RAMS by job · UK
Raised access flooring RAMS
The void is a service space and a trip factory. A fit-out RAMS that never mentions open-tile discipline, fire barriers in the void or how you stop a chair leg disappearing will fail the IT and fire officer.
Typical scope
- Open-tile guards
- Void survey
- Fire barriers same visit
- Tiles stored off escape
- Cutting bay
- Load notice at handover
Quick answer
A raised-access-floor RAMS covers installing or opening a pedestal floor in a named office or hall. Void services, falling into an open tile, and not blocking an escape with stacks of tiles are the usual harms.
Primary topic: raised access floor rams. UK contractors — review every document before you issue it. SafeForJob does not replace competent judgement or HSE guidance.
What usually goes wrong
These are the operational gaps that make generic Word RAMS fail on the next site.
Carpet RAMS reused
No void, no pedestals.
A run left open overnight
A fall.
Barriers ‘later’
Fire strategy.
Example
New RAF in a live comms annex
Built from one job description. You review and adjust every item before issuing it.
Job description
Install raised floor in annex B at Nexus Data, Stockport. Weekend, void surveyed, fire barriers as drawn, open tiles guarded, cutting in the loading bay, tiles on pallets off the escape, load notice before Monday chairs.
Activities identified
- General site work
- Manual handling
- Power tools
- Plant and vehicle movement
- Lone working
Method (7 steps)
- 1.Arrive and sign in. Arrive at Annex B, Nexus Data, Stockport, report to the Nexus Data Ltd site contact, sign in and complete any site induction.
- 2.Brief the team. Brief all operatives on this RAMS, the COSHH assessments and the emergency arrangements. Record attendance.
- 3.Disconnect and remove existing equipment. Disconnect and remove the existing equipment. Lower or carry it using mechanical aids or team lifts as planned.
- 4.Drill and fix. Mark out, then drill and fix using on-tool dust extraction. Check for hidden cables and pipes before drilling.
- 5.Install new equipment. Position and fix the new equipment to the manufacturer's instructions.
- 6.Clear up and remove waste. Clear the work area, remove waste from site (including recovered refrigerant and hazardous waste) and leave the area safe.
- 7.Hand over and sign out. Hand over to the Nexus Data Ltd site contact, report anything outstanding and sign out.
Main risks (5 in total)
Manual handling
Residual MediumWho: Operatives
- Use mechanical aids (trolleys, sack trucks, hoists) for heavy items
- Team lifts for items too heavy or awkward for one person
- Route planned and cleared before moving items
- Operatives trained in safe lifting techniques
- Gloves with good grip and safety footwear
Hand and power tools
Residual LowWho: Operatives
- Battery or 110V tools used; no 230V tools on site without RCD protection
- Tools inspected before use and PAT tested where applicable
- Guards fitted and used as designed
- Eye protection and gloves suitable for the task
Noise and hand-arm vibration
Residual MediumWho: Operatives, people nearby
- Low-vibration, low-noise tools selected
- Trigger times limited and rotated between operatives
- Noisy work scheduled to reduce disruption to occupants
- Hearing protection worn where noise is high
Moving vehicles and plant
Residual MediumWho: Operatives, public, site staff
- Pedestrians segregated from vehicle and plant routes
- Plant operated by trained, authorised operators only
- Banksman used for reversing and manoeuvring
- High-visibility clothing worn
+ 1 more risks in the full RAMS.
What to get right on this document
Guard every hole
Including lunch.
Barriers as you go
Not a snag.
The escape is not a store
Tiles elsewhere.
What this document has to cover
The void is a service space and a trip factory. A fit-out RAMS that never mentions open-tile discipline, fire barriers in the void or how you stop a chair leg disappearing will fail the IT and fire officer.
A raised access floor rams only holds up if it names the site, the people at risk, the critical control, and the order of work. Principal contractors reject paragraphs that could apply to any job of this type.
Typical hazards to assess on this job
- Falls into an open tile or a run of missing floor
- Services in the void — electric, fibre, water — damaged or live
- Manual handling of stone or wood-core tiles
- Fire barriers in the void left open
- Stacks of tiles blocking an escape
- Dust from cutting tiles in a live office
Likelihood and severity change with occupancy, access, weather and other trades. Copying last month’s scores without looking at this site is how people get hurt.
A method sequence that actually protects people
Write the sequence so the critical control cannot be skipped. If isolation, edge protection or service location is the difference between safe and unsafe, it belongs before the work step — not in a general ‘PPE will be worn’ line.
- Survey the void and fire barriers before a run is opened
- Open only what you can guard; never leave a hole unmarked
- Install pedestals and tiles to the specified grid and load
- Reinstated fire barriers the same visit you disturb them
- Cut in a bay with dust control; store tiles off the escape
- Hand over load notices and remaining open panels
Occupancy and other people
Offices walk the floor you are opening. Write the local exclusion and that a night cleaner will not see an unmarked void.
Substances and COSHH
An SDS is an input, not a COSHH assessment. If these substances appear on the job, attach assessments that describe quantity, duration, who is exposed and the controls you will actually use:
- Tile dust / adhesives if bonding
- Void dust (characterise in older buildings)
- Fire-stopping if you make good barriers
How SafeForJob helps
- Describe this job in plain English and get suggested activities, risks and method steps
- Edit every line before you download or issue
- Reuse a previous RAMS and catch old client or site names
- Attach or create COSHH assessments where hazardous substances appear
What this page is not
This page is not HSE approval, legal advice or a substitute for competent judgement. It helps you draft a clearer raised access floor rams document for a named job. You remain responsible for reviewing and issuing it.
Related reading
See what a RAMS is, the free RAMS generator, and HSE guidance on managing risks.
Related pages
- RAMS by tradeFlooring RAMSCreate floor preparation method statement online for UK sites. Suggested risks and method steps matched to the job — you review every item before issue.
- GuidesWhat is a RAMS?RAMS means risk assessment and method statement — usually one site-specific pack for a construction or maintenance job. Practical UK guidance for contractors — with links to free tools.
- Method statementsFit-out method statementWrite a fit out method statement for a named UK site. Clear sequence, interfaces and controls — review before issue.
- RAMS by jobConsumer unit replacement RAMSCreate a consumer unit replacement rams for a named UK site. Suggested risks and method steps you review before download or issue.
- RAMS by jobEV charger installation RAMSCreate a ev charger installation rams for a named UK site. Suggested risks and method steps you review before download or issue.
- RAMS by jobLighting rewire RAMSCreate a lighting rewire rams for a named UK site. Suggested risks and method steps you review before download or issue.
- RAMS by jobEICR testing RAMSCreate a eicr method statement for a named UK site. Suggested risks and method steps you review before download or issue.
- RAMS by jobRooftop condenser replacement RAMSCreate a rooftop ac unit replacement rams for a named UK site. Suggested risks and method steps you review before download or issue.
- RAMS by jobSplit system installation RAMSCreate a split system installation rams for a named UK site. Suggested risks and method steps you review before download or issue.
Questions
- Is this a mezzanine?
- No — pedestals on a slab, not a steel deck.
- Can I use the void as a dump?
- No. Waste out the same visit.
- Who owns void services?
- Name IT and M&E before you cut a tile.
- Asbestos in old void dust?
- Survey in older buildings before a blow-down.