Skip to content
SafeForJob

RAMS by job · UK

Raised access flooring RAMS

The void is a service space and a trip factory. A fit-out RAMS that never mentions open-tile discipline, fire barriers in the void or how you stop a chair leg disappearing will fail the IT and fire officer.

Typical scope

  • Open-tile guards
  • Void survey
  • Fire barriers same visit
  • Tiles stored off escape
  • Cutting bay
  • Load notice at handover

Quick answer

A raised-access-floor RAMS covers installing or opening a pedestal floor in a named office or hall. Void services, falling into an open tile, and not blocking an escape with stacks of tiles are the usual harms.

Primary topic: raised access floor rams. UK contractors — review every document before you issue it. SafeForJob does not replace competent judgement or HSE guidance.

What usually goes wrong

These are the operational gaps that make generic Word RAMS fail on the next site.

  • Carpet RAMS reused

    No void, no pedestals.

  • A run left open overnight

    A fall.

  • Barriers ‘later’

    Fire strategy.

Example

New RAF in a live comms annex

Built from one job description. You review and adjust every item before issuing it.

Job description

Install raised floor in annex B at Nexus Data, Stockport. Weekend, void surveyed, fire barriers as drawn, open tiles guarded, cutting in the loading bay, tiles on pallets off the escape, load notice before Monday chairs.

Activities identified

  • General site work
  • Manual handling
  • Power tools
  • Plant and vehicle movement
  • Lone working

Method (7 steps)

  1. 1.Arrive and sign in. Arrive at Annex B, Nexus Data, Stockport, report to the Nexus Data Ltd site contact, sign in and complete any site induction.
  2. 2.Brief the team. Brief all operatives on this RAMS, the COSHH assessments and the emergency arrangements. Record attendance.
  3. 3.Disconnect and remove existing equipment. Disconnect and remove the existing equipment. Lower or carry it using mechanical aids or team lifts as planned.
  4. 4.Drill and fix. Mark out, then drill and fix using on-tool dust extraction. Check for hidden cables and pipes before drilling.
  5. 5.Install new equipment. Position and fix the new equipment to the manufacturer's instructions.
  6. 6.Clear up and remove waste. Clear the work area, remove waste from site (including recovered refrigerant and hazardous waste) and leave the area safe.
  7. 7.Hand over and sign out. Hand over to the Nexus Data Ltd site contact, report anything outstanding and sign out.

Main risks (5 in total)

Manual handling

Residual Medium

Who: Operatives

  • Use mechanical aids (trolleys, sack trucks, hoists) for heavy items
  • Team lifts for items too heavy or awkward for one person
  • Route planned and cleared before moving items
  • Operatives trained in safe lifting techniques
  • Gloves with good grip and safety footwear

Hand and power tools

Residual Low

Who: Operatives

  • Battery or 110V tools used; no 230V tools on site without RCD protection
  • Tools inspected before use and PAT tested where applicable
  • Guards fitted and used as designed
  • Eye protection and gloves suitable for the task

Noise and hand-arm vibration

Residual Medium

Who: Operatives, people nearby

  • Low-vibration, low-noise tools selected
  • Trigger times limited and rotated between operatives
  • Noisy work scheduled to reduce disruption to occupants
  • Hearing protection worn where noise is high

Moving vehicles and plant

Residual Medium

Who: Operatives, public, site staff

  • Pedestrians segregated from vehicle and plant routes
  • Plant operated by trained, authorised operators only
  • Banksman used for reversing and manoeuvring
  • High-visibility clothing worn

+ 1 more risks in the full RAMS.

What to get right on this document

Guard every hole

Including lunch.

Barriers as you go

Not a snag.

The escape is not a store

Tiles elsewhere.

What this document has to cover

The void is a service space and a trip factory. A fit-out RAMS that never mentions open-tile discipline, fire barriers in the void or how you stop a chair leg disappearing will fail the IT and fire officer.

A raised access floor rams only holds up if it names the site, the people at risk, the critical control, and the order of work. Principal contractors reject paragraphs that could apply to any job of this type.

Typical hazards to assess on this job

  • Falls into an open tile or a run of missing floor
  • Services in the void — electric, fibre, water — damaged or live
  • Manual handling of stone or wood-core tiles
  • Fire barriers in the void left open
  • Stacks of tiles blocking an escape
  • Dust from cutting tiles in a live office

Likelihood and severity change with occupancy, access, weather and other trades. Copying last month’s scores without looking at this site is how people get hurt.

A method sequence that actually protects people

Write the sequence so the critical control cannot be skipped. If isolation, edge protection or service location is the difference between safe and unsafe, it belongs before the work step — not in a general ‘PPE will be worn’ line.

  • Survey the void and fire barriers before a run is opened
  • Open only what you can guard; never leave a hole unmarked
  • Install pedestals and tiles to the specified grid and load
  • Reinstated fire barriers the same visit you disturb them
  • Cut in a bay with dust control; store tiles off the escape
  • Hand over load notices and remaining open panels

Occupancy and other people

Offices walk the floor you are opening. Write the local exclusion and that a night cleaner will not see an unmarked void.

Substances and COSHH

An SDS is an input, not a COSHH assessment. If these substances appear on the job, attach assessments that describe quantity, duration, who is exposed and the controls you will actually use:

  • Tile dust / adhesives if bonding
  • Void dust (characterise in older buildings)
  • Fire-stopping if you make good barriers

How SafeForJob helps

  • Describe this job in plain English and get suggested activities, risks and method steps
  • Edit every line before you download or issue
  • Reuse a previous RAMS and catch old client or site names
  • Attach or create COSHH assessments where hazardous substances appear

What this page is not

This page is not HSE approval, legal advice or a substitute for competent judgement. It helps you draft a clearer raised access floor rams document for a named job. You remain responsible for reviewing and issuing it.

Related reading

See what a RAMS is, the free RAMS generator, and HSE guidance on managing risks.

Related pages

All rams by job · RAMS by trade · Free RAMS generator

Questions

Is this a mezzanine?
No — pedestals on a slab, not a steel deck.
Can I use the void as a dump?
No. Waste out the same visit.
Who owns void services?
Name IT and M&E before you cut a tile.
Asbestos in old void dust?
Survey in older buildings before a blow-down.