Skip to content
SafeForJob

RAMS by job · UK

Manhole construction RAMS

A manhole is a confined-space-adjacent structure on a live drain, not a soakaway pit. A sewer-connection RAMS that never mentions rings, a concrete bench or how you stop someone entering an unguarded shaft will fail.

Typical scope

  • Shoring
  • Flow control
  • Opening guarded always
  • No unplanned entry
  • Cover locked when unattended
  • Highway reinstatement

Quick answer

A manhole-construction RAMS covers building a new chamber on a named drainage run. Excavation, wet concrete, confined access and live flows are the critical harms.

Primary topic: manhole construction rams. UK contractors — review every document before you issue it. SafeForJob does not replace competent judgement or HSE guidance.

What usually goes wrong

These are the operational gaps that make generic Word RAMS fail on the next site.

  • Soakaway RAMS reused

    No chamber, no fall.

  • Someone in the ring to trowel

    No entry plan.

  • Cover left off overnight

    A hole in a drive.

Example

New manhole on a housing lateral

Built from one job description. You review and adjust every item before issuing it.

Job description

Build a new manhole on Plot 6, Willow Beck, York. Shoring, overpump the live run, rings as drawn, no man-entry, opening plated whenever unattended, cover locked Friday, drive reinstated.

Activities identified

  • General site work
  • Confined space

Method (5 steps)

  1. 1.Arrive and sign in. Arrive at Plot 6, Willow Beck, York, report to the Willow Beck Developments site contact, sign in and complete any site induction.
  2. 2.Brief the team. Brief all operatives on this RAMS, the COSHH assessments and the emergency arrangements. Record attendance.
  3. 3.Confined space permit and gas test. Obtain the permit to work, test the atmosphere and confirm rescue arrangements before anyone enters.
  4. 4.Clear up and remove waste. Clear the work area, remove waste from site (including recovered refrigerant and hazardous waste) and leave the area safe.
  5. 5.Hand over and sign out. Hand over to the Willow Beck Developments site contact, report anything outstanding and sign out.

Main risks (1 in total)

Confined space

Residual Medium

Who: Operatives, rescuers

  • Avoid entry — do the work from outside where possible
  • Permit to work and confined space trained operatives
  • Atmosphere tested before and during entry with a calibrated gas monitor
  • Emergency rescue arrangements in place before entry

What to get right on this document

Guard the hole always

Even for a minute.

Entry is a different method

Plan it or stay out.

Flow is designed

Overpump or plug.

What this document has to cover

A manhole is a confined-space-adjacent structure on a live drain, not a soakaway pit. A sewer-connection RAMS that never mentions rings, a concrete bench or how you stop someone entering an unguarded shaft will fail.

A manhole construction rams only holds up if it names the site, the people at risk, the critical control, and the order of work. Principal contractors reject paragraphs that could apply to any job of this type.

Typical hazards to assess on this job

  • Excavation collapse around the shaft
  • Falls into an unguarded chamber
  • Contact with sewage if you break into a live run
  • Wet-concrete burns on the bench
  • Gases if anyone enters
  • Public at a chamber in a road or garden

Likelihood and severity change with occupancy, access, weather and other trades. Copying last month’s scores without looking at this site is how people get hurt.

A method sequence that actually protects people

Write the sequence so the critical control cannot be skipped. If isolation, edge protection or service location is the difference between safe and unsafe, it belongs before the work step — not in a general ‘PPE will be worn’ line.

  • Permits, flow control and shoring before the excavation opens
  • Build rings or the specified chamber; guard the opening whenever you look away
  • Bench and pipe as designed; hygiene if live sewage is present
  • Do not enter to finish the bench unless a confined-space plan is in force
  • Backfill in layers; set the cover; lock or plate if unattended
  • Reinstate the highway or garden

Occupancy and other people

Driveways and pavements stay used. Write the diversion and that children cannot treat a ring stack as a fort.

Substances and COSHH

An SDS is an input, not a COSHH assessment. If these substances appear on the job, attach assessments that describe quantity, duration, who is exposed and the controls you will actually use:

  • Wet concrete
  • Sewage if a live connection
  • Diesel from pumps

How SafeForJob helps

  • Describe this job in plain English and get suggested activities, risks and method steps
  • Edit every line before you download or issue
  • Reuse a previous RAMS and catch old client or site names
  • Attach or create COSHH assessments where hazardous substances appear

What this page is not

This page is not HSE approval, legal advice or a substitute for competent judgement. It helps you draft a clearer manhole construction rams document for a named job. You remain responsible for reviewing and issuing it.

Related reading

See what a RAMS is, the free RAMS generator, and HSE guidance on managing risks.

Related pages

All rams by job · RAMS by trade · Free RAMS generator

Questions

Is this a sewer connection?
The connection may be in the same visit — attach that RAMS if you enter the public sewer.
Precast vs in-situ?
Write the actual — crane vs concrete burns.
Do I need confined-space?
If anyone’s breathing zone enters the shaft, yes.
Who owns the cover level?
The design — a proud cover is a trip.