Skip to content
SafeForJob

RAMS by job · UK

Skylight / roof window install RAMS

The hole is the hazard. Methods that start with ‘fit window’ after the opening already exists are the ones clients bounce.

Typical scope

  • Immediate cover for the hole
  • Exclusion below
  • Glass handling plan
  • Weather abort
  • Services check
  • Same-shift weatherproofing

Quick answer

A skylight installation RAMS covers cutting an opening in a pitched or flat roof and fitting a window or lantern. Opening a hole in a roof is a fall-through risk until the unit is secured.

Primary topic: skylight installation rams. UK contractors — review every document before you issue it. SafeForJob does not replace competent judgement or HSE guidance.

What usually goes wrong

These are the operational gaps that make generic Word RAMS fail on the next site.

  • Opening left overnight

    Tarp ‘to be arranged’.

  • Room below occupied

    No exclusion.

  • Glass up a ladder

    No handling plan.

Example

Bedroom roof window

Built from one job description. You review and adjust every item before issuing it.

Job description

Fit a centre-pivot roof window in the rear pitch at 9 Alma Road, Sheffield. Independent scaffold, bedroom excluded, opening covered until the unit is weathered, two-person glass lift.

Activities identified

  • General site work
  • Roof work
  • Mobile tower or scaffold
  • Manual handling

Method (9 steps)

  1. 1.Arrive and sign in. Arrive at 9 Alma Road, Sheffield, report to the Private homeowner site contact, sign in and complete any site induction.
  2. 2.Brief the team. Brief all operatives on this RAMS, the COSHH assessments and the emergency arrangements. Record attendance.
  3. 3.Set up exclusion zone below. Establish an exclusion zone below the work area with barriers and signage before any work at height starts.
  4. 4.Erect the tower. PASMA-trained operatives erect the mobile tower to the manufacturer's guide and inspect it before use.
  5. 5.Access the roof. Access the roof via the agreed route. Confirm edge protection is in place and identify any fragile areas before moving onto the roof.
  6. 6.Disconnect and remove existing equipment. Disconnect and remove the existing equipment. Lower or carry it using mechanical aids or team lifts as planned.
  7. 7.Install new equipment. Position and fix the new equipment to the manufacturer's instructions.
  8. 8.Clear up and remove waste. Clear the work area, remove waste from site (including recovered refrigerant and hazardous waste) and leave the area safe.
  9. 9.Hand over and sign out. Hand over to the Private homeowner site contact, report anything outstanding and sign out.

Main risks (6 in total)

Fall from roof edge

Residual Medium

Who: Operatives

  • Plan work to be done from below or from a MEWP where possible
  • Edge protection (guard rails) or parapet of adequate height in place before work starts
  • Safe access route to the roof agreed with the site; roof hatch secured open
  • Where collective protection isn't possible, use a fall-restraint system with suitable anchors
  • Work stops in high winds, ice or heavy rain

Fall through fragile roof or rooflight

Residual Medium

Who: Operatives

  • Treat all roof sheets and rooflights as fragile unless confirmed otherwise by the site
  • Rooflights covered or protected with suitable mesh or barriers
  • Staging or crawling boards used; no walking directly on sheets
  • Safety netting or fall arrest below where required

Falling objects

Residual Low

Who: People below, other trades, public

  • Exclusion zone set up below the work area with barriers and signage
  • Tools tethered when working at height; materials kept away from edges
  • Banksman or second person controls the area during lifts and removals
  • Hard hats worn in the exclusion zone

Adverse weather

Residual Low

Who: Operatives

  • Forecast checked before work; work at height stopped in high winds
  • Breaks, water and shade in hot weather; warm clothing in cold
  • Sun protection on exposed work in summer

+ 2 more risks in the full RAMS.

What to get right on this document

Cover as a step

How the hole is made safe in minutes, not hours.

Glass is a load

Two-person or hoist, not a one-man lift up tiles.

Tell the people below

Even if it is the same household.

What this document has to cover

The hole is the hazard. Methods that start with ‘fit window’ after the opening already exists are the ones clients bounce.

A skylight installation rams only holds up if it names the site, the people at risk, the critical control, and the order of work. Principal contractors reject paragraphs that could apply to any job of this type.

Typical hazards to assess on this job

  • Fall through the new opening
  • Falls from eaves
  • Falling materials and glass
  • Weather entering the building
  • Manual handling of glass units
  • Services in the void (electrics, vents)

Likelihood and severity change with occupancy, access, weather and other trades. Copying last month’s scores without looking at this site is how people get hurt.

A method sequence that actually protects people

Write the sequence so the critical control cannot be skipped. If isolation, edge protection or service location is the difference between safe and unsafe, it belongs before the work step — not in a general ‘PPE will be worn’ line.

  • Protect the room below and agree weather limits
  • Edge protection and a plan for covering the opening immediately
  • Set out, check services, cut the opening
  • Install and weather the unit the same shift if possible
  • Internal linings, blinds and making good
  • Remove covers only when the unit is secure

Occupancy and other people

Bedrooms and classrooms below stay in use unless you exclude them. Dust and falling debris need more than a dust sheet left to chance.

Substances and COSHH

An SDS is an input, not a COSHH assessment. If these substances appear on the job, attach assessments that describe quantity, duration, who is exposed and the controls you will actually use:

  • Glass handling (cuts)
  • Sealants and foams
  • Timber dust

How SafeForJob helps

  • Describe this job in plain English and get suggested activities, risks and method steps
  • Edit every line before you download or issue
  • Reuse a previous RAMS and catch old client or site names
  • Attach or create COSHH assessments where hazardous substances appear

What this page is not

This page is not HSE approval, legal advice or a substitute for competent judgement. It helps you draft a clearer skylight installation rams document for a named job. You remain responsible for reviewing and issuing it.

Related reading

See what a RAMS is, the free RAMS generator, and HSE guidance on managing risks.

Related pages

All rams by job · RAMS by trade · Free RAMS generator

Questions

Flat roof lanterns?
Same hole-through risk plus often hot works for membranes — add them.
Do I need a structural check?
If you are cutting rafters, the RAMS should assume design is agreed, not improvised.
Internal finish another day?
External weatherproofing should not wait; linings can be phased.
What about existing Velux replacements?
Still a hole when the old unit is out — write the cover.