Skip to content
SafeForJob

RAMS by job · UK

Blown fibre RAMS

Blowing is a stored-energy duct job, not a pull. A CAT6 RAMS that never mentions the compressor, a flying end in a chamber or how you stop the public at a footway box will fail.

Typical scope

  • Catcher at the far end
  • Specified blow pressure
  • Boxes excluded
  • No unplanned entry
  • Ends controlled
  • Compressor off the footway after

Quick answer

A blown-fibre RAMS covers blowing fibre through a duct between named points. Compressed air, blowing-head reaction, and not blowing into an occupied chamber without a plan are the usual harms.

Primary topic: blown fibre rams. UK contractors — review every document before you issue it. SafeForJob does not replace competent judgement or HSE guidance.

What usually goes wrong

These are the operational gaps that make generic Word RAMS fail on the next site.

  • Pull RAMS reused

    No air, no catcher.

  • Blown with nobody at the far end

    Fibre in a live chamber, uncaught.

  • Compressor left on a crossing

    Public.

Example

Blow between two street boxes

Built from one job description. You review and adjust every item before issuing it.

Job description

Blow 24-fibre from cabinet CF-12 to CF-18, Station Approach, Derby. Catcher at CF-18, specified pressure, both boxes excluded, no chamber entry, compressor off the crossing, boxes locked, school route clear by 15:00.

Activities identified

  • General site work
  • Confined space
  • Occupied premises or public areas
  • Fibre and data cabling

Method (8 steps)

  1. 1.Arrive and sign in. Arrive at Station Approach, Derby, report to the City Fibre Works site contact, sign in and complete any site induction.
  2. 2.Brief the team. Brief all operatives on this RAMS, the COSHH assessments and the emergency arrangements. Record attendance.
  3. 3.Set up the work area. Set up barriers and signage around the work area and keep it clear of other people.
  4. 4.Confined space permit and gas test. Obtain the permit to work, test the atmosphere and confirm rescue arrangements before anyone enters.
  5. 5.Install and splice fibre. Route and secure cables, then cleave and splice fibres. Dispose of offcuts in the sharps container.
  6. 6.Test and commission. Test and commission the installation. Record results.
  7. 7.Clear up and remove waste. Clear the work area, remove waste from site (including recovered refrigerant and hazardous waste) and leave the area safe.
  8. 8.Hand over and sign out. Hand over to the City Fibre Works site contact, report anything outstanding and sign out.

Main risks (3 in total)

Confined space

Residual Medium

Who: Operatives, rescuers

  • Avoid entry — do the work from outside where possible
  • Permit to work and confined space trained operatives
  • Atmosphere tested before and during entry with a calibrated gas monitor
  • Emergency rescue arrangements in place before entry

Members of the public and building occupants

Residual Low

Who: Public, customers, staff, residents

  • Work area segregated with barriers and clear signage
  • Work timed for quieter periods where possible, agreed with the site
  • Tools and materials never left unattended in public areas
  • Site contact informed of work areas and any disruption

Optical fibre — laser light and glass shards

Residual Low

Who: Engineers

  • Never look into fibre ends or connectors; treat all fibres as live
  • Fibre offcuts placed in a dedicated sharps container
  • Safety glasses worn when cleaving and splicing

What to get right on this document

A catcher is the method

Both ends.

Pressure is specified

Do not crank it.

Boxes are public holes

Exclude and lock.

What this document has to cover

Blowing is a stored-energy duct job, not a pull. A CAT6 RAMS that never mentions the compressor, a flying end in a chamber or how you stop the public at a footway box will fail.

A blown fibre rams only holds up if it names the site, the people at risk, the critical control, and the order of work. Principal contractors reject paragraphs that could apply to any job of this type.

Typical hazards to assess on this job

  • Compressed-air injury at the blowing head or an open end
  • Confined-space gases if you enter a chamber to catch fibre
  • Public at an open footway box
  • Flying fibre end striking eyes
  • Noise of the compressor next to homes
  • Damage to existing live fibre in a shared duct

Likelihood and severity change with occupancy, access, weather and other trades. Copying last month’s scores without looking at this site is how people get hurt.

A method sequence that actually protects people

Write the sequence so the critical control cannot be skipped. If isolation, edge protection or service location is the difference between safe and unsafe, it belongs before the work step — not in a general ‘PPE will be worn’ line.

  • Confirm duct integrity and a catcher at the far end before you pressurise
  • Set exclusion at both boxes; no unplanned chamber entry
  • Blow to the specified pressure; abort if the duct blocks
  • Catch and coil; do not let an end whip in a public box
  • Lock boxes; take the compressor off the footway
  • Test and label; brief the occupier if you have been in a building

Occupancy and other people

Streets stay open. Write both boxes and that a child will watch the ‘hose’ unless you exclude them.

Substances and COSHH

An SDS is an input, not a COSHH assessment. If these substances appear on the job, attach assessments that describe quantity, duration, who is exposed and the controls you will actually use:

  • Compressed air (energy, not a substance story)
  • Duct lubricant if specified
  • Resin at joints if used

How SafeForJob helps

  • Describe this job in plain English and get suggested activities, risks and method steps
  • Edit every line before you download or issue
  • Reuse a previous RAMS and catch old client or site names
  • Attach or create COSHH assessments where hazardous substances appear

What this page is not

This page is not HSE approval, legal advice or a substitute for competent judgement. It helps you draft a clearer blown fibre rams document for a named job. You remain responsible for reviewing and issuing it.

Related reading

See what a RAMS is, the free RAMS generator, and HSE guidance on managing risks.

Related pages

All rams by job · RAMS by trade · Free RAMS generator

Questions

Is this a fibre drop into a house?
A drop is a different internal finish. This is the duct blow.
Can I pull instead?
Different method — do not copy blow pressures onto a pull.
Shared duct with power?
Stop and get the asset owner — do not blow blind.
Who owns the compressor exclusion?
You — it is plant on a footway.