RAMS by job · UK
Exterior floodlight mast RAMS
This is not a street-lighting RAMS. This job covers replacing or installing floodlights on a mast or high column, and the control that keeps people safe is isolation of the circuit and a documented access method before anyone leaves the ground. If the RAMS never names the access method, the drop zone and whether the pitch or car park stays open, a principal contractor will send it back.
Typical scope
- Access method named
- Wind limit written
- Circuit proved dead
- Hard drop zone
- Lamp waste bagged
- Column restored only when complete
Quick answer
A floodlight mast rams covers replacing or installing floodlights on a mast or high column on a named UK site. The critical control is isolation of the circuit and a documented access method before anyone leaves the ground. Write the access method, the drop zone and whether the pitch or car park stays open into the sequence — a pack that could describe any street-lighting RAMS will not survive a competent review.
Primary topic: floodlight mast rams. UK contractors — review every document before you issue it. SafeForJob does not replace competent judgement or HSE guidance.
What usually goes wrong
These are the operational gaps that make generic Word RAMS fail on the next site.
Street-lighting RAMS reused
No mast, no wind limit.
Tape as a drop zone
Cars still park.
HID in a black bag
Mercury and glass.
Example
Pitch mast swap after hours
Built from one job description. You review and adjust every item before issuing it.
Job description
Replace four floodlights on mast 3 at Riverside Playing Fields, Shrewsbury. Tuesday 20:00, MEWP, circuit locked, drop zone fenced, HID lamps in a UN drum, pitch closed until Thursday training.
Activities identified
- General site work
- Working at height (MEWP)
- Electrical isolation
- Manual handling
Method (11 steps)
- 1.Arrive and sign in. Arrive at Mast 3, Riverside Playing Fields, Shrewsbury, report to the Riverside Parish Council site contact, sign in and complete any site induction.
- 2.Brief the team. Brief all operatives on this RAMS, the COSHH assessments and the emergency arrangements. Record attendance.
- 3.Set up exclusion zone below. Establish an exclusion zone below the work area with barriers and signage before any work at height starts.
- 4.Isolate the electrical supply. Identify the relevant circuit, isolate, lock off and tag. Prove dead with an approved voltage indicator, proved before and after use.
- 5.Set up the MEWP. Check ground conditions, position the MEWP, deploy outriggers on spreader plates and complete pre-use checks.
- 6.Disconnect and remove existing equipment. Disconnect and remove the existing equipment. Lower or carry it using mechanical aids or team lifts as planned.
- 7.Install new equipment. Position and fix the new equipment to the manufacturer's instructions.
- 8.Carry out electrical work. Carry out the electrical work on the isolated circuit to BS 7671.
- 9.Remove isolation and re-energise. Confirm the work is complete and everyone is clear, remove locks and re-energise.
- 10.Clear up and remove waste. Clear the work area, remove waste from site (including recovered refrigerant and hazardous waste) and leave the area safe.
- 11.Hand over and sign out. Hand over to the Riverside Parish Council site contact, report anything outstanding and sign out.
Main risks (4 in total)
Fall from height (MEWP)
Residual MediumWho: Operatives, people below
- MEWP used instead of ladders for access to the work area
- Operator holds a valid IPAF (or equivalent) licence for the machine category
- Pre-use checks completed and recorded; thorough examination (LOLER) in date
- Ground conditions checked; outriggers on spreader plates where required
- Ground-level rescue plan in place and a trained person at ground level
- Full-body harness with short work-restraint lanyard clipped to the basket anchor (boom MEWPs)
Falling objects
Residual LowWho: People below, other trades, public
- Exclusion zone set up below the work area with barriers and signage
- Tools tethered when working at height; materials kept away from edges
- Banksman or second person controls the area during lifts and removals
- Hard hats worn in the exclusion zone
Electric shock or burns
Residual MediumWho: Operatives, building occupants
- Work carried out dead — no live working
- Safe isolation: isolate, lock off, tag, and prove dead with an approved voltage indicator (GS38) proved before and after
- Only competent, qualified electricians carry out electrical work
- Permit to work obtained where the site requires one
- Personal locks and keys retained by the person working
Manual handling
Residual MediumWho: Operatives
- Use mechanical aids (trolleys, sack trucks, hoists) for heavy items
- Team lifts for items too heavy or awkward for one person
- Route planned and cleared before moving items
- Operatives trained in safe lifting techniques
- Gloves with good grip and safety footwear
What to get right on this document
Access is the job
MEWP or climb — write it.
