Skip to content
SafeForJob

RAMS by job · UK

Linear heat cable RAMS

This is not a aspirating smoke RAMS. This job covers installing linear heat detection in a void or plant space, and the control that keeps people safe is a void survey and isolation of the circuit before the cable is pulled. If the RAMS never names the void, access and false trip into a live hall, a principal contractor will send it back.

Typical scope

  • A void survey and isolation of the circuit before the cable is pulled as a hold point
  • The void, access and false trip into a live hall named
  • Exclusion that actually holds
  • Sequence that cannot skip the critical control
  • Handover of residual hazards
  • Review before issue — not a stamp

Quick answer

A linear heat cable rams covers installing linear heat detection in a void or plant space on a named UK site. The critical control is a void survey and isolation of the circuit before the cable is pulled. Write the void, access and false trip into a live hall into the sequence — a pack that could describe any aspirating smoke RAMS will not survive a competent review.

Primary topic: linear heat cable rams. UK contractors — review every document before you issue it. SafeForJob does not replace competent judgement or HSE guidance.

What usually goes wrong

These are the operational gaps that make generic Word RAMS fail on the next site.

  • aspirating smoke RAMS reused

    Missing: a void survey and isolation of the circuit before the cable is pulled.

  • Critical control buried

    The void, access and false trip into a live hall belongs in the sequence.

  • Occupancy ignored

    The void, access and false trip into a live hall and that someone who did not read the pack will walk the exclusion.

Example

Linear heat cable on a named site

Built from one job description. You review and adjust every item before issuing it.

Job description

Installing linear heat detection in a void or plant space at Quay store, Elgin Dock, Elgin. Night 21:00–05:30. A void survey and isolation of the circuit before the cable is pulled; the void, access and false trip into a live hall; the void, access and false trip into a live hall and that someone who did not read the pack will walk the exclusion.

Activities identified

  • General site work
  • Electrical isolation
  • Manual handling
  • Occupied premises or public areas
  • Lone working

Method (10 steps)

  1. 1.Arrive and sign in. Arrive at Quay store, Elgin Dock, Elgin, report to the Elgin Dock Trust site contact, sign in and complete any site induction.
  2. 2.Brief the team. Brief all operatives on this RAMS, the COSHH assessments and the emergency arrangements. Record attendance.
  3. 3.Set up the work area. Set up barriers and signage around the work area and keep it clear of other people.
  4. 4.Isolate the electrical supply. Identify the relevant circuit, isolate, lock off and tag. Prove dead with an approved voltage indicator, proved before and after use.
  5. 5.Disconnect and remove existing equipment. Disconnect and remove the existing equipment. Lower or carry it using mechanical aids or team lifts as planned.
  6. 6.Install new equipment. Position and fix the new equipment to the manufacturer's instructions.
  7. 7.Carry out electrical work. Carry out the electrical work on the isolated circuit to BS 7671.
  8. 8.Remove isolation and re-energise. Confirm the work is complete and everyone is clear, remove locks and re-energise.
  9. 9.Clear up and remove waste. Clear the work area, remove waste from site (including recovered refrigerant and hazardous waste) and leave the area safe.
  10. 10.Hand over and sign out. Hand over to the Elgin Dock Trust site contact, report anything outstanding and sign out.

Main risks (4 in total)

Electric shock or burns

Residual Medium

Who: Operatives, building occupants

  • Work carried out dead — no live working
  • Safe isolation: isolate, lock off, tag, and prove dead with an approved voltage indicator (GS38) proved before and after
  • Only competent, qualified electricians carry out electrical work
  • Permit to work obtained where the site requires one
  • Personal locks and keys retained by the person working

Manual handling

Residual Medium

Who: Operatives

  • Use mechanical aids (trolleys, sack trucks, hoists) for heavy items
  • Team lifts for items too heavy or awkward for one person
  • Route planned and cleared before moving items
  • Operatives trained in safe lifting techniques
  • Gloves with good grip and safety footwear

Members of the public and building occupants

Residual Low

Who: Public, customers, staff, residents

  • Work area segregated with barriers and clear signage
  • Work timed for quieter periods where possible, agreed with the site
  • Tools and materials never left unattended in public areas
  • Site contact informed of work areas and any disruption

Lone working

Residual Low

Who: Lone operatives

  • Higher-risk tasks (work at height, live work, confined spaces) not carried out alone
  • Check-in procedure agreed with the office at set times
  • Mobile phone charged and signal checked on arrival

What to get right on this document

Critical control first

Put this hold point first: a void survey and isolation of the circuit before the cable is pulled.

