Skip to content
SafeForJob

RAMS by job · UK

Emergency lighting installation RAMS

Emergency lighting is often fitted in corridors, stairwells and plant rooms while the building stays open. The RAMS has to keep the escape route itself safe — not just the electrician.

Typical scope

  • Escape route kept open
  • Circuit isolation named
  • Height access stated
  • Function tests recorded
  • Out-of-hours briefing
  • Waste removed same day

Quick answer

An emergency lighting RAMS covers installing or testing self-contained or central-battery luminaires on a named site. It should include isolation, work at height, occupied-building controls and how escape routes stay usable.

Primary topic: emergency lighting installation rams. UK contractors — review every document before you issue it. SafeForJob does not replace competent judgement or HSE guidance.

What usually goes wrong

These are the operational gaps that make generic Word RAMS fail on the next site.

  • Whole floor isolated

    Staff walk a dark corridor because the method isolated too much.

  • Tower in the stairwell

    Access equipment becomes the obstruction the lighting is meant to serve.

  • Certificates later

    Tests promised after demob never happen.

Example

Corridor conversion in a live office

Built from one job description. You review and adjust every item before issuing it.

Job description

Replace maintained emergency luminaires on floors 2–3 at Quay House, Bristol. Work 18:00–22:00, keep the west stair as the live escape route, isolate lighting locally, test each fitting and restore before leaving.

Activities identified

  • General site work
  • Electrical isolation
  • Manual handling

Method (9 steps)

  1. 1.Arrive and sign in. Arrive at Quay House, Bristol, report to the Quay Facilities Ltd site contact, sign in and complete any site induction.
  2. 2.Brief the team. Brief all operatives on this RAMS, the COSHH assessments and the emergency arrangements. Record attendance.
  3. 3.Isolate the electrical supply. Identify the relevant circuit, isolate, lock off and tag. Prove dead with an approved voltage indicator, proved before and after use.
  4. 4.Disconnect and remove existing equipment. Disconnect and remove the existing equipment. Lower or carry it using mechanical aids or team lifts as planned.
  5. 5.Install new equipment. Position and fix the new equipment to the manufacturer's instructions.
  6. 6.Carry out electrical work. Carry out the electrical work on the isolated circuit to BS 7671.
  7. 7.Remove isolation and re-energise. Confirm the work is complete and everyone is clear, remove locks and re-energise.
  8. 8.Clear up and remove waste. Clear the work area, remove waste from site (including recovered refrigerant and hazardous waste) and leave the area safe.
  9. 9.Hand over and sign out. Hand over to the Quay Facilities Ltd site contact, report anything outstanding and sign out.

Main risks (2 in total)

Electric shock or burns

Residual Medium

Who: Operatives, building occupants

  • Work carried out dead — no live working
  • Safe isolation: isolate, lock off, tag, and prove dead with an approved voltage indicator (GS38) proved before and after
  • Only competent, qualified electricians carry out electrical work
  • Permit to work obtained where the site requires one
  • Personal locks and keys retained by the person working

Manual handling

Residual Medium

Who: Operatives

  • Use mechanical aids (trolleys, sack trucks, hoists) for heavy items
  • Team lifts for items too heavy or awkward for one person
  • Route planned and cleared before moving items
  • Operatives trained in safe lifting techniques
  • Gloves with good grip and safety footwear

What to get right on this document

Keep a way out

State which route stays lit and who is told.

Test as you go

Each fitting proved before the next bay.

Height that matches the stair

Podium vs steps vs MEWP named, not ‘suitable access’.

What this document has to cover

Emergency lighting is often fitted in corridors, stairwells and plant rooms while the building stays open. The RAMS has to keep the escape route itself safe — not just the electrician.

An emergency lighting installation rams only holds up if it names the site, the people at risk, the critical control, and the order of work. Principal contractors reject paragraphs that could apply to any job of this type.

Typical hazards to assess on this job

  • Fall from podium or steps in stairwells
  • Electric shock on maintained circuits
  • Blocking an escape route with tools or isolation
  • Dust and drilling into unknown substrates
  • Night or out-of-hours work fatigue
  • Public and staff using the corridor during the job

Likelihood and severity change with occupancy, access, weather and other trades. Copying last month’s scores without looking at this site is how people get hurt.

A method sequence that actually protects people

Write the sequence so the critical control cannot be skipped. If isolation, edge protection or service location is the difference between safe and unsafe, it belongs before the work step — not in a general ‘PPE will be worn’ line.

  • Agree phasing so one escape route remains available
  • Isolate only the circuits you are working on; label remaining lighting
  • Set a small exclusion in the immediate work bay, not the whole corridor
  • Install, terminate and function-test each luminaire before moving on
  • Restore normal lighting and remove waste the same shift
  • Handover test certificates and remaining defects

Occupancy and other people

Schools, offices and care homes stay occupied. Never isolate a whole floor’s lighting without an agreed alternative route and staff briefing.

Substances and COSHH

An SDS is an input, not a COSHH assessment. If these substances appear on the job, attach assessments that describe quantity, duration, who is exposed and the controls you will actually use:

  • Dust from masonry drilling
  • Battery packs in self-contained fittings
  • Solvent wipes for terminations

How SafeForJob helps

  • Describe this job in plain English and get suggested activities, risks and method steps
  • Edit every line before you download or issue
  • Reuse a previous RAMS and catch old client or site names
  • Attach or create COSHH assessments where hazardous substances appear

What this page is not

This page is not HSE approval, legal advice or a substitute for competent judgement. It helps you draft a clearer emergency lighting installation rams document for a named job. You remain responsible for reviewing and issuing it.

Related reading

See what a RAMS is, the free RAMS generator, and HSE guidance on managing risks.

Related pages

All rams by job · RAMS by trade · Free RAMS generator

Questions

Does testing need a separate RAMS?
Function testing can sit in the same RAMS if the method includes it. Live testing of other circuits should be called out.
What about central battery systems?
Include battery room access, ventilation and the higher stored-energy risk.
Do I need a hot works permit?
Not for typical LED swaps. Drilling and isolation still need controls.
Can this wait for a shutdown?
If the client can isolate a floor, say so. If not, write the occupied-corridor method.