RAMS by job · UK
Rooftop antenna RAMS
You are on a roof with RF and a live edge, not pulling cable. A DAS RAMS that never mentions roof edge, a panel lift or a storm abort will fail the site-access controller.
Typical scope
- RF lock-off proved
- Roof access named
- Wind abort
- Tool lanyards
- Exclusion below
- Roof door not propped
Quick answer
A rooftop-antenna RAMS covers swapping or installing a donor or sector antenna on a named roof. Height, RF lock-off, lifting a panel and the public below are the critical harms.
Primary topic: rooftop antenna rams. UK contractors — review every document before you issue it. SafeForJob does not replace competent judgement or HSE guidance.
What usually goes wrong
These are the operational gaps that make generic Word RAMS fail on the next site.
DAS indoor RAMS reused
No roof, no sector lock.
Panel lifted in a 30 mph gust
Sail.
Roof door wedged with a battery
Access control.
Example
Sector swap on a hospital roof
Built from one job description. You review and adjust every item before issuing it.
Job description
Swap a sector antenna on the plant deck at Royal Infirmary, Coventry. RF lock-off with the MNO, edge protection, wind abort 25 mph, two-person panel lift, tool lanyards, west entrance exclusion, roof door locked behind the team.
Activities identified
- General site work
- Roof work
- Electrical isolation
- Manual handling
Method (11 steps)
- 1.Arrive and sign in. Arrive at Plant deck, Royal Infirmary, Coventry, report to the Trust Estates site contact, sign in and complete any site induction.
- 2.Brief the team. Brief all operatives on this RAMS, the COSHH assessments and the emergency arrangements. Record attendance.
- 3.Set up exclusion zone below. Establish an exclusion zone below the work area with barriers and signage before any work at height starts.
- 4.Isolate the electrical supply. Identify the relevant circuit, isolate, lock off and tag. Prove dead with an approved voltage indicator, proved before and after use.
- 5.Access the roof. Access the roof via the agreed route. Confirm edge protection is in place and identify any fragile areas before moving onto the roof.
- 6.Disconnect and remove existing equipment. Disconnect and remove the existing equipment. Lower or carry it using mechanical aids or team lifts as planned.
- 7.Install new equipment. Position and fix the new equipment to the manufacturer's instructions.
- 8.Carry out electrical work. Carry out the electrical work on the isolated circuit to BS 7671.
- 9.Remove isolation and re-energise. Confirm the work is complete and everyone is clear, remove locks and re-energise.
- 10.Clear up and remove waste. Clear the work area, remove waste from site (including recovered refrigerant and hazardous waste) and leave the area safe.
- 11.Hand over and sign out. Hand over to the Trust Estates site contact, report anything outstanding and sign out.
Main risks (6 in total)
Fall from roof edge
Residual MediumWho: Operatives
- Plan work to be done from below or from a MEWP where possible
- Edge protection (guard rails) or parapet of adequate height in place before work starts
- Safe access route to the roof agreed with the site; roof hatch secured open
- Where collective protection isn't possible, use a fall-restraint system with suitable anchors
- Work stops in high winds, ice or heavy rain
Fall through fragile roof or rooflight
Residual MediumWho: Operatives
- Treat all roof sheets and rooflights as fragile unless confirmed otherwise by the site
- Rooflights covered or protected with suitable mesh or barriers
- Staging or crawling boards used; no walking directly on sheets
- Safety netting or fall arrest below where required
Falling objects
Residual LowWho: People below, other trades, public
- Exclusion zone set up below the work area with barriers and signage
- Tools tethered when working at height; materials kept away from edges
- Banksman or second person controls the area during lifts and removals
- Hard hats worn in the exclusion zone
Adverse weather
Residual LowWho: Operatives
- Forecast checked before work; work at height stopped in high winds
- Breaks, water and shade in hot weather; warm clothing in cold
- Sun protection on exposed work in summer
+ 2 more risks in the full RAMS.
