RAMS by job · UK
DC combiner box RAMS
This is not a solar dc isolator RAMS. This job covers installing a DC combiner on a live array, and the control that keeps people safe is DC isolation and prove-dead of the named strings before the box is opened. If the RAMS never names which strings stay live, the roof edge and first energise, a principal contractor will send it back.
Typical scope
- DC isolation and prove-dead of the named strings before the box is opened as a hold point
- Which strings stay live, the roof edge and first energise named
- Exclusion that actually holds
- Sequence that cannot skip the critical control
- Handover of residual hazards
- Review before issue — not a stamp
Quick answer
A dc combiner box rams covers installing a DC combiner on a live array on a named UK site. The critical control is DC isolation and prove-dead of the named strings before the box is opened. Write which strings stay live, the roof edge and first energise into the sequence — a pack that could describe any solar dc isolator RAMS will not survive a competent review.
Primary topic: dc combiner box rams. UK contractors — review every document before you issue it. SafeForJob does not replace competent judgement or HSE guidance.
What usually goes wrong
These are the operational gaps that make generic Word RAMS fail on the next site.
solar dc isolator RAMS reused
No DC isolation and prove-dead of the named strings before the box is opened.
Critical control buried
Which strings stay live, the roof edge and first energise belongs in the sequence.
Occupancy ignored
Which strings stay live, the roof edge and first energise and that someone who did not read the pack will walk the exclusion.
Example
DC combiner box on a named site
Built from one job description. You review and adjust every item before issuing it.
Job description
Installing a DC combiner on a live array at Pier store, Truro Harbour, Truro. Holiday week, staff return Friday. DC isolation and prove-dead of the named strings before the box is opened; which strings stay live, the roof edge and first energise; which strings stay live, the roof edge and first energise and that someone who did not read the pack will walk the exclusion.
Activities identified
- General site work
- Roof work
- Manual handling
- Occupied premises or public areas
Method (9 steps)
- 1.Arrive and sign in. Arrive at Pier store, Truro Harbour, Truro, report to the Truro Harbour FM site contact, sign in and complete any site induction.
- 2.Brief the team. Brief all operatives on this RAMS, the COSHH assessments and the emergency arrangements. Record attendance.
- 3.Set up the work area. Set up barriers and signage around the work area and keep it clear of other people.
- 4.Set up exclusion zone below. Establish an exclusion zone below the work area with barriers and signage before any work at height starts.
- 5.Access the roof. Access the roof via the agreed route. Confirm edge protection is in place and identify any fragile areas before moving onto the roof.
- 6.Disconnect and remove existing equipment. Disconnect and remove the existing equipment. Lower or carry it using mechanical aids or team lifts as planned.
- 7.Install new equipment. Position and fix the new equipment to the manufacturer's instructions.
- 8.Clear up and remove waste. Clear the work area, remove waste from site (including recovered refrigerant and hazardous waste) and leave the area safe.
- 9.Hand over and sign out. Hand over to the Truro Harbour FM site contact, report anything outstanding and sign out.
Main risks (6 in total)
Fall from roof edge
Residual MediumWho: Operatives
- Plan work to be done from below or from a MEWP where possible
- Edge protection (guard rails) or parapet of adequate height in place before work starts
- Safe access route to the roof agreed with the site; roof hatch secured open
- Where collective protection isn't possible, use a fall-restraint system with suitable anchors
- Work stops in high winds, ice or heavy rain
Fall through fragile roof or rooflight
Residual MediumWho: Operatives
- Treat all roof sheets and rooflights as fragile unless confirmed otherwise by the site
- Rooflights covered or protected with suitable mesh or barriers
- Staging or crawling boards used; no walking directly on sheets
- Safety netting or fall arrest below where required
Falling objects
Residual LowWho: People below, other trades, public
- Exclusion zone set up below the work area with barriers and signage
- Tools tethered when working at height; materials kept away from edges
- Banksman or second person controls the area during lifts and removals
- Hard hats worn in the exclusion zone
Adverse weather
Residual LowWho: Operatives
- Forecast checked before work; work at height stopped in high winds
- Breaks, water and shade in hot weather; warm clothing in cold
- Sun protection on exposed work in summer
+ 2 more risks in the full RAMS.
What to get right on this document
Critical control first
Put this hold point first: DC isolation and prove-dead of the named strings before the box is opened.
