Skip to content
SafeForJob

RAMS by job · UK

Car-park deck lighting RAMS

This is not street lighting and not a warehouse high-bay. You are in a live car park with exhaust, reversing cars and a concrete soffit that may hide services. A street-column RAMS will miss the deck traffic plan.

Typical scope

  • Deck or lane closed
  • Circuit isolated
  • Scan before drill
  • Platform named
  • Zone-by-zone restore
  • Pedestrian route that is not a traffic lane

Quick answer

A car-park deck lighting RAMS covers installing or replacing luminaires on a multi-storey or podium deck. Vehicles still moving, work at height under a low soffit, and water on the deck are the critical harms.

Primary topic: car park lighting rams. UK contractors — review every document before you issue it. SafeForJob does not replace competent judgement or HSE guidance.

What usually goes wrong

These are the operational gaps that make generic Word RAMS fail on the next site.

  • Street lighting RAMS reused

    No deck traffic.

  • Van roof as the platform

    No access plan.

  • Whole park dark at once

    No zone restore.

Example

Level-2 deck lights over a retail park

Built from one job description. You review and adjust every item before issuing it.

Job description

Replace 40 soffit lights on level 2 at Riverside MSCP, Preston. Sunday morning, level 2 closed, marshal at the ramp, lighting isolated, GPR before new fixings, scissor at low height, levels 1 and 3 stay open.

Activities identified

  • General site work
  • Roof work
  • Electrical isolation
  • Manual handling

Method (11 steps)

  1. 1.Arrive and sign in. Arrive at Level 2, Riverside MSCP, Preston, report to the Riverside Retail FM site contact, sign in and complete any site induction.
  2. 2.Brief the team. Brief all operatives on this RAMS, the COSHH assessments and the emergency arrangements. Record attendance.
  3. 3.Set up exclusion zone below. Establish an exclusion zone below the work area with barriers and signage before any work at height starts.
  4. 4.Isolate the electrical supply. Identify the relevant circuit, isolate, lock off and tag. Prove dead with an approved voltage indicator, proved before and after use.
  5. 5.Access the roof. Access the roof via the agreed route. Confirm edge protection is in place and identify any fragile areas before moving onto the roof.
  6. 6.Disconnect and remove existing equipment. Disconnect and remove the existing equipment. Lower or carry it using mechanical aids or team lifts as planned.
  7. 7.Install new equipment. Position and fix the new equipment to the manufacturer's instructions.
  8. 8.Carry out electrical work. Carry out the electrical work on the isolated circuit to BS 7671.
  9. 9.Remove isolation and re-energise. Confirm the work is complete and everyone is clear, remove locks and re-energise.
  10. 10.Clear up and remove waste. Clear the work area, remove waste from site (including recovered refrigerant and hazardous waste) and leave the area safe.
  11. 11.Hand over and sign out. Hand over to the Riverside Retail FM site contact, report anything outstanding and sign out.

Main risks (6 in total)

Fall from roof edge

Residual Medium

Who: Operatives

  • Plan work to be done from below or from a MEWP where possible
  • Edge protection (guard rails) or parapet of adequate height in place before work starts
  • Safe access route to the roof agreed with the site; roof hatch secured open
  • Where collective protection isn't possible, use a fall-restraint system with suitable anchors
  • Work stops in high winds, ice or heavy rain

Fall through fragile roof or rooflight

Residual Medium

Who: Operatives

  • Treat all roof sheets and rooflights as fragile unless confirmed otherwise by the site
  • Rooflights covered or protected with suitable mesh or barriers
  • Staging or crawling boards used; no walking directly on sheets
  • Safety netting or fall arrest below where required

Falling objects

Residual Low

Who: People below, other trades, public

  • Exclusion zone set up below the work area with barriers and signage
  • Tools tethered when working at height; materials kept away from edges
  • Banksman or second person controls the area during lifts and removals
  • Hard hats worn in the exclusion zone

Adverse weather

Residual Low

Who: Operatives

  • Forecast checked before work; work at height stopped in high winds
  • Breaks, water and shade in hot weather; warm clothing in cold
  • Sun protection on exposed work in summer

+ 2 more risks in the full RAMS.

What to get right on this document

Cars are the occupancy

Close a zone, marshal it.

The soffit hides services

Scan, then drill.

Keep a lit way out

Restore by zone.

What this document has to cover

This is not street lighting and not a warehouse high-bay. You are in a live car park with exhaust, reversing cars and a concrete soffit that may hide services. A street-column RAMS will miss the deck traffic plan.

A car park lighting rams only holds up if it names the site, the people at risk, the critical control, and the order of work. Principal contractors reject paragraphs that could apply to any job of this type.

Typical hazards to assess on this job

  • Struck by a reversing vehicle on the deck
  • Fall from a podium or low-level MEWP under a soffit
  • Electric shock on lighting that shares a wet deck circuit
  • Dropped fittings onto a windscreen or person
  • Drilling into post-tensioned slabs or hidden services
  • Public pedestrians using the same ramp

Likelihood and severity change with occupancy, access, weather and other trades. Copying last month’s scores without looking at this site is how people get hurt.

A method sequence that actually protects people

Write the sequence so the critical control cannot be skipped. If isolation, edge protection or service location is the difference between safe and unsafe, it belongs before the work step — not in a general ‘PPE will be worn’ line.

  • Set traffic management and a closed deck or lane before the first ladder thought
  • Isolate and prove dead the lighting circuit; scan before drill
  • Access from the named platform — not a roof of a van
  • Fix, terminate, gasket against deck water
  • Test and restore one zone at a time so the rest of the park stays lit
  • Take down TM; leave the deck clear of off-cuts

Occupancy and other people

Shoppers and residents still park. Write the closed zone, the marshal, and that you do not funnel pedestrians behind a reversing SUV.

Substances and COSHH

An SDS is an input, not a COSHH assessment. If these substances appear on the job, attach assessments that describe quantity, duration, who is exposed and the controls you will actually use:

  • Sealants at deck penetrations
  • Cleaning solvents on gear trays
  • Concrete dust from drillings

How SafeForJob helps

  • Describe this job in plain English and get suggested activities, risks and method steps
  • Edit every line before you download or issue
  • Reuse a previous RAMS and catch old client or site names
  • Attach or create COSHH assessments where hazardous substances appear

What this page is not

This page is not HSE approval, legal advice or a substitute for competent judgement. It helps you draft a clearer car park lighting rams document for a named job. You remain responsible for reviewing and issuing it.

Related reading

See what a RAMS is, the free RAMS generator, and HSE guidance on managing risks.

Related pages

All rams by job · RAMS by trade · Free RAMS generator

Questions

Is this NRSWA?
Only if you occupy the adopted highway. A private MSCP still needs TM for cars.
Post-tensioned deck?
Designer go-ahead before new holes — tendons are not a guess.
Can I use a ladder between cars?
Not as the method. Close the bays.
Emergency lighting on the same circuit?
If you isolate it, write the temporary escape lighting.