Skip to content
SafeForJob

RAMS by job · UK

Car-park deck coating RAMS

This is a trafficked waterproofing system, not a balcony paint. A resin-floor RAMS that never mentions ramps, live cars or how you keep an escape stair free of wet resin will fail the car-park operator.

Typical scope

  • Phased deck closure
  • Extract on grind
  • Named chemistry
  • Traffic time, not guesswork
  • Stairs kept clean
  • Adjoining occupancy briefed

Quick answer

A car-park deck-coating RAMS covers preparing and applying a waterproof wear-coat on a named MSCP or podium deck. Vehicles, silica from prep, resin COSHH and not trapping cars on an upper deck are the core.

Primary topic: car park deck coating rams. UK contractors — review every document before you issue it. SafeForJob does not replace competent judgement or HSE guidance.

What usually goes wrong

These are the operational gaps that make generic Word RAMS fail on the next site.

  • Balcony RAMS reused

    No cars, no ramps.

  • Whole ramp coated at once

    Cars trapped.

  • MMA next to a cinema matinee

    Odour.

Example

Level-3 wear-coat on a retail MSCP

Built from one job description. You review and adjust every item before issuing it.

Job description

Grind and coat level 3 at Riverside MSCP, Preston, Friday 20:00–Sunday 16:00. Level 3 closed, ramps 2 and 4 stay open, on-tool extract, solvent-free epoxy, traffic time Monday 06:00, cinema told, stairs sheeted.

Activities identified

  • General site work
  • Hot works
  • Power tools
  • Using chemicals or products

Method (8 steps)

  1. 1.Arrive and sign in. Arrive at Level 3, Riverside MSCP, Preston, report to the Riverside Retail FM site contact, sign in and complete any site induction.
  2. 2.Brief the team. Brief all operatives on this RAMS, the COSHH assessments and the emergency arrangements. Record attendance.
  3. 3.Obtain hot works permit. Obtain a hot works permit from the site. Remove or protect combustibles and place an extinguisher at the point of work.
  4. 4.Drill and fix. Mark out, then drill and fix using on-tool dust extraction. Check for hidden cables and pipes before drilling.
  5. 5.Braze joints. Braze joints under the hot works permit with nitrogen purge. Maintain the fire watch during and after the work.
  6. 6.Apply products. Apply products as described on the Safety Data Sheet and COSHH assessment, with ventilation and the specified PPE.
  7. 7.Clear up and remove waste. Clear the work area, remove waste from site (including recovered refrigerant and hazardous waste) and leave the area safe.
  8. 8.Hand over and sign out. Hand over to the Riverside Retail FM site contact, report anything outstanding and sign out.

Main risks (5 in total)

Fire from hot works

Residual Medium

Who: Operatives, building occupants

  • Use cold-work methods (press-fit, mechanical joints) instead of hot works where possible
  • Hot works permit obtained from the site before starting
  • Combustibles removed or protected with fire-resistant blankets
  • Suitable fire extinguisher at the point of work
  • Fire watch maintained during work and for at least 60 minutes after finishing
  • Fire-resistant gloves and eye/face protection

Fumes from hot works

Residual Medium

Who: Operatives, people nearby

  • Work in well-ventilated areas; local exhaust ventilation for welding
  • Keep the head out of the fume plume
  • Suitable RPE (face-fit tested) where ventilation isn't adequate

Hand and power tools

Residual Low

Who: Operatives

  • Battery or 110V tools used; no 230V tools on site without RCD protection
  • Tools inspected before use and PAT tested where applicable
  • Guards fitted and used as designed
  • Eye protection and gloves suitable for the task

Noise and hand-arm vibration

Residual Medium

Who: Operatives, people nearby

  • Low-vibration, low-noise tools selected
  • Trigger times limited and rotated between operatives
  • Noisy work scheduled to reduce disruption to occupants
  • Hearing protection worn where noise is high

+ 1 more risks in the full RAMS.

What to get right on this document

Leave a way out

Phased closure.

Chemistry is named

MMA vs epoxy.

Traffic time is a number

From the system, not a finger.

What this document has to cover

This is a trafficked waterproofing system, not a balcony paint. A resin-floor RAMS that never mentions ramps, live cars or how you keep an escape stair free of wet resin will fail the car-park operator.

A car park deck coating rams only holds up if it names the site, the people at risk, the critical control, and the order of work. Principal contractors reject paragraphs that could apply to any job of this type.

Typical hazards to assess on this job

  • Struck by a car on a half-closed deck
  • Silica from grinding the slab
  • Sensitisation from epoxy or MMA vapours
  • Slips on wet coat
  • Cars trapped on an upper deck with a wet ramp
  • Odour into shops or flats adjoining the podium

Likelihood and severity change with occupancy, access, weather and other trades. Copying last month’s scores without looking at this site is how people get hurt.

A method sequence that actually protects people

Write the sequence so the critical control cannot be skipped. If isolation, edge protection or service location is the difference between safe and unsafe, it belongs before the work step — not in a general ‘PPE will be worn’ line.

  • Agree a phased closure so ramps and exits still work
  • Grind with extract; protect drains
  • Apply the specified system; ignition control if MMA
  • Exclude until the traffic time — not ‘when it looks dry’
  • Keep stairs and pedestrian routes free of resin
  • Ventilate away from shops and flats; brief them

Occupancy and other people

MSCPs stay trading. Write the closed zone, the remaining exit, and that MMA on a Saturday next to a cinema is an occupancy problem.

Substances and COSHH

An SDS is an input, not a COSHH assessment. If these substances appear on the job, attach assessments that describe quantity, duration, who is exposed and the controls you will actually use:

  • Epoxy or MMA (name the actual)
  • Silica from grind
  • Primers and solvents

How SafeForJob helps

  • Describe this job in plain English and get suggested activities, risks and method steps
  • Edit every line before you download or issue
  • Reuse a previous RAMS and catch old client or site names
  • Attach or create COSHH assessments where hazardous substances appear

What this page is not

This page is not HSE approval, legal advice or a substitute for competent judgement. It helps you draft a clearer car park deck coating rams document for a named job. You remain responsible for reviewing and issuing it.

Related reading

See what a RAMS is, the free RAMS generator, and HSE guidance on managing risks.

Related pages

All rams by job · RAMS by trade · Free RAMS generator

Questions

Is this resin flooring?
Related chemistry, different traffic, ramps and cars. Use this RAMS.
MMA vs epoxy?
MMA is typically stronger odour and ignition — do not mix the methods.
Can I coat the whole park?
Not unless you have another exit — write the phase.
Drains on the deck?
Protect them — resin in a gully is a pollution and a blocked drain.