Fire board encasement RAMS
Encasement is a tested board system, not ‘two layers of plasterboard’. A drylining RAMS that never names the system, the steel schedule or how you close a box the same shift will fail the fire engineer.
Typical scope
- Specified system named
- Fixing centres as tested
- Dust control
- Same-shift close in occupation
- Penetrations detailed
- Escape kept
Quick answer
A fire-board encasement RAMS covers boxing steel or a service in a specified fire-resisting board system. The tested build-up, dust, and not leaving a steel unprotected overnight in an occupied building are the core.
Primary topic: fire board encasement rams. UK contractors — review every document before you issue it. SafeForJob does not replace competent judgement or HSE guidance.
What usually goes wrong
These are the operational gaps that make generic Word RAMS fail on the next site.
Drylining RAMS reused
No system, no steel schedule.
One layer because ‘it looks enough’
Not the tested build-up.
Beam left open Friday in an office
Strategy hole.
Example
Beam encasement over a live office
Built from one job description. You review and adjust every item before issuing it.
Job description
Encase three beams on level 2 at Greyfriars House, Leicester, Saturday. Specified board system, centres as tested, M-class cutting, each beam closed before 16:00, desks sheeted, no decorative wrap until photographed.
Activities identified
- General site work
- Power tools
- Painting and decorating
Method (6 steps)
- 1.Arrive and sign in. Arrive at Level 2, Greyfriars House, Leicester, report to the Greyfriars FM site contact, sign in and complete any site induction.
- 2.Brief the team. Brief all operatives on this RAMS, the COSHH assessments and the emergency arrangements. Record attendance.
- 3.Drill and fix. Mark out, then drill and fix using on-tool dust extraction. Check for hidden cables and pipes before drilling.
- 4.Prepare and decorate. Protect floors and furniture, prepare surfaces and apply coatings by brush or roller with the room ventilated.
- 5.Clear up and remove waste. Clear the work area, remove waste from site (including recovered refrigerant and hazardous waste) and leave the area safe.
- 6.Hand over and sign out. Hand over to the Greyfriars FM site contact, report anything outstanding and sign out.
Main risks (3 in total)
Hand and power tools
Residual LowWho: Operatives
- Battery or 110V tools used; no 230V tools on site without RCD protection
- Tools inspected before use and PAT tested where applicable
- Guards fitted and used as designed
- Eye protection and gloves suitable for the task
Noise and hand-arm vibration
Residual MediumWho: Operatives, people nearby
- Low-vibration, low-noise tools selected
- Trigger times limited and rotated between operatives
- Noisy work scheduled to reduce disruption to occupants
- Hearing protection worn where noise is high
Solvent vapours and spray mist
Residual MediumWho: Operatives, building occupants
- Water-based, low-VOC products used where possible
- Rooms ventilated; brush or roller preferred to spraying indoors
- No smoking or naked flames near solvent-based products
- Suitable RPE when spraying
What to get right on this document
Name the system
Layers and centres.
Close it the same shift
If people stay.
Dust is COSHH
Cut in a bay.
What this document has to cover
Encasement is a tested board system, not ‘two layers of plasterboard’. A drylining RAMS that never names the system, the steel schedule or how you close a box the same shift will fail the fire engineer.
A fire board encasement rams only holds up if it names the site, the people at risk, the critical control, and the order of work. Principal contractors reject paragraphs that could apply to any job of this type.
Typical hazards to assess on this job
- Fire protection missing because the system was substituted
- Dust from cutting boards in a live hall
- Falls from podiums while boarding a beam
- Unprotected steel left overnight in occupation
- Services buried without a fire-stopping detail
- Manual handling of boards in a stair used as an escape
Likelihood and severity change with occupancy, access, weather and other trades. Copying last month’s scores without looking at this site is how people get hurt.
A method sequence that actually protects people
Write the sequence so the critical control cannot be skipped. If isolation, edge protection or service location is the difference between safe and unsafe, it belongs before the work step — not in a general ‘PPE will be worn’ line.
- Confirm the specified system and steel schedule before a board is cut
- Set exclusion and dust control; keep an escape
- Fix to the tested centres and layers — no skipped noggins
- Close each member the same shift if the building stays occupied
- Fire-stop penetrations as the system
- Label and photograph; do not hide a thin box behind a decorative wrap
Occupancy and other people
Offices stay in use. Write the local exclusion and that an open box on a beam over a desk is a strategy hole until it is closed.
Substances and COSHH
An SDS is an input, not a COSHH assessment. If these substances appear on the job, attach assessments that describe quantity, duration, who is exposed and the controls you will actually use:
- Board fibres / dust
- Joint compounds and sealants of the system
- Fixing adhesives if used
How SafeForJob helps
- Describe this job in plain English and get suggested activities, risks and method steps
- Edit every line before you download or issue
- Reuse a previous RAMS and catch old client or site names
- Attach or create COSHH assessments where hazardous substances appear
What this page is not
This page is not HSE approval, legal advice or a substitute for competent judgement. It helps you draft a clearer fire board encasement rams document for a named job. You remain responsible for reviewing and issuing it.
Related reading
See what a RAMS is, the free RAMS generator, and HSE guidance on managing risks.
Related pages
- RAMS by tradeFire & security RAMSCreate RAMS for fire alarm, CCTV and access control installation: system isolations, ceiling work, occupied buildings. Review every suggestion before issue.
- GuidesWhat is a RAMS?RAMS means risk assessment and method statement — usually one site-specific pack for a construction or maintenance job. Practical UK guidance for contractors — with links to free tools.
- Method statementsFire alarm installation method statementWrite a fire alarm method statement for a named UK site. Clear sequence, interfaces and controls — review before issue.
- RAMS by jobConsumer unit replacement RAMSCreate a consumer unit replacement rams for a named UK site. Suggested risks and method steps you review before download or issue.
- RAMS by jobEV charger installation RAMSCreate a ev charger installation rams for a named UK site. Suggested risks and method steps you review before download or issue.
- RAMS by jobLighting rewire RAMSCreate a lighting rewire rams for a named UK site. Suggested risks and method steps you review before download or issue.
- RAMS by jobEICR testing RAMSCreate a eicr method statement for a named UK site. Suggested risks and method steps you review before download or issue.
- RAMS by jobRooftop condenser replacement RAMSCreate a rooftop ac unit replacement rams for a named UK site. Suggested risks and method steps you review before download or issue.
- RAMS by jobSplit system installation RAMSCreate a split system installation rams for a named UK site. Suggested risks and method steps you review before download or issue.
Questions
- Is this fire-stopping?
- Stopping is penetrations. This is encasement of a member.
- Can I use any fire board?
- Only the tested system on the schedule.
- Do I need a drylining RAMS too?
- Only if you are also lining rooms — do not blur the fire box.
- Who inspects?
- Usually the fire engineer or clerk of works against photos and labels.