Name the site facts

The void, access and false trip into a live hall

People who did not read the pack

The named site stays in use around this linear heat cable job

What this document has to cover

This is not a aspirating smoke RAMS. This job covers installing linear heat detection in a void or plant space, and the control that keeps people safe is a void survey and isolation of the circuit before the cable is pulled. If the RAMS never names the void, access and false trip into a live hall, a principal contractor will send it back.

A linear heat cable rams only holds up if it names the site, the people at risk, the critical control, and the order of work. Principal contractors reject paragraphs that could apply to any job of this type.

Typical hazards to assess on this job

  • People hurt if a void survey and isolation of the circuit before the cable is pulled is skipped on this linear heat cable job
  • Linear heat cable left open so a passer-by reaches the hazard
  • Wrong isolation so a sister linear heat cable stays live
  • Manual handling or dropped parts on this linear heat cable job
  • Weather, dust or a substance unique to installing linear heat detection in a void or plant space
  • The next crew inheriting an open linear heat cable hazard because handover was a text to nobody

Likelihood and severity change with occupancy, access, weather and other trades. Copying last month’s scores without looking at this site is how people get hurt.

A method sequence that actually protects people

Write the sequence so the critical control cannot be skipped. If isolation, edge protection or service location is the difference between safe and unsafe, it belongs before the work step — not in a general ‘PPE will be worn’ line.

  • Hold point: a void survey and isolation of the circuit before the cable is pulled
  • Brief the dutyholder on the void, access and false trip into a live hall
  • Set an exclusion that matches aspirating smoke RAMS failing on this site
  • Do the work to the sequence that keeps a void survey and isolation of the circuit before the cable is pulled first
  • Test or prove the critical control still holds
  • Handover residual linear heat cable hazards in writing

Occupancy and other people

The named site stays in use around this linear heat cable job. Write the void, access and false trip into a live hall and that someone who did not read the pack will walk the exclusion as occupancy control, not a hope.

Substances and COSHH

An SDS is an input, not a COSHH assessment. If these substances appear on the job, attach assessments that describe quantity, duration, who is exposed and the controls you will actually use:

  • Substances used while installing linear heat detection in a void or plant space
  • Cleaning wipes specified for the finish
  • Dust or residue from the opened plant

How SafeForJob helps

  • Describe this job in plain English and get suggested activities, risks and method steps
  • Edit every line before you download or issue
  • Reuse a previous RAMS and catch old client or site names
  • Attach or create COSHH assessments where hazardous substances appear

What this page is not

This page is not HSE approval, legal advice or a substitute for competent judgement. It helps you draft a clearer linear heat cable rams document for a named job. You remain responsible for reviewing and issuing it.

Related reading

See what a RAMS is, the free RAMS generator, and HSE guidance on managing risks.

Related pages

All rams by job · RAMS by trade · Free RAMS generator

Questions

Is this the same as a aspirating smoke RAMS?
No. A linear heat cable RAMS has to name the void, access and false trip into a live hall. A aspirating smoke RAMS will not survive a competent review.
Can we skip a void survey and isolation of the circuit before the cable is pulled?
No. A void survey and isolation of the circuit before the cable is pulled is the hold point. Write it before the work step.
Who writes the void, access and false trip into a live hall?
The competent person who issues this linear heat cable rams. A sticky note is not a handover.
Can AI issue this linear heat cable rams?
A tool can draft a linear heat cable pack. A competent person reviews and issues it for this site.