RAMS by job · UK
Roller shutter installation RAMS
A shutter is a moving load over a doorway people still use. A generic fire-door RAMS that never mentions the barrel lift, springs or a banksman on the pavement will not do.
Typical scope
- Barrel lift plan
- Exclusion under the opening
- Electrical isolation
- Safety edge before auto-run
- Fire strategy if a fire shutter
- Public marshalling
Quick answer
A roller shutter RAMS covers fitting or replacing powered or manual shutters on a named opening. Lifting the barrel, electrical isolation, crushing on the curtain, and the public at a shopfront are the core.
Primary topic: roller shutter rams. UK contractors — review every document before you issue it. SafeForJob does not replace competent judgement or HSE guidance.
What usually goes wrong
These are the operational gaps that make generic Word RAMS fail on the next site.
Door RAMS reused
No barrel lift.
Auto-run to test with shoppers under
No exclusion.
Fire shutter left open overnight
Strategy broken.
Example
Shopfront shutter on a trading high street
Built from one job description. You review and adjust every item before issuing it.
Job description
Replace the motorised roller shutter at 22 High Street, Chester, Sunday 07:00–12:00. Pavement exclusion, two-person barrel lift from a scissor, isolate the motor, safety edge before any auto-run, shop closed until tested.
Activities identified
- General site work
- Manual handling
- Occupied premises or public areas
Method (7 steps)
- 1.Arrive and sign in. Arrive at 22 High Street, Chester, report to the High Street Retail Ltd site contact, sign in and complete any site induction.
- 2.Brief the team. Brief all operatives on this RAMS, the COSHH assessments and the emergency arrangements. Record attendance.
- 3.Set up the work area. Set up barriers and signage around the work area and keep it clear of other people.
- 4.Disconnect and remove existing equipment. Disconnect and remove the existing equipment. Lower or carry it using mechanical aids or team lifts as planned.
- 5.Install new equipment. Position and fix the new equipment to the manufacturer's instructions.
- 6.Clear up and remove waste. Clear the work area, remove waste from site (including recovered refrigerant and hazardous waste) and leave the area safe.
- 7.Hand over and sign out. Hand over to the High Street Retail Ltd site contact, report anything outstanding and sign out.
Main risks (2 in total)
Manual handling
Residual MediumWho: Operatives
- Use mechanical aids (trolleys, sack trucks, hoists) for heavy items
- Team lifts for items too heavy or awkward for one person
- Route planned and cleared before moving items
- Operatives trained in safe lifting techniques
- Gloves with good grip and safety footwear
Members of the public and building occupants
Residual LowWho: Public, customers, staff, residents
- Work area segregated with barriers and clear signage
- Work timed for quieter periods where possible, agreed with the site
- Tools and materials never left unattended in public areas
- Site contact informed of work areas and any disruption
What to get right on this document
The barrel is a lift
Plan and exclusion.
Edges before auto
Same idea as powered gates.
Fire shutters follow the strategy
Do not leave them open as a convenience.
What this document has to cover
A shutter is a moving load over a doorway people still use. A generic fire-door RAMS that never mentions the barrel lift, springs or a banksman on the pavement will not do.
A roller shutter rams only holds up if it names the site, the people at risk, the critical control, and the order of work. Principal contractors reject paragraphs that could apply to any job of this type.
Typical hazards to assess on this job
- Dropped barrel or curtain during the lift
- Crushing in the guides or under a descending curtain
- Electric shock on motors and controls
- Work at height over the opening
- Public walking under a curtain that is not yet secured
- Fire-resisting shutters left open overnight against the fire strategy
Likelihood and severity change with occupancy, access, weather and other trades. Copying last month’s scores without looking at this site is how people get hurt.
A method sequence that actually protects people
Write the sequence so the critical control cannot be skipped. If isolation, edge protection or service location is the difference between safe and unsafe, it belongs before the work step — not in a general ‘PPE will be worn’ line.
- Agree whether the opening stays in use and set a hard exclusion under the barrel
- Isolate electrical supplies; support the existing curtain before unbolting
- Lift and fix the new barrel with a planned lift — not a human chain on a ladder
- Fit guides, motor, safety edge; test the run from a position of safety
- For fire shutters, confirm the fire strategy and interlock before leaving
- Hand over isolation, override and the remaining defects
Occupancy and other people
Shopfronts and loading bays stay busy. People will duck under a half-fitted curtain. Write marshalling and that the opening is either fully controlled or fully closed.
Substances and COSHH
An SDS is an input, not a COSHH assessment. If these substances appear on the job, attach assessments that describe quantity, duration, who is exposed and the controls you will actually use:
- Grease
- Solvents for cleaning guides
- Paints on making-good
How SafeForJob helps
- Describe this job in plain English and get suggested activities, risks and method steps
- Edit every line before you download or issue
- Reuse a previous RAMS and catch old client or site names
- Attach or create COSHH assessments where hazardous substances appear
What this page is not
This page is not HSE approval, legal advice or a substitute for competent judgement. It helps you draft a clearer roller shutter rams document for a named job. You remain responsible for reviewing and issuing it.
Related reading
See what a RAMS is, the free RAMS generator, and HSE guidance on managing risks.
Related pages
- RAMS by tradeFire & security RAMSCreate RAMS for fire alarm, CCTV and access control installation: system isolations, ceiling work, occupied buildings. Review every suggestion before issue.
- GuidesWhat is a RAMS?RAMS means risk assessment and method statement — usually one site-specific pack for a construction or maintenance job. Practical UK guidance for contractors — with links to free tools.
- Method statementsFit-out method statementWrite a fit out method statement for a named UK site. Clear sequence, interfaces and controls — review before issue.
- RAMS by jobConsumer unit replacement RAMSCreate a consumer unit replacement rams for a named UK site. Suggested risks and method steps you review before download or issue.
- RAMS by jobEV charger installation RAMSCreate a ev charger installation rams for a named UK site. Suggested risks and method steps you review before download or issue.
- RAMS by jobLighting rewire RAMSCreate a lighting rewire rams for a named UK site. Suggested risks and method steps you review before download or issue.
- RAMS by jobEICR testing RAMSCreate a eicr method statement for a named UK site. Suggested risks and method steps you review before download or issue.
- RAMS by jobRooftop condenser replacement RAMSCreate a rooftop ac unit replacement rams for a named UK site. Suggested risks and method steps you review before download or issue.
- RAMS by jobSplit system installation RAMSCreate a split system installation rams for a named UK site. Suggested risks and method steps you review before download or issue.
Questions
- Is a fire shutter different?
- Yes — drop-test, fusible links or signal from the alarm, and the fire strategy. Write them.
- Manual vs powered?
- Drop motor/isolation steps for manual; crushing and the lift remain.
- Loading-bay lorry dock?
- Add vehicle interface and a banksman.
- Can I use a MEWP in the door?
- Only if ground and exclusion work — name the machine.