Ducts are large, sharp and go in live ceilings. A generic HVAC RAMS that never mentions fire dampers, open ends, or how you keep the duct clean will fail a commissioning manager.

Typical scope

  • Fire dampers as specified
  • Open ends capped
  • Access named
  • Fire-stop same visit
  • Cleanliness / cap discipline
  • Damper records

Quick answer

A ductwork installation RAMS covers fabricating or installing rectangular and spiral ducts in ceiling voids and plant rooms. Height, manual handling, fire dampers, and cleanliness of the system are the core.

Primary topic: ductwork installation rams. UK contractors — review every document before you issue it. SafeForJob does not replace competent judgement or HSE guidance.

What usually goes wrong

These are the operational gaps that make generic Word RAMS fail on the next site.

  • Open spiral overnight

    Building dust in the system.

  • Damper ‘later’

    Fire strategy.

  • Tower blocking the corridor

    Escape.

Example

Level 4 spiral install out of hours

Built from one job description. You review and adjust every item before issuing it.

Job description

Install spiral supply ducts on level 4 at Harbour Hotel, Southampton, 22:00–06:00. Podiums, caps on every open end, fire dampers as drawn, fire-stop as we go, guests in rooms on level 3, corridor kept passable.

Activities identified

  • General site work
  • Ladders or stepladders
  • Manual handling
  • Occupied premises or public areas

Method (8 steps)

  1. 1.Arrive and sign in. Arrive at Harbour Hotel, Southampton, report to the Harbour Hotel Group site contact, sign in and complete any site induction.
  2. 2.Brief the team. Brief all operatives on this RAMS, the COSHH assessments and the emergency arrangements. Record attendance.
  3. 3.Set up the work area. Set up barriers and signage around the work area and keep it clear of other people.
  4. 4.Set up access equipment. Inspect and set up the podium or stepladder on firm, level ground in the work area.
  5. 5.Disconnect and remove existing equipment. Disconnect and remove the existing equipment. Lower or carry it using mechanical aids or team lifts as planned.
  6. 6.Install new equipment. Position and fix the new equipment to the manufacturer's instructions.
  7. 7.Clear up and remove waste. Clear the work area, remove waste from site (including recovered refrigerant and hazardous waste) and leave the area safe.
  8. 8.Hand over and sign out. Hand over to the Harbour Hotel Group site contact, report anything outstanding and sign out.

Main risks (3 in total)

Fall from ladders or stepladders

Residual Medium

Who: Operatives

  • Use a podium or mobile tower instead of a ladder where the task allows
  • Ladders only for short-duration (under 30 minutes), light work with three points of contact
  • Ladder inspected before use; industrial-grade (EN 131 professional) only
  • Ladder set on firm, level ground and footed or secured
  • No overreaching — move the ladder instead

Manual handling

Residual Medium

Who: Operatives

  • Use mechanical aids (trolleys, sack trucks, hoists) for heavy items
  • Team lifts for items too heavy or awkward for one person
  • Route planned and cleared before moving items
  • Operatives trained in safe lifting techniques
  • Gloves with good grip and safety footwear

Members of the public and building occupants

Residual Low

Who: Public, customers, staff, residents

  • Work area segregated with barriers and clear signage
  • Work timed for quieter periods where possible, agreed with the site
  • Tools and materials never left unattended in public areas
  • Site contact informed of work areas and any disruption

What to get right on this document

Cap as you go

Cleanliness is a safety and quality control.

Dampers in the sequence

Not a commissioning surprise.

Keep an escape

Access equipment is not allowed to own the corridor.

What this document has to cover

Ducts are large, sharp and go in live ceilings. A generic HVAC RAMS that never mentions fire dampers, open ends, or how you keep the duct clean will fail a commissioning manager.

A ductwork installation rams only holds up if it names the site, the people at risk, the critical control, and the order of work. Principal contractors reject paragraphs that could apply to any job of this type.

Typical hazards to assess on this job

  • Falls from podiums and towers in high voids
  • Cuts from sheet metal and falling sections
  • Manual handling of long ducts in corridors
  • Fire dampers installed wrongly or left open
  • Dust and debris left inside ducts that later serve occupied rooms
  • Other trades using your hanging wires as a step

Likelihood and severity change with occupancy, access, weather and other trades. Copying last month’s scores without looking at this site is how people get hurt.

A method sequence that actually protects people

Write the sequence so the critical control cannot be skipped. If isolation, edge protection or service location is the difference between safe and unsafe, it belongs before the work step — not in a general ‘PPE will be worn’ line.

  • Agree routes, supports and fire-damper locations from the drawings
  • Protect occupied rooms; set access equipment that leaves an escape
  • Hang supports, install ducts, fit dampers as specified
  • Cap open ends as you go so the system stays clean
  • Fire-stop penetrations the same visit
  • Clean, inspect and hand over damper drop-test records

Occupancy and other people

Live offices and hospitals cannot eat insulation dust from an open spiral. Local exclusion, caps on open ends, and out-of-hours for noisy cutting all belong in the method.

Substances and COSHH

An SDS is an input, not a COSHH assessment. If these substances appear on the job, attach assessments that describe quantity, duration, who is exposed and the controls you will actually use:

  • Sealants and solvents
  • Insulation fibres if wrapping
  • Cutting fluid / swarf on site-cut ducts

How SafeForJob helps

  • Describe this job in plain English and get suggested activities, risks and method steps
  • Edit every line before you download or issue
  • Reuse a previous RAMS and catch old client or site names
  • Attach or create COSHH assessments where hazardous substances appear

What this page is not

This page is not HSE approval, legal advice or a substitute for competent judgement. It helps you draft a clearer ductwork installation rams document for a named job. You remain responsible for reviewing and issuing it.

Related reading

See what a RAMS is, the free RAMS generator, and HSE guidance on managing risks.

Related pages

All rams by job · RAMS by trade · Free RAMS generator

Questions

Is this the same as kitchen extract?
Kitchen grease ducts have different fire and cleanliness rules — do not reuse this RAMS blindly.
Site-cut vs prefabricated?
Site cutting adds noise, swarf and sharper edges — write it if you will cut.
Who drop-tests dampers?
Name who and when; records go with handover.
Insulation wrap later?
Still fire-stop and cap now; wrap COSHH if fibres are used.