RAMS by job · UK
Lightning tape bond RAMS
This is not a lightning protection RAMS. This job covers bonding lightning tape on a roof or elevation, and the control that keeps people safe is isolation of nearby circuits and a documented access method before anyone leaves the ground. If the RAMS never names the access method, the drop zone and whether the roof plant stays live, a principal contractor will send it back.
Typical scope
- Isolation of nearby circuits and a documented access method before anyone leaves the ground as a hold point
- The access method, the drop zone and whether the roof plant stays live named
- Exclusion that actually holds
- Sequence that cannot skip the critical control
- Handover of residual hazards
- Review before issue — not a stamp
Quick answer
A lightning tape bond rams covers bonding lightning tape on a roof or elevation on a named UK site. The critical control is isolation of nearby circuits and a documented access method before anyone leaves the ground. Write the access method, the drop zone and whether the roof plant stays live into the sequence — a pack that could describe any lightning protection RAMS will not survive a competent review.
Primary topic: lightning tape bond rams. UK contractors — review every document before you issue it. SafeForJob does not replace competent judgement or HSE guidance.
What usually goes wrong
These are the operational gaps that make generic Word RAMS fail on the next site.
lightning protection RAMS reused
No isolation of nearby circuits and a documented access method before anyone leaves the ground.
Critical control buried
The access method, the drop zone and whether the roof plant stays live belongs in the sequence.
Occupancy ignored
The access method, the drop zone and whether the roof plant stays live and that someone who did not read the pack will walk the exclusion.
Example
Lightning tape bond on a named site
Built from one job description. You review and adjust every item before issuing it.
Job description
Bonding lightning tape on a roof or elevation at Plant room, Hexham Gate, Hexham. Saturday 07:00–17:00. Isolation of nearby circuits and a documented access method before anyone leaves the ground; the access method, the drop zone and whether the roof plant stays live; the access method, the drop zone and whether the roof plant stays live and that someone who did not read the pack will walk the exclusion.
Activities identified
- General site work
- Roof work
- Electrical isolation
Method (9 steps)
- 1.Arrive and sign in. Arrive at Plant room, Hexham Gate, Hexham, report to the Hexham Gate FM site contact, sign in and complete any site induction.
- 2.Brief the team. Brief all operatives on this RAMS, the COSHH assessments and the emergency arrangements. Record attendance.
- 3.Set up exclusion zone below. Establish an exclusion zone below the work area with barriers and signage before any work at height starts.
- 4.Isolate the electrical supply. Identify the relevant circuit, isolate, lock off and tag. Prove dead with an approved voltage indicator, proved before and after use.
- 5.Access the roof. Access the roof via the agreed route. Confirm edge protection is in place and identify any fragile areas before moving onto the roof.
- 6.Carry out electrical work. Carry out the electrical work on the isolated circuit to BS 7671.
- 7.Remove isolation and re-energise. Confirm the work is complete and everyone is clear, remove locks and re-energise.
- 8.Clear up and remove waste. Clear the work area, remove waste from site (including recovered refrigerant and hazardous waste) and leave the area safe.
- 9.Hand over and sign out. Hand over to the Hexham Gate FM site contact, report anything outstanding and sign out.
Main risks (5 in total)
Fall from roof edge
Residual MediumWho: Operatives
- Plan work to be done from below or from a MEWP where possible
- Edge protection (guard rails) or parapet of adequate height in place before work starts
- Safe access route to the roof agreed with the site; roof hatch secured open
- Where collective protection isn't possible, use a fall-restraint system with suitable anchors
- Work stops in high winds, ice or heavy rain
Fall through fragile roof or rooflight
Residual MediumWho: Operatives
- Treat all roof sheets and rooflights as fragile unless confirmed otherwise by the site
- Rooflights covered or protected with suitable mesh or barriers
- Staging or crawling boards used; no walking directly on sheets
- Safety netting or fall arrest below where required
Falling objects
Residual LowWho: People below, other trades, public
- Exclusion zone set up below the work area with barriers and signage
- Tools tethered when working at height; materials kept away from edges
- Banksman or second person controls the area during lifts and removals
- Hard hats worn in the exclusion zone
Adverse weather
Residual LowWho: Operatives
- Forecast checked before work; work at height stopped in high winds
- Breaks, water and shade in hot weather; warm clothing in cold
- Sun protection on exposed work in summer
+ 1 more risks in the full RAMS.
What to get right on this document
Critical control first
Put this hold point first: isolation of nearby circuits and a documented access method before anyone leaves the ground.
