Skip to content
SafeForJob

RAMS by job · UK

Rooftop antenna RAMS

You are on a roof with RF and a live edge, not pulling cable. A DAS RAMS that never mentions roof edge, a panel lift or a storm abort will fail the site-access controller.

Typical scope

  • RF lock-off proved
  • Roof access named
  • Wind abort
  • Tool lanyards
  • Exclusion below
  • Roof door not propped

Quick answer

A rooftop-antenna RAMS covers swapping or installing a donor or sector antenna on a named roof. Height, RF lock-off, lifting a panel and the public below are the critical harms.

Primary topic: rooftop antenna rams. UK contractors — review every document before you issue it. SafeForJob does not replace competent judgement or HSE guidance.

What usually goes wrong

These are the operational gaps that make generic Word RAMS fail on the next site.

  • DAS indoor RAMS reused

    No roof, no sector lock.

  • Panel lifted in a 30 mph gust

    Sail.

  • Roof door wedged with a battery

    Access control.

Example

Sector swap on a hospital roof

Built from one job description. You review and adjust every item before issuing it.

Job description

Swap a sector antenna on the plant deck at Royal Infirmary, Coventry. RF lock-off with the MNO, edge protection, wind abort 25 mph, two-person panel lift, tool lanyards, west entrance exclusion, roof door locked behind the team.

Activities identified

  • General site work
  • Roof work
  • Electrical isolation
  • Manual handling

Method (11 steps)

  1. 1.Arrive and sign in. Arrive at Plant deck, Royal Infirmary, Coventry, report to the Trust Estates site contact, sign in and complete any site induction.
  2. 2.Brief the team. Brief all operatives on this RAMS, the COSHH assessments and the emergency arrangements. Record attendance.
  3. 3.Set up exclusion zone below. Establish an exclusion zone below the work area with barriers and signage before any work at height starts.
  4. 4.Isolate the electrical supply. Identify the relevant circuit, isolate, lock off and tag. Prove dead with an approved voltage indicator, proved before and after use.
  5. 5.Access the roof. Access the roof via the agreed route. Confirm edge protection is in place and identify any fragile areas before moving onto the roof.
  6. 6.Disconnect and remove existing equipment. Disconnect and remove the existing equipment. Lower or carry it using mechanical aids or team lifts as planned.
  7. 7.Install new equipment. Position and fix the new equipment to the manufacturer's instructions.
  8. 8.Carry out electrical work. Carry out the electrical work on the isolated circuit to BS 7671.
  9. 9.Remove isolation and re-energise. Confirm the work is complete and everyone is clear, remove locks and re-energise.
  10. 10.Clear up and remove waste. Clear the work area, remove waste from site (including recovered refrigerant and hazardous waste) and leave the area safe.
  11. 11.Hand over and sign out. Hand over to the Trust Estates site contact, report anything outstanding and sign out.

Main risks (6 in total)

Fall from roof edge

Residual Medium

Who: Operatives

  • Plan work to be done from below or from a MEWP where possible
  • Edge protection (guard rails) or parapet of adequate height in place before work starts
  • Safe access route to the roof agreed with the site; roof hatch secured open
  • Where collective protection isn't possible, use a fall-restraint system with suitable anchors
  • Work stops in high winds, ice or heavy rain

Fall through fragile roof or rooflight

Residual Medium

Who: Operatives

  • Treat all roof sheets and rooflights as fragile unless confirmed otherwise by the site
  • Rooflights covered or protected with suitable mesh or barriers
  • Staging or crawling boards used; no walking directly on sheets
  • Safety netting or fall arrest below where required

Falling objects

Residual Low

Who: People below, other trades, public

  • Exclusion zone set up below the work area with barriers and signage
  • Tools tethered when working at height; materials kept away from edges
  • Banksman or second person controls the area during lifts and removals
  • Hard hats worn in the exclusion zone

Adverse weather

Residual Low

Who: Operatives

  • Forecast checked before work; work at height stopped in high winds
  • Breaks, water and shade in hot weather; warm clothing in cold
  • Sun protection on exposed work in summer

+ 2 more risks in the full RAMS.

What to get right on this document

Lock off the sector

Prove it.

The roof is height

Access as for any roof job.

Wind is a stop

Panels sail.

What this document has to cover

You are on a roof with RF and a live edge, not pulling cable. A DAS RAMS that never mentions roof edge, a panel lift or a storm abort will fail the site-access controller.

A rooftop antenna rams only holds up if it names the site, the people at risk, the critical control, and the order of work. Principal contractors reject paragraphs that could apply to any job of this type.

Typical hazards to assess on this job

  • Falls from the roof or through fragile lights
  • RF burn or exposure if the sector is not locked off
  • Dropped antenna onto the public or a plant deck
  • Dropped tools from the steelwork
  • Weather — wind on a sail-like panel
  • Building users at a roof-access door you have propped

Likelihood and severity change with occupancy, access, weather and other trades. Copying last month’s scores without looking at this site is how people get hurt.

A method sequence that actually protects people

Write the sequence so the critical control cannot be skipped. If isolation, edge protection or service location is the difference between safe and unsafe, it belongs before the work step — not in a general ‘PPE will be worn’ line.

  • Confirm site access, RF lock-off and a weather abort before you go up
  • Set edge protection or a harness system as the roof requires; exclusion below
  • Lock off the sector; prove it as the radio owner requires
  • Lift and fix the antenna; lanyard tools
  • Sweep only when the owner agrees; restore locks
  • Close the roof door; do not leave a propped access

Occupancy and other people

High streets and hospital loops have people at the base. Write the spotter and that a propped roof door is a security and fall failure.

Substances and COSHH

An SDS is an input, not a COSHH assessment. If these substances appear on the job, attach assessments that describe quantity, duration, who is exposed and the controls you will actually use:

  • Joint compounds on feeders
  • Paint touch-up on steel
  • Sealants at penetrations

How SafeForJob helps

  • Describe this job in plain English and get suggested activities, risks and method steps
  • Edit every line before you download or issue
  • Reuse a previous RAMS and catch old client or site names
  • Attach or create COSHH assessments where hazardous substances appear

What this page is not

This page is not HSE approval, legal advice or a substitute for competent judgement. It helps you draft a clearer rooftop antenna rams document for a named job. You remain responsible for reviewing and issuing it.

Related reading

See what a RAMS is, the free RAMS generator, and HSE guidance on managing risks.

Related pages

All rams by job · RAMS by trade · Free RAMS generator

Questions

Is this lightning protection?
Related roof steel, different RF lock-off. Use this for antennas.
Do I need IRATA?
Only if the access is rope — then attach that RAMS.
Who proves RF lock-off?
The radio owner’s process — name them.
Can I work in rain?
Abort if the roof is a slip and the panel is a sail — write the limit.