Skip to content
SafeForJob

RAMS by job · UK

GRP / fibreglass roof RAMS

Fibreglass roofing is COSHH and height together. A torch-on RAMS that never mentions styrene, exclusion of ignition sources, or weather abort for resins will not pass.

Typical scope

  • Edge protection
  • Styrene COSHH and ventilation
  • Ignition exclusion
  • Weather abort
  • Catalyst handling
  • Hazardous waste

Quick answer

A GRP roof RAMS covers preparing a deck and laying glass-reinforced polyester on a named flat or porch roof. Styrene vapour, edge protection, and hot-or-chemical curing are the harms a felt-roof RAMS misses.

Primary topic: grp roof rams. UK contractors — review every document before you issue it. SafeForJob does not replace competent judgement or HSE guidance.

What usually goes wrong

These are the operational gaps that make generic Word RAMS fail on the next site.

  • Felt RAMS reused

    Burners and bitumen on a resin job.

  • Resin on a windy doorstep

    Vapour into the house.

  • Catalyst treated as water

    No COSHH.

Example

Porch roof over a front door

Built from one job description. You review and adjust every item before issuing it.

Job description

Lay a GRP system on the front porch at 9 Alma Road, Sheffield. Tower at the eaves, family using the back door, styrene COSHH, no smoking zone, rain abort, waste as hazardous.

Activities identified

  • General site work
  • Mobile tower or scaffold

Method (5 steps)

  1. 1.Arrive and sign in. Arrive at 9 Alma Road, Sheffield, report to the Private homeowner site contact, sign in and complete any site induction.
  2. 2.Brief the team. Brief all operatives on this RAMS, the COSHH assessments and the emergency arrangements. Record attendance.
  3. 3.Erect the tower. PASMA-trained operatives erect the mobile tower to the manufacturer's guide and inspect it before use.
  4. 4.Clear up and remove waste. Clear the work area, remove waste from site (including recovered refrigerant and hazardous waste) and leave the area safe.
  5. 5.Hand over and sign out. Hand over to the Private homeowner site contact, report anything outstanding and sign out.

Main risks (2 in total)

Fall from tower or scaffold, or collapse

Residual Medium

Who: Operatives, people nearby

  • Mobile towers erected by PASMA-trained persons to the manufacturer's guide
  • Scaffold erected by a competent scaffolder and tagged/inspected before use and every 7 days
  • Guard rails, toe boards and brick guards in place on working platforms
  • Castors locked and outriggers fitted; never moved while occupied

Falling objects

Residual Low

Who: People below, other trades, public

  • Exclusion zone set up below the work area with barriers and signage
  • Tools tethered when working at height; materials kept away from edges
  • Banksman or second person controls the area during lifts and removals
  • Hard hats worn in the exclusion zone

What to get right on this document

Name the resin system

Styrene and catalyst are the job.

Ventilate away from occupants

Not into the hallway.

Treat waste as hazardous

Rollers and tins are not general skip.

What this document has to cover

Fibreglass roofing is COSHH and height together. A torch-on RAMS that never mentions styrene, exclusion of ignition sources, or weather abort for resins will not pass.

A grp roof rams only holds up if it names the site, the people at risk, the critical control, and the order of work. Principal contractors reject paragraphs that could apply to any job of this type.

Typical hazards to assess on this job

  • Falls from the eaves or through a fragile deck
  • Inhalation of styrene and catalyst vapours
  • Skin burns from resin and peroxide catalysts
  • Fire — resins and solvents near ignition
  • Weather ruining the cure and creating a slip
  • Public and occupants smelling and breathing vapours

Likelihood and severity change with occupancy, access, weather and other trades. Copying last month’s scores without looking at this site is how people get hurt.

A method sequence that actually protects people

Write the sequence so the critical control cannot be skipped. If isolation, edge protection or service location is the difference between safe and unsafe, it belongs before the work step — not in a general ‘PPE will be worn’ line.

  • Confirm edge protection and that the deck is a working platform
  • Exclude ignition, brief occupants about odour, ventilate
  • Prep, tape and laminate to the system with COSHH controls
  • Do not leave wet resin as a slip; weather abort if rain is due
  • Trim, topcoat, collect waste and used rollers as hazardous
  • Handover cure time and no-go period for the client

Occupancy and other people

Porches sit over front doors. Occupants will walk through vapour if you do not time the job and ventilate away from the doorway.

Substances and COSHH

An SDS is an input, not a COSHH assessment. If these substances appear on the job, attach assessments that describe quantity, duration, who is exposed and the controls you will actually use:

  • Polyester resin and styrene
  • MEKP / peroxide catalyst
  • Acetone for tools
  • Glass mat fibres

How SafeForJob helps

  • Describe this job in plain English and get suggested activities, risks and method steps
  • Edit every line before you download or issue
  • Reuse a previous RAMS and catch old client or site names
  • Attach or create COSHH assessments where hazardous substances appear

What this page is not

This page is not HSE approval, legal advice or a substitute for competent judgement. It helps you draft a clearer grp roof rams document for a named job. You remain responsible for reviewing and issuing it.

Related reading

See what a RAMS is, the free RAMS generator, and HSE guidance on managing risks.

Related pages

All rams by job · RAMS by trade · Free RAMS generator

Questions

Is styrene a COSHH substance?
Yes — SDS, task duration, ventilation and RPE as assessed.
Can I do this in a school holiday only?
Odour and occupancy often force out-of-hours — write it.
What about existing asbestos felt?
Survey before grind-off.
Is this hot works?
Usually no flame, but ignition control still belongs because of vapours.