Name the site facts
The access method, the drop zone and whether the roof plant stays live
People who did not read the pack
The named site stays in use around this lightning tape bond job
What this document has to cover
This is not a lightning protection RAMS. This job covers bonding lightning tape on a roof or elevation, and the control that keeps people safe is isolation of nearby circuits and a documented access method before anyone leaves the ground. If the RAMS never names the access method, the drop zone and whether the roof plant stays live, a principal contractor will send it back.
A lightning tape bond rams only holds up if it names the site, the people at risk, the critical control, and the order of work. Principal contractors reject paragraphs that could apply to any job of this type.
Typical hazards to assess on this job
- People hurt if isolation of nearby circuits and a documented access method before anyone leaves the ground is skipped on this lightning tape bond job
- Lightning tape bond left open so a passer-by reaches the hazard
- Wrong isolation so a sister lightning tape bond stays live
- Manual handling or dropped parts on this lightning tape bond job
- Weather, dust or a substance unique to bonding lightning tape on a roof or elevation
- The next crew inheriting an open lightning tape bond hazard because handover was a text to nobody
Likelihood and severity change with occupancy, access, weather and other trades. Copying last month’s scores without looking at this site is how people get hurt.
A method sequence that actually protects people
Write the sequence so the critical control cannot be skipped. If isolation, edge protection or service location is the difference between safe and unsafe, it belongs before the work step — not in a general ‘PPE will be worn’ line.
- Hold point: isolation of nearby circuits and a documented access method before anyone leaves the ground
- Brief the dutyholder on the access method, the drop zone and whether the roof plant stays live
- Set an exclusion that matches lightning protection RAMS failing on this site
- Do the work to the sequence that keeps isolation of nearby circuits and a documented access method before anyone leaves the ground first
- Test or prove the critical control still holds
- Handover residual lightning tape bond hazards in writing
Occupancy and other people
The named site stays in use around this lightning tape bond job. Write the access method, the drop zone and whether the roof plant stays live and that someone who did not read the pack will walk the exclusion as occupancy control, not a hope.
Substances and COSHH
An SDS is an input, not a COSHH assessment. If these substances appear on the job, attach assessments that describe quantity, duration, who is exposed and the controls you will actually use:
- Substances used while bonding lightning tape on a roof or elevation
- Cleaning wipes specified for the finish
- Dust or residue from the opened plant
How SafeForJob helps
- Describe this job in plain English and get suggested activities, risks and method steps
- Edit every line before you download or issue
- Reuse a previous RAMS and catch old client or site names
- Attach or create COSHH assessments where hazardous substances appear
What this page is not
This page is not HSE approval, legal advice or a substitute for competent judgement. It helps you draft a clearer lightning tape bond rams document for a named job. You remain responsible for reviewing and issuing it.
Related reading
See what a RAMS is, the free RAMS generator, and HSE guidance on managing risks.
Related pages
- RAMS by tradeElectrical RAMSCreate a site-specific electrical RAMS online. Describe the job, review suggested risks like safe isolation and work at height, and download a professional PDF.
- GuidesWhat is a RAMS?RAMS means risk assessment and method statement — usually one site-specific pack for a construction or maintenance job. Practical UK guidance for contractors — with links to free tools.
- Method statementsMethod statement for electrical worksWrite a method statement for electrical works for a named UK site. Clear sequence, interfaces and controls — review before issue.
- RAMS by jobConsumer unit replacement RAMSCreate a consumer unit replacement rams for a named UK site. Suggested risks and method steps you review before download or issue.
- RAMS by jobEV charger installation RAMSCreate a ev charger installation rams for a named UK site. Suggested risks and method steps you review before download or issue.
- RAMS by jobLighting rewire RAMSCreate a lighting rewire rams for a named UK site. Suggested risks and method steps you review before download or issue.
- RAMS by jobEICR testing RAMSCreate a eicr method statement for a named UK site. Suggested risks and method steps you review before download or issue.
- RAMS by jobRooftop condenser replacement RAMSCreate a rooftop ac unit replacement rams for a named UK site. Suggested risks and method steps you review before download or issue.
- RAMS by jobSplit system installation RAMSCreate a split system installation rams for a named UK site. Suggested risks and method steps you review before download or issue.
Questions
- Is this the same as a lightning protection RAMS?
- No. A lightning tape bond RAMS has to name the access method, the drop zone and whether the roof plant stays live. A lightning protection RAMS will not survive a competent review.
- Can we skip isolation of nearby circuits and a documented access method before anyone leaves the ground?
- No. Isolation of nearby circuits and a documented access method before anyone leaves the ground is the hold point. Write it before the work step.
- Who writes the access method, the drop zone and whether the roof plant stays live?
- The competent person who issues this lightning tape bond rams. A sticky note is not a handover.
- Can AI issue this lightning tape bond rams?
- A tool can draft a lightning tape bond pack. A competent person reviews and issues it for this site.