What to get right on this document
Lock off the sector
Prove it.
The roof is height
Access as for any roof job.
Wind is a stop
Panels sail.
What this document has to cover
You are on a roof with RF and a live edge, not pulling cable. A DAS RAMS that never mentions roof edge, a panel lift or a storm abort will fail the site-access controller.
A rooftop antenna rams only holds up if it names the site, the people at risk, the critical control, and the order of work. Principal contractors reject paragraphs that could apply to any job of this type.
Typical hazards to assess on this job
- Falls from the roof or through fragile lights
- RF burn or exposure if the sector is not locked off
- Dropped antenna onto the public or a plant deck
- Dropped tools from the steelwork
- Weather — wind on a sail-like panel
- Building users at a roof-access door you have propped
Likelihood and severity change with occupancy, access, weather and other trades. Copying last month’s scores without looking at this site is how people get hurt.
A method sequence that actually protects people
Write the sequence so the critical control cannot be skipped. If isolation, edge protection or service location is the difference between safe and unsafe, it belongs before the work step — not in a general ‘PPE will be worn’ line.
- Confirm site access, RF lock-off and a weather abort before you go up
- Set edge protection or a harness system as the roof requires; exclusion below
- Lock off the sector; prove it as the radio owner requires
- Lift and fix the antenna; lanyard tools
- Sweep only when the owner agrees; restore locks
- Close the roof door; do not leave a propped access
Occupancy and other people
High streets and hospital loops have people at the base. Write the spotter and that a propped roof door is a security and fall failure.
Substances and COSHH
An SDS is an input, not a COSHH assessment. If these substances appear on the job, attach assessments that describe quantity, duration, who is exposed and the controls you will actually use:
- Joint compounds on feeders
- Paint touch-up on steel
- Sealants at penetrations
How SafeForJob helps
- Describe this job in plain English and get suggested activities, risks and method steps
- Edit every line before you download or issue
- Reuse a previous RAMS and catch old client or site names
- Attach or create COSHH assessments where hazardous substances appear
What this page is not
This page is not HSE approval, legal advice or a substitute for competent judgement. It helps you draft a clearer rooftop antenna rams document for a named job. You remain responsible for reviewing and issuing it.
Related reading
See what a RAMS is, the free RAMS generator, and HSE guidance on managing risks.
Related pages
- RAMS by tradeTelecoms RAMSCreate data cabling rams online for UK sites. Suggested risks and method steps matched to the job — you review every item before issue.
- GuidesWhat is a RAMS?RAMS means risk assessment and method statement — usually one site-specific pack for a construction or maintenance job. Practical UK guidance for contractors — with links to free tools.
- Method statementsRoofing method statementWrite a roofing method statement for a named UK site. Clear sequence, interfaces and controls — review before issue.
- RAMS by jobConsumer unit replacement RAMSCreate a consumer unit replacement rams for a named UK site. Suggested risks and method steps you review before download or issue.
- RAMS by jobEV charger installation RAMSCreate a ev charger installation rams for a named UK site. Suggested risks and method steps you review before download or issue.
- RAMS by jobLighting rewire RAMSCreate a lighting rewire rams for a named UK site. Suggested risks and method steps you review before download or issue.
- RAMS by jobEICR testing RAMSCreate a eicr method statement for a named UK site. Suggested risks and method steps you review before download or issue.
- RAMS by jobRooftop condenser replacement RAMSCreate a rooftop ac unit replacement rams for a named UK site. Suggested risks and method steps you review before download or issue.
- RAMS by jobSplit system installation RAMSCreate a split system installation rams for a named UK site. Suggested risks and method steps you review before download or issue.
Questions
- Is this lightning protection?
- Related roof steel, different RF lock-off. Use this for antennas.
- Do I need IRATA?
- Only if the access is rope — then attach that RAMS.
- Who proves RF lock-off?
- The radio owner’s process — name them.
- Can I work in rain?
- Abort if the roof is a slip and the panel is a sail — write the limit.