sequence that actually protects people

Write the sequence so the critical control cannot be skipped. If isolation, edge protection or service location is the difference between safe and unsafe, it belongs before the work step — not in a general ‘PPE will be worn’ line.

  • Check ground, wind and overheads; set out exclusion
  • Erect in the manufacturer’s sequence with guardrails as specified (through-the-trap or advanced guardrail)
  • Inspect and tag before first use each shift
  • Use with wheels locked; never move occupied
  • Dismantle in reverse sequence
  • Store components so they cannot fall or block escape

Occupancy and other people

Inside occupied atria and outside on pavements both need a base exclusion. A tower is not a room divider.

Substances and COSHH

An SDS is an input, not a COSHH assessment. If these substances appear on the job, attach assessments that describe quantity, duration, who is exposed and the controls you will actually use:

  • None typically unless cutting
  • Oil on wheels if maintained
  • Dust if used as a cutting platform — avoid that

How SafeForJob helps

  • Describe this job in plain English and get suggested activities, risks and method steps
  • Edit every line before you download or issue
  • Reuse a previous RAMS and catch old client or site names
  • Attach or create COSHH assessments where hazardous substances appear

What this page is not

This page is not HSE approval, legal advice or a substitute for competent judgement. It helps you draft a clearer mobile tower scaffold rams document for a named job. You remain responsible for reviewing and issuing it.

Related reading

See what a RAMS is, the free RAMS generator, and HSE guidance on managing risks.

Related pages

All rams by job · RAMS by trade · Free RAMS generator

Questions

Is PASMA legally required?
The law requires competence; PASMA is the usual way to show it for towers.
Indoor wind?
HVAC and atrium doors still matter; follow the manufacturer.
Can I use it on a slope?
Only with the manufacturer’s kit and a new assessment.
Tied towers?
If you tie, write the ties — it is no longer a simple mobile tower.