Name the site facts
Which strings stay live, the roof edge and first energise
People who did not read the pack
The named site stays in use around this dc combiner box job
What this document has to cover
This is not a solar dc isolator RAMS. This job covers installing a DC combiner on a live array, and the control that keeps people safe is DC isolation and prove-dead of the named strings before the box is opened. If the RAMS never names which strings stay live, the roof edge and first energise, a principal contractor will send it back.
A dc combiner box rams only holds up if it names the site, the people at risk, the critical control, and the order of work. Principal contractors reject paragraphs that could apply to any job of this type.
Typical hazards to assess on this job
- People hurt if DC isolation and prove-dead of the named strings before the box is opened is skipped on this dc combiner box job
- DC combiner box left open so a passer-by reaches the hazard
- Wrong isolation so a sister dc combiner box stays live
- Manual handling or dropped parts on this dc combiner box job
- Weather, dust or a substance unique to installing a DC combiner on a live array
- The next crew inheriting an open dc combiner box hazard because handover was a text to nobody
Likelihood and severity change with occupancy, access, weather and other trades. Copying last month’s scores without looking at this site is how people get hurt.
A method sequence that actually protects people
Write the sequence so the critical control cannot be skipped. If isolation, edge protection or service location is the difference between safe and unsafe, it belongs before the work step — not in a general ‘PPE will be worn’ line.
- Hold point: DC isolation and prove-dead of the named strings before the box is opened
- Brief the dutyholder on which strings stay live, the roof edge and first energise
- Set an exclusion that matches solar dc isolator RAMS failing on this site
- Do the work to the sequence that keeps DC isolation and prove-dead of the named strings before the box is opened first
- Test or prove the critical control still holds
- Handover residual dc combiner box hazards in writing
Occupancy and other people
The named site stays in use around this dc combiner box job. Write which strings stay live, the roof edge and first energise and that someone who did not read the pack will walk the exclusion as occupancy control, not a hope.
Substances and COSHH
An SDS is an input, not a COSHH assessment. If these substances appear on the job, attach assessments that describe quantity, duration, who is exposed and the controls you will actually use:
- Substances used while installing a DC combiner on a live array
- Cleaning wipes specified for the finish
- Dust or residue from the opened plant
How SafeForJob helps
- Describe this job in plain English and get suggested activities, risks and method steps
- Edit every line before you download or issue
- Reuse a previous RAMS and catch old client or site names
- Attach or create COSHH assessments where hazardous substances appear
What this page is not
This page is not HSE approval, legal advice or a substitute for competent judgement. It helps you draft a clearer dc combiner box rams document for a named job. You remain responsible for reviewing and issuing it.
Related reading
See what a RAMS is, the free RAMS generator, and HSE guidance on managing risks.
Related pages
- RAMS by tradeSolar PV RAMSCreate solar pv rams online for UK sites. Suggested risks and method steps matched to the job — you review every item before issue.
- GuidesWhat is a RAMS?RAMS means risk assessment and method statement — usually one site-specific pack for a construction or maintenance job. Practical UK guidance for contractors — with links to free tools.
- Method statementsSolar PV method statementWrite a solar panel method statement for a named UK site. Clear sequence, interfaces and controls — review before issue.
- RAMS by jobConsumer unit replacement RAMSCreate a consumer unit replacement rams for a named UK site. Suggested risks and method steps you review before download or issue.
- RAMS by jobEV charger installation RAMSCreate a ev charger installation rams for a named UK site. Suggested risks and method steps you review before download or issue.
- RAMS by jobLighting rewire RAMSCreate a lighting rewire rams for a named UK site. Suggested risks and method steps you review before download or issue.
- RAMS by jobEICR testing RAMSCreate a eicr method statement for a named UK site. Suggested risks and method steps you review before download or issue.
- RAMS by jobRooftop condenser replacement RAMSCreate a rooftop ac unit replacement rams for a named UK site. Suggested risks and method steps you review before download or issue.
- RAMS by jobSplit system installation RAMSCreate a split system installation rams for a named UK site. Suggested risks and method steps you review before download or issue.
Questions
- Is this the same as a solar dc isolator RAMS?
- No. A dc combiner box RAMS has to name which strings stay live, the roof edge and first energise. A solar dc isolator RAMS will not survive a competent review.
- Can we skip DC isolation and prove-dead of the named strings before the box is opened?
- No. DC isolation and prove-dead of the named strings before the box is opened is the hold point. Write it before the work step.
- Who writes which strings stay live, the roof edge and first energise?
- The competent person who issues this dc combiner box rams. A sticky note is not a handover.
- Can AI issue this dc combiner box rams?
- A tool can draft a dc combiner box pack. A competent person reviews and issues it for this site.