The circuit may feed more than one column
Prove this one.
Old lamps are waste
Licensed route.
What this document has to cover
This is not a street-lighting RAMS. This job covers replacing or installing floodlights on a mast or high column, and the control that keeps people safe is isolation of the circuit and a documented access method before anyone leaves the ground. If the RAMS never names the access method, the drop zone and whether the pitch or car park stays open, a principal contractor will send it back.
A floodlight mast rams only holds up if it names the site, the people at risk, the critical control, and the order of work. Principal contractors reject paragraphs that could apply to any job of this type.
Typical hazards to assess on this job
- Fall from a MEWP or climbing the mast
- Electric shock on a circuit that feeds more than one column
- Dropped luminaires striking people or cars below
- Wind exceeding the machine or mast limit
- Vehicle impact on the exclusion
- Old lamps as hazardous waste smashed into a stillage
Likelihood and severity change with occupancy, access, weather and other trades. Copying last month’s scores without looking at this site is how people get hurt.
A method sequence that actually protects people
Write the sequence so the critical control cannot be skipped. If isolation, edge protection or service location is the difference between safe and unsafe, it belongs before the work step — not in a general ‘PPE will be worn’ line.
- Confirm access method, wind limit and which circuit is isolated
- Hard exclusion and banksman for vehicles
- Isolate, lock and prove dead at the named column
- Swap or land fittings with lanyards; do not leave a live pendant
- Test and restore only the completed column
- Bag old lamps as hazardous waste
Occupancy and other people
Sports pitches and retail parks do not empty because you are at 12 m. Write the closed bay and that parents will walk under yellow tape for a match.
Substances and COSHH
An SDS is an input, not a COSHH assessment. If these substances appear on the job, attach assessments that describe quantity, duration, who is exposed and the controls you will actually use:
- Old HID lamps (hazardous waste)
- Cleaning wipes
- Paint touch-up on columns
How SafeForJob helps
- Describe this job in plain English and get suggested activities, risks and method steps
- Edit every line before you download or issue
- Reuse a previous RAMS and catch old client or site names
- Attach or create COSHH assessments where hazardous substances appear
What this page is not
This page is not HSE approval, legal advice or a substitute for competent judgement. It helps you draft a clearer floodlight mast rams document for a named job. You remain responsible for reviewing and issuing it.
Related reading
See what a RAMS is, the free RAMS generator, and HSE guidance on managing risks.
Related pages
- RAMS by tradeElectrical RAMSCreate a site-specific electrical RAMS online. Describe the job, review suggested risks like safe isolation and work at height, and download a professional PDF.
- GuidesWhat is a RAMS?RAMS means risk assessment and method statement — usually one site-specific pack for a construction or maintenance job. Practical UK guidance for contractors — with links to free tools.
- Method statementsMethod statement for electrical worksWrite a method statement for electrical works for a named UK site. Clear sequence, interfaces and controls — review before issue.
- RAMS by jobConsumer unit replacement RAMSCreate a consumer unit replacement rams for a named UK site. Suggested risks and method steps you review before download or issue.
- RAMS by jobEV charger installation RAMSCreate a ev charger installation rams for a named UK site. Suggested risks and method steps you review before download or issue.
- RAMS by jobLighting rewire RAMSCreate a lighting rewire rams for a named UK site. Suggested risks and method steps you review before download or issue.
- RAMS by jobEICR testing RAMSCreate a eicr method statement for a named UK site. Suggested risks and method steps you review before download or issue.
- RAMS by jobRooftop condenser replacement RAMSCreate a rooftop ac unit replacement rams for a named UK site. Suggested risks and method steps you review before download or issue.
- RAMS by jobSplit system installation RAMSCreate a split system installation rams for a named UK site. Suggested risks and method steps you review before download or issue.
Questions
- Is this street lighting?
- Related height and isolation. A mast over a pitch has a different drop zone and wind limit.
- Can we climb the mast?
- Only if the mast and competence allow it — write that method.
- Do I need a separate MEWP RAMS?
- Combine if the machine, ground and rescue are in this sequence.
- Who takes the old lamps?
- A licensed route — they are not general skip.