Skip to content
SafeForJob

RAMS by job · UK

Directional drilling RAMS

HDD is a steered bore, not a trench and not a diamond core. A vacuum-excavation RAMS that never mentions drill-rig exclusion, drilling fluid or how you stop a frac-out into a cellar will fail the asset owner.

Typical scope

  • Bore design and surveys
  • Entry/exit exclusion
  • Head tracked
  • Frac-out plan
  • Fluid as waste
  • Pits guarded

Quick answer

A directional-drilling RAMS covers a steered bore between named pits for a duct or pipe. Rig reaction, frac-out of mud, existing services and the public at both pits are the critical harms.

Primary topic: directional drilling rams. UK contractors — review every document before you issue it. SafeForJob does not replace competent judgement or HSE guidance.

What usually goes wrong

These are the operational gaps that make generic Word RAMS fail on the next site.

  • Trench RAMS reused

    No bore, no fluid.

  • Lost the head and kept pushing

    Strike.

  • Fluid to the kerb gully

    Pollution.

Example

HDD under a high street

Built from one job description. You review and adjust every item before issuing it.

Job description

Directionally drill a 40 m fibre duct under High Street, Chester, pit to pit. Utility surveys, tracked head, bentonite contained, frac-out plan for cellars, both pits guarded, shopkeepers briefed, no fluid to gullies, NRSWA TM.

Activities identified

  • General site work
  • Power tools
  • Dust-generating work
  • Fibre and data cabling

Method (7 steps)

  1. 1.Arrive and sign in. Arrive at High Street, Chester, report to the City Fibre Works site contact, sign in and complete any site induction.
  2. 2.Brief the team. Brief all operatives on this RAMS, the COSHH assessments and the emergency arrangements. Record attendance.
  3. 3.Drill and fix. Mark out, then drill and fix using on-tool dust extraction. Check for hidden cables and pipes before drilling.
  4. 4.Install and splice fibre. Route and secure cables, then cleave and splice fibres. Dispose of offcuts in the sharps container.
  5. 5.Test and commission. Test and commission the installation. Record results.
  6. 6.Clear up and remove waste. Clear the work area, remove waste from site (including recovered refrigerant and hazardous waste) and leave the area safe.
  7. 7.Hand over and sign out. Hand over to the City Fibre Works site contact, report anything outstanding and sign out.

Main risks (4 in total)

Hand and power tools

Residual Low

Who: Operatives

  • Battery or 110V tools used; no 230V tools on site without RCD protection
  • Tools inspected before use and PAT tested where applicable
  • Guards fitted and used as designed
  • Eye protection and gloves suitable for the task

Noise and hand-arm vibration

Residual Medium

Who: Operatives, people nearby

  • Low-vibration, low-noise tools selected
  • Trigger times limited and rotated between operatives
  • Noisy work scheduled to reduce disruption to occupants
  • Hearing protection worn where noise is high

Dust (including silica)

Residual Medium

Who: Operatives, people nearby

  • Use pre-formed holes, or methods that create less dust
  • On-tool extraction (M- or H-class) or water suppression when cutting or drilling
  • Clean up with an M-class vacuum — no dry sweeping
  • Face-fit tested RPE (FFP3 or equivalent) worn

Optical fibre — laser light and glass shards

Residual Low

Who: Engineers

  • Never look into fibre ends or connectors; treat all fibres as live
  • Fibre offcuts placed in a dedicated sharps container
  • Safety glasses worn when cleaving and splicing

What to get right on this document

Track the head

Lost location is a stop.

Frac-out is planned

Cellars and rivers.

Fluid is waste

Not a gully.

What this document has to cover

HDD is a steered bore, not a trench and not a diamond core. A vacuum-excavation RAMS that never mentions drill-rig exclusion, drilling fluid or how you stop a frac-out into a cellar will fail the asset owner.

A directional drilling rams only holds up if it names the site, the people at risk, the critical control, and the order of work. Principal contractors reject paragraphs that could apply to any job of this type.

Typical hazards to assess on this job

  • Rig reaction or rod strike injuring people at the entry
  • Strike of existing gas, HV or fibre along the bore
  • Frac-out of drilling fluid into a cellar, drain or river
  • Public at open pits
  • Manual handling of rods and reamers
  • Noise next to homes and hospitals

Likelihood and severity change with occupancy, access, weather and other trades. Copying last month’s scores without looking at this site is how people get hurt.

A method sequence that actually protects people

Write the sequence so the critical control cannot be skipped. If isolation, edge protection or service location is the difference between safe and unsafe, it belongs before the work step — not in a general ‘PPE will be worn’ line.

  • Confirm the bore design, service surveys and a frac-out plan before the rod turns
  • Set exclusion at entry and exit; pit-guard both ends
  • Drill to the designed profile; track the head; abort if you lose location
  • Contain fluid; legal disposal, not a gully or a brook
  • Pull the product; cap ends; do not leave a live pit
  • Reinstate; tell neighbours if a frac-out reached them

Occupancy and other people

Urban streets have cellars and basements on the line. Write who is told and that a shop cellar is occupancy, not a surprise mud bath.

Substances and COSHH

An SDS is an input, not a COSHH assessment. If these substances appear on the job, attach assessments that describe quantity, duration, who is exposed and the controls you will actually use:

  • Drilling fluid / bentonite
  • Diesel from the rig
  • Spoiled fluid (waste)

How SafeForJob helps

  • Describe this job in plain English and get suggested activities, risks and method steps
  • Edit every line before you download or issue
  • Reuse a previous RAMS and catch old client or site names
  • Attach or create COSHH assessments where hazardous substances appear

What this page is not

This page is not HSE approval, legal advice or a substitute for competent judgement. It helps you draft a clearer directional drilling rams document for a named job. You remain responsible for reviewing and issuing it.

Related reading

See what a RAMS is, the free RAMS generator, and HSE guidance on managing risks.

Related pages

All rams by job · RAMS by trade · Free RAMS generator

Questions

Is this diamond drilling?
No — HDD is a steered bore, not a core through a slab.
Vacuum instead?
Vac is a different exposure method. Use that RAMS if you are exposing, not boring.
Who owns the design profile?
The designer — do not steepen it to save a pit.
River crossing?
Add permits and a tighter frac-out plan — do not copy